CVE-2021-40360
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PC…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens SIMATIC PCS 7 V8.2 All versions
- Anyone running Siemens SIMATIC PCS 7 V9.0 All versions
- Anyone running Siemens SIMATIC PCS 7 V9.1 All versions < V9.1 SP1
- Anyone running Siemens SIMATIC WinCC V15 and earlier All versions < V15 SP1 Update 7
- Anyone running Siemens SIMATIC WinCC V16 All versions < V16 Update 5
- Anyone running Siemens SIMATIC WinCC V17 All versions < V17 Update 2
- Anyone running Siemens SIMATIC WinCC V7.4 All versions < V7.4 SP1 Update 19
- Anyone running Siemens SIMATIC WinCC V7.5 All versions < V7.5 SP2 Update 6
Vulnerability facts
- Affected
- Siemens SIMATIC PCS 7 V8.2 All versions; Siemens SIMATIC PCS 7 V9.0 All versions; Siemens SIMATIC PCS 7 V9.1 All versions < V9.1 SP1; Siemens SIMATIC WinCC V15 and earlier All versions < V15 SP1 Update 7; Siemens SIMATIC WinCC V16 All versions < V16 Update 5; Siemens SIMATIC WinCC V17 All versions < V17 Update 2; Siemens SIMATIC WinCC V7.4 All versions < V7.4 SP1 Update 19; Siemens SIMATIC WinCC V7.5 All versions < V7.5 SP2 Update 6
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 8.8 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: Low
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 0.68% chance of exploitation in 30 days (percentile 48, 2026-11-26)
- CWE
- CWE-200
- Modified
Description
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Siemens SIMATIC PCS 7 V8.2 | All versions | — | cvelist |
| Siemens SIMATIC PCS 7 V9.0 | All versions | — | cvelist |
| Siemens SIMATIC PCS 7 V9.1 | All versions < V9.1 SP1 | — | cvelist |
| Siemens SIMATIC WinCC V15 and earlier | All versions < V15 SP1 Update 7 | — | cvelist |
| Siemens SIMATIC WinCC V16 | All versions < V16 Update 5 | — | cvelist |
| Siemens SIMATIC WinCC V17 | All versions < V17 Update 2 | — | cvelist |
| Siemens SIMATIC WinCC V7.4 | All versions < V7.4 SP1 Update 19 | — | cvelist |
| Siemens SIMATIC WinCC V7.5 | All versions < V7.5 SP2 Update 6 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2021-40360. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2021-40360.md Affected: Siemens SIMATIC PCS 7 V8.2 All versions; Siemens SIMATIC PCS 7 V9.0 All versions; Siemens SIMATIC PCS 7 V9.1 All versions < V9.1 SP1; Siemens SIMATIC WinCC V15 and earlier All versions < V15 SP1 Update 7; Siemens SIMATIC WinCC V16 All versions < V16 Update 5; Siemens SIMATIC WinCC V17 All versions … Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens SIMATIC PCS 7 V8.2, Siemens SIMATIC PCS 7 V9.0, Siemens SIMATIC PCS 7 V9.1, Siemens SIMATIC WinCC V15 and earlier, Siemens SIMATIC WinCC V16, Siemens SIMATIC WinCC V17: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2021-40360 being exploited?
There is no confirmed exploitation: CVE-2021-40360 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.68% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2021-40360?
High: CVSS 8.8 (v3.1, scored by NVD). Remote, login needed.
Which versions are affected by CVE-2021-40360?
Siemens SIMATIC PCS 7 V8.2 All versions; Siemens SIMATIC PCS 7 V9.0 All versions; Siemens SIMATIC PCS 7 V9.1 All versions < V9.1 SP1; Siemens SIMATIC WinCC V15 and earlier All versions < V15 SP1 Update 7; Siemens SIMATIC WinCC V16 All versions < V16 Update 5; Siemens SIMATIC WinCC V17 All versions < V17 Update 2; Siemens SIMATIC WinCC V7.4 All versions < V7.4 SP1 Update 19; Siemens SIMATIC WinCC V7.5 All versions < V7.5 SP2 Update 6.
Is there a fix for CVE-2021-40360?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2021-40360?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.