CVE-2022-0902
ABB Flow Computer and Remote Controllers Path Traversal Vulnerability in Totalflow TCP protocol can lead to root access
Mitigation
- Upgrade RMC-100 (Standard) to 2105457-037 or later.
- Upgrade RMC-100-LITE to 2106229-011 or later.
- Upgrade XIO to 2106198-008 or later.
- Upgrade XFCG5 to 2105805-016 or later.
- Upgrade XRCG5 to 2105864-016 or later.
- Upgrade uFLOG5 to 2105298-024 or later.
- Upgrade UDC to 2106177-007 or later.
Who should check
- Anyone running ABB RMC-100 (Standard) >= unspecified, < 2105457-037
- Anyone running ABB RMC-100-LITE >= unspecified, < 2106229-011
- Anyone running ABB XIO >= unspecified, < 2106198-008
- Anyone running ABB XFCG5 >= unspecified, < 2105805-016
- Anyone running ABB XRCG5 >= unspecified, < 2105864-016
- Anyone running ABB uFLOG5 >= unspecified, < 2105298-024
- Anyone running ABB UDC >= unspecified, < 2106177-007
Vulnerability facts
- Affected
- ABB RMC-100 (Standard) >= unspecified, < 2105457-037; ABB RMC-100-LITE >= unspecified, < 2106229-011; ABB XIO >= unspecified, < 2106198-008; ABB XFCG5 >= unspecified, < 2105805-016; ABB XRCG5 >= unspecified, < 2105864-016; ABB uFLOG5 >= unspecified, < 2105298-024; ABB UDC >= unspecified, < 2106177-007
- Fixed in
- ABB RMC-100 (Standard) 2105457-037, ABB RMC-100-LITE 2106229-011, ABB XIO 2106198-008, ABB XFCG5 2105805-016, ABB XRCG5 2105864-016, ABB uFLOG5 2105298-024, ABB UDC 2106177-007
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.1 (v3.1, CNA)CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: High
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 1.66% chance of exploitation in 30 days (percentile 77, 2026-11-26)
- CWE
- CWE-22, CWE-77
- Modified
Description
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| ABB RMC-100 (Standard) | >= unspecified, < 2105457-037 | — | cvelist |
| ABB RMC-100-LITE | >= unspecified, < 2106229-011 | — | cvelist |
| ABB XIO | >= unspecified, < 2106198-008 | — | cvelist |
| ABB XFCG5 | >= unspecified, < 2105805-016 | — | cvelist |
| ABB XRCG5 | >= unspecified, < 2105864-016 | — | cvelist |
| ABB uFLOG5 | >= unspecified, < 2105298-024 | — | cvelist |
| ABB UDC | >= unspecified, < 2106177-007 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2022-0902. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2022-0902.md Affected: ABB RMC-100 (Standard) >= unspecified, < 2105457-037; ABB RMC-100-LITE >= unspecified, < 2106229-011; ABB XIO >= unspecified, < 2106198-008; ABB XFCG5 >= unspecified, < 2105805-016; ABB XRCG5 >= unspecified, < 2105864-016; ABB uFLOG5 >= unspecified, < 2105298-024; ABB UDC >= unspecified, < 2106177-… Fixed in: ABB RMC-100 (Standard) 2105457-037, ABB RMC-100-LITE 2106229-011, ABB XIO 2106198-008, ABB XFCG5 2105805-016, ABB XRCG5 2105864-016, ABB uFLOG5 2105298-024, ABB UDC 2106177-007 Steps: 1. Search this machine and project for ABB RMC-100 (Standard), ABB RMC-100-LITE, ABB XIO, ABB XFCG5, ABB XRCG5, ABB uFLOG5: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2022-0902 being exploited?
There is no confirmed exploitation: CVE-2022-0902 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.66% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2022-0902?
High: CVSS 8.1 (v3.1, scored by CNA). Remote, no login needed. The attack needs conditions outside the attacker's control, which makes it harder.
Which versions are affected by CVE-2022-0902?
ABB RMC-100 (Standard) >= unspecified, < 2105457-037; ABB RMC-100-LITE >= unspecified, < 2106229-011; ABB XIO >= unspecified, < 2106198-008; ABB XFCG5 >= unspecified, < 2105805-016; ABB XRCG5 >= unspecified, < 2105864-016; ABB uFLOG5 >= unspecified, < 2105298-024; ABB UDC >= unspecified, < 2106177-007.
Is there a fix for CVE-2022-0902?
Yes. Fixed in ABB RMC-100 (Standard) 2105457-037, ABB RMC-100-LITE 2106229-011, ABB XIO 2106198-008, ABB XFCG5 2105805-016, ABB XRCG5 2105864-016, ABB uFLOG5 2105298-024, ABB UDC 2106177-007. Upgrade RMC-100 (Standard) to 2105457-037 or later. Upgrade RMC-100-LITE to 2106229-011 or later. Upgrade XIO to 2106198-008 or later. Upgrade XFCG5 to 2105805-016 or later. Upgrade XRCG5 to 2105864-016 or later. Upgrade uFLOG5 to 2105298-024 or later. Upgrade UDC to 2106177-007 or later.
How do I check if I'm affected by CVE-2022-0902?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.