# CVE-2022-0878: Novel attack against the Combined Charging System (CCS) in electric vehicles to remotely cause a denial of service

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** MEDIUM 4.6
- **CVSS:** 4.6 (v3.1, CNA) `CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H`
- **CVSS metrics:** Attack vector: Physical; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: None; Integrity impact: None; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** Yes (see exploit references)
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.44% (percentile 30, 2026-11-26)
- **CWE:** CWE-306
- **Published:** 2022-04-12T12:00:23.108Z
- **Modified:** 2026-06-17T04:21:24.963Z

## Who should check

- Anyone running Combined Charging System \>= Current version, \<= 2.0
- Anyone running Combined Charging System HomePlug GreenPHY \>= Current version, \<= 1.1

## Description

Electric Vehicle (EV) commonly utilises the Combined Charging System (CCS) for DC rapid charging. To exchange important messages such as the State of Charge (SoC) with the Electric Vehicle Supply Equipment (EVSE) CCS uses a high-bandwidth IP link provided by the HomePlug Green PHY (HPGP) power-line communication (PLC) technology. The attack interrupts necessary control communication between the vehicle and charger, causing charging sessions to abort. The attack can be conducted wirelessly from a distance using electromagnetic interference, allowing individual vehicles or entire fleets to be disrupted simultaneously. In addition, the attack can be mounted with off-the-shelf radio hardware and minimal technical knowledge. With a power budget of 1 W, the attack is successful from around 47 m distance. The exploited behavior is a required part of the HomePlug Green PHY, DIN 70121 & ISO 15118 standards and all known implementations exhibit it. In addition to electric cars, Brokenwire affects electric ships, airplanes and heavy duty vehicles utilising these standards.

## Affected and fixed versions

- Combined Charging System: \>= Current version, \<= 2.0 (cvelist)
- Combined Charging System HomePlug GreenPHY: \>= Current version, \<= 1.1 (cvelist)

## Mitigation

- Vendor workaround: Using stronger shielded cables and securing the physical paramater might reducing the viability of this attack.
- Right now, the only way to prevent the attack is not to charge on a DC rapid charger.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2022-0878. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2022-0878.md
Affected: Combined Charging System >= Current version, <= 2.0; Combined Charging System HomePlug GreenPHY >= Current version, <= 1.1
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Combined Charging System, Combined Charging System HomePlug GreenPHY: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2022-0878 being exploited?

There is no confirmed exploitation: CVE-2022-0878 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 0.44% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2022-0878?

Medium: CVSS 4.6 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).

### Which versions are affected by CVE-2022-0878?

Combined Charging System \>= Current version, \<= 2.0; Combined Charging System HomePlug GreenPHY \>= Current version, \<= 1.1.

### Is there a fix for CVE-2022-0878?

No fixed version is listed in the sources yet. Vendor workaround: Using stronger shielded cables and securing the physical paramater might reducing the viability of this attack. Right now, the only way to prevent the attack is not to charge on a DC rapid charger.

### How do I check if I'm affected by CVE-2022-0878?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- exploit: <https://www.brokenwire.fail/>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2022-0878>

HTML: <https://flawdb.com/CVE-2022-0878> · JSON: <https://flawdb.com/api/v1/entries/CVE-2022-0878>
