CVE-2022-1374

CRITICAL 9.8EPSS 71%

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_…

Mitigation

  • Upgrade DIAEnergie to 1.8.02.004 or later.
  • Vendor workaround: Delta also suggests users:
  • Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.
  • Locate control system networks and remote devices behind firewalls and isolate them from the business network.
  • Use an application firewall that can detect attacks against “Path Traversal” and “SQL Injection” weakness.
  • Never connect programming software to any network other than the network intended for that device.
  • When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices

Who should check

  • Anyone running Delta Electronics DIAEnergie >= unspecified, < 1.8.02.004

Vulnerability facts

Affected
Delta Electronics DIAEnergie >= unspecified, < 1.8.02.004
Fixed in
Delta Electronics DIAEnergie 1.8.02.004
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
9.8 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
1.31% chance of exploitation in 30 days (percentile 71, 2026-11-26)
CWE
CWE-89
Published
Modified

Description

Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_unHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.

Affected and fixed versions

Package / productAffectedFixedSource
Delta Electronics DIAEnergie>= unspecified, < 1.8.02.004—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2022-1374. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-1374.md
Affected: Delta Electronics DIAEnergie >= unspecified, < 1.8.02.004
Fixed in: Delta Electronics DIAEnergie 1.8.02.004

Steps:
1. Search this machine and project for Delta Electronics DIAEnergie: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2022-1374 being exploited?

There is no confirmed exploitation: CVE-2022-1374 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.31% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2022-1374?

Critical: CVSS 9.8 (v3.1, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2022-1374?

Delta Electronics DIAEnergie >= unspecified, < 1.8.02.004.

Is there a fix for CVE-2022-1374?

Yes. Fixed in Delta Electronics DIAEnergie 1.8.02.004. Upgrade DIAEnergie to 1.8.02.004 or later. Vendor workaround: Delta also suggests users: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolate them from the business network. Use an application firewall that can detect attacks against “Path Traversal” and “SQL Injection” weakness. Never connect programming software to any network other than the network intended for that device. When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices

How do I check if I'm affected by CVE-2022-1374?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors