CVE-2021-41841
An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that a…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running n/a (versions: see the vendor advisory)
- Anyone running Siemens RUGGEDCOM APE1808 - BIOS < V1.0.202N
- Anyone running Siemens SIMATIC Field PG M5 < V22.01.10
- Anyone running Siemens SIMATIC Field PG M6 < V26.01.13
- Anyone running Siemens SIMATIC IPC127E < V27.01.09
- Anyone running Siemens SIMATIC IPC227G < V28.01.04
- Anyone running Siemens SIMATIC IPC277G < V28.01.04
- Anyone running Siemens SIMATIC IPC277G PRO < V28.01.04
Vulnerability facts
- Affected
- n/a; Siemens RUGGEDCOM APE1808 - BIOS < V1.0.202N; Siemens SIMATIC Field PG M5 < V22.01.10; Siemens SIMATIC Field PG M6 < V26.01.13; Siemens SIMATIC IPC127E < V27.01.09; Siemens SIMATIC IPC227G < V28.01.04; Siemens SIMATIC IPC277G < V28.01.04; Siemens SIMATIC IPC277G PRO < V28.01.04; Siemens SIMATIC IPC327G < V28.01.04; Siemens SIMATIC IPC377G < V28.01.04; Siemens SIMATIC IPC427E < V21.01.17; Siemens SIMATIC IPC477E < V21.01.17; Siemens SIMATIC IPC477E PRO < V21.01.17; Siemens SIMATIC IPC627E < V25.02.12; Siemens SIMATIC IPC647E < V25.02.12; Siemens SIMATIC IPC677E < V25.02.12; Siemens SIMATIC IPC847E < V25.02.12; Siemens SIMATIC ITP1000 < V23.01.10; Siemens SIPLUS IPC427E < V21.01.17
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 8.2 (v3.1, NVD)CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Local
- Attack complexity: Low
- Privileges required: High
- User interaction: None
- Scope: Changed (impact reaches other components)
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 0.30% chance of exploitation in 30 days (percentile 15, 2026-11-26)
- CWE
- CWE-829
- Modified
Description
An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| n/a | — | — | nvd |
| Siemens RUGGEDCOM APE1808 - BIOS | < V1.0.202N | — | nvd |
| Siemens SIMATIC Field PG M5 | < V22.01.10 | — | nvd |
| Siemens SIMATIC Field PG M6 | < V26.01.13 | — | nvd |
| Siemens SIMATIC IPC127E | < V27.01.09 | — | nvd |
| Siemens SIMATIC IPC227G | < V28.01.04 | — | nvd |
| Siemens SIMATIC IPC277G | < V28.01.04 | — | nvd |
| Siemens SIMATIC IPC277G PRO | < V28.01.04 | — | nvd |
| Siemens SIMATIC IPC327G | < V28.01.04 | — | nvd |
| Siemens SIMATIC IPC377G | < V28.01.04 | — | nvd |
| Siemens SIMATIC IPC427E | < V21.01.17 | — | nvd |
| Siemens SIMATIC IPC477E | < V21.01.17 | — | nvd |
| Siemens SIMATIC IPC477E PRO | < V21.01.17 | — | nvd |
| Siemens SIMATIC IPC627E | < V25.02.12 | — | nvd |
| Siemens SIMATIC IPC647E | < V25.02.12 | — | nvd |
| Siemens SIMATIC IPC677E | < V25.02.12 | — | nvd |
| Siemens SIMATIC IPC847E | < V25.02.12 | — | nvd |
| Siemens SIMATIC ITP1000 | < V23.01.10 | — | nvd |
| Siemens SIPLUS IPC427E | < V21.01.17 | — | nvd |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2021-41841. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2021-41841.md Affected: n/a; Siemens RUGGEDCOM APE1808 - BIOS < V1.0.202N; Siemens SIMATIC Field PG M5 < V22.01.10; Siemens SIMATIC Field PG M6 < V26.01.13; Siemens SIMATIC IPC127E < V27.01.09; Siemens SIMATIC IPC227G < V28.01.04; Siemens SIMATIC IPC277G < V28.01.04; Siemens SIMATIC IPC277G PRO < V28.01.04; Siemens SIMATI… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for n/a, Siemens RUGGEDCOM APE1808 - BIOS, Siemens SIMATIC Field PG M5, Siemens SIMATIC Field PG M6, Siemens SIMATIC IPC127E, Siemens SIMATIC IPC227G: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2021-41841 being exploited?
There is no confirmed exploitation: CVE-2021-41841 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.30% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2021-41841?
High: CVSS 8.2 (v3.1, scored by NVD). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2021-41841?
n/a; Siemens RUGGEDCOM APE1808 - BIOS < V1.0.202N; Siemens SIMATIC Field PG M5 < V22.01.10; Siemens SIMATIC Field PG M6 < V26.01.13; Siemens SIMATIC IPC127E < V27.01.09; Siemens SIMATIC IPC227G < V28.01.04; Siemens SIMATIC IPC277G < V28.01.04; Siemens SIMATIC IPC277G PRO < V28.01.04; Siemens SIMATIC IPC327G < V28.01.04; Siemens SIMATIC IPC377G < V28.01.04; Siemens SIMATIC IPC427E < V21.01.17; Siemens SIMATIC IPC477E < V21.01.17; Siemens SIMATIC IPC477E PRO < V21.01.17; Siemens SIMATIC IPC627E < V25.02.12; Siemens SIMATIC IPC647E < V25.02.12; Siemens SIMATIC IPC677E < V25.02.12; Siemens SIMATIC IPC847E < V25.02.12; Siemens SIMATIC ITP1000 < V23.01.10; Siemens SIPLUS IPC427E < V21.01.17.
Is there a fix for CVE-2021-41841?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2021-41841?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.