# CVE-2022-1159: Rockwell Automation Studio 5000 Logix Designer Code Injection

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 7.7
- **CVSS:** 7.7 (v3.1, CNA) `CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H`
- **CVSS metrics:** Attack vector: Local; Attack complexity: Low; Privileges required: High; User interaction: Required; Scope: Changed (impact reaches other components); Confidentiality impact: High; Integrity impact: High; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 2.08% (percentile 82, 2026-11-26)
- **CWE:** CWE-94
- **Published:** 2022-04-01T22:17:51.000Z
- **Modified:** 2026-06-17T04:21:55.450Z

## Who should check

- Anyone running Rockwell Automation Studio 5000 Logix Designer All

## Description

Rockwell Automation Studio 5000 Logix Designer (all versions) are vulnerable when an attacker who achieves administrator access on a workstation running Studio 5000 Logix Designer could inject controller code undetectable to a user.

## Affected and fixed versions

- Rockwell Automation Studio 5000 Logix Designer: All (cvelist)

## Mitigation

- Vendor workaround: Rockwell Automation recommends users of the affected hardware and software take risk mitigation steps listed below. Users are encouraged, when possible, to combine this guidance with the general security guidelines for a comprehensive defense-in-depth strategy.
- 
- There is no direct mitigation for this vulnerability in the Logix Designer application. However, a detection method is available to determine if the user program residing in the controller is identical to what was downloaded. This user program verification can be done by the following:
- 
- On-demand using the Logix Designer application Compare Tool v9 or later
- Scheduled using FactoryTalk AssetCentre v12 or later user program verification (Available Fall 2022)
- To leverage these detection capabilities, users are directed to upgrade to:
- 
- Studio 5000 v34 software. or later
- Corresponding versions of Logix 5580, 5380, 5480, GuardLogix 5580 and Compact GuardLogix 5380 controller firmware.
- One of the following compare tools
- Logix Designer application Compare Tool v9 or later – installed with Studio 5000 Logix Designer
- FactoryTalk AssetCentre v12 or later software (Available Fall 2022)
- 
- This user program comparison must be performed on an uncompromised workstation.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2022-1159. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-1159.md
Affected: Rockwell Automation Studio 5000 Logix Designer All
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Rockwell Automation Studio 5000 Logix Designer: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2022-1159 being exploited?

There is no confirmed exploitation: CVE-2022-1159 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.08% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2022-1159?

High: CVSS 7.7 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed). A user has to take an action, such as opening a link, for the attack to work.

### Which versions are affected by CVE-2022-1159?

Rockwell Automation Studio 5000 Logix Designer All.

### Is there a fix for CVE-2022-1159?

No fixed version is listed in the sources yet. Vendor workaround: Rockwell Automation recommends users of the affected hardware and software take risk mitigation steps listed below. Users are encouraged, when possible, to combine this guidance with the general security guidelines for a comprehensive defense-in-depth strategy.  There is no direct mitigation for this vulnerability in the Logix Designer application. However, a detection method is available to determine if the user program residing in the controller is identical to what was downloaded. This user program verification can be done by the following:  On-demand using the Logix Designer application Compare Tool v9 or later Scheduled using FactoryTalk AssetCentre v12 or later user program verification (Available Fall 2022) To leverage these detection capabilities, users are directed to upgrade to:  Studio 5000 v34 software. or later Corresponding versions of Logix 5580, 5380, 5480, GuardLogix 5580 and Compact GuardLogix 5380 controller firmware. One of the following compare tools Logix Designer application Compare Tool v9 or later – installed with Studio 5000 Logix Designer FactoryTalk AssetCentre v12 or later software (Available Fall 2022)  This user program comparison must be performed on an uncompromised workstation.

### How do I check if I'm affected by CVE-2022-1159?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://www.cisa.gov/uscert/ics/advisories/icsa-22-090-07>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2022-1159>

HTML: <https://flawdb.com/CVE-2022-1159> · JSON: <https://flawdb.com/api/v1/entries/CVE-2022-1159>