HIGH 8.8EPSS 59%

A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens CP-8000 MASTER MODULE WITH I/O -25/+70°C All versions < V16.20
  • Anyone running Siemens CP-8000 MASTER MODULE WITH I/O -40/+70°C All versions < V16.20
  • Anyone running Siemens CP-8021 MASTER MODULE All versions < V16.20
  • Anyone running Siemens CP-8022 MASTER MODULE WITH GPRS All versions < V16.20

Vulnerability facts

Affected
Siemens CP-8000 MASTER MODULE WITH I/O -25/+70°C All versions < V16.20; Siemens CP-8000 MASTER MODULE WITH I/O -40/+70°C All versions < V16.20; Siemens CP-8021 MASTER MODULE All versions < V16.20; Siemens CP-8022 MASTER MODULE WITH GPRS All versions < V16.20
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, login needed
CVSS
8.8 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: Low
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
0.94% chance of exploitation in 30 days (percentile 59, 2026-11-26)
CWE
CWE-798
Published
Modified

Description

A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < V16.20), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < V16.20), CP-8021 MASTER MODULE (All versions < V16.20), CP-8022 MASTER MODULE WITH GPRS (All versions < V16.20). An undocumented debug port uses hard-coded default credentials. If this port is enabled by a privileged user, an attacker aware of the credentials could access an administrative debug shell on the affected device.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens CP-8000 MASTER MODULE WITH I/O -25/+70°CAll versions < V16.20—cvelist
Siemens CP-8000 MASTER MODULE WITH I/O -40/+70°CAll versions < V16.20—cvelist
Siemens CP-8021 MASTER MODULEAll versions < V16.20—cvelist
Siemens CP-8022 MASTER MODULE WITH GPRSAll versions < V16.20—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2021-45033. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2021-45033.md
Affected: Siemens CP-8000 MASTER MODULE WITH I/O -25/+70°C All versions < V16.20; Siemens CP-8000 MASTER MODULE WITH I/O -40/+70°C All versions < V16.20; Siemens CP-8021 MASTER MODULE All versions < V16.20; Siemens CP-8022 MASTER MODULE WITH GPRS All versions < V16.20
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens CP-8000 MASTER MODULE WITH I/O -25/+70°C, Siemens CP-8000 MASTER MODULE WITH I/O -40/+70°C, Siemens CP-8021 MASTER MODULE, Siemens CP-8022 MASTER MODULE WITH GPRS: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2021-45033 being exploited?

There is no confirmed exploitation: CVE-2021-45033 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.94% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2021-45033?

High: CVSS 8.8 (v3.1, scored by NVD). Remote, login needed.

Which versions are affected by CVE-2021-45033?

Siemens CP-8000 MASTER MODULE WITH I/O -25/+70°C All versions < V16.20; Siemens CP-8000 MASTER MODULE WITH I/O -40/+70°C All versions < V16.20; Siemens CP-8021 MASTER MODULE All versions < V16.20; Siemens CP-8022 MASTER MODULE WITH GPRS All versions < V16.20.

Is there a fix for CVE-2021-45033?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2021-45033?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors