Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2021-37185

HIGH 7.5EPSS 82%

A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 20…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens SIMATIC Drive Controller family All versions >= V2.9.2 < V2.9.4
  • Anyone running Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) All versions >= V21.9 < V21.9.4
  • Anyone running Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) All versions >= V4.5.0 < V4.5.2
  • Anyone running Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) All versions >= V2.9.2 < V2.9.4
  • Anyone running Siemens SIMATIC S7-1500 Software Controller All versions >= V21.9 < V21.9.4
  • Anyone running Siemens SIMATIC S7-PLCSIM Advanced All versions >= V4.0 < V4.0 SP1
  • Anyone running Siemens SIPLUS TIM 1531 IRC All versions < V2.3.6
  • Anyone running Siemens TIM 1531 IRC All versions < V2.3.6

Vulnerability facts

Affected
Siemens SIMATIC Drive Controller family All versions >= V2.9.2 < V2.9.4; Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) All versions >= V21.9 < V21.9.4; Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) All versions >= V4.5.0 < V4.5.2; Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) All versions >= V2.9.2 < V2.9.4; Siemens SIMATIC S7-1500 Software Controller All versions >= V21.9 < V21.9.4; Siemens SIMATIC S7-PLCSIM Advanced All versions >= V4.0 < V4.0 SP1; Siemens SIPLUS TIM 1531 IRC All versions < V2.3.6; Siemens TIM 1531 IRC All versions < V2.3.6
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
7.5 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:COpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: High
  • E: P
  • RL: O
  • RC: C
EPSS
2.06% chance of exploitation in 30 days (percentile 82, 2026-11-26)
CWE
CWE-672
Published
Modified

Description

A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens SIMATIC Drive Controller familyAll versions >= V2.9.2 < V2.9.4—cvelist
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)All versions >= V21.9 < V21.9.4—cvelist
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants)All versions >= V4.5.0 < V4.5.2—cvelist
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)All versions >= V2.9.2 < V2.9.4—cvelist
Siemens SIMATIC S7-1500 Software ControllerAll versions >= V21.9 < V21.9.4—cvelist
Siemens SIMATIC S7-PLCSIM AdvancedAll versions >= V4.0 < V4.0 SP1—cvelist
Siemens SIPLUS TIM 1531 IRCAll versions < V2.3.6—cvelist
Siemens TIM 1531 IRCAll versions < V2.3.6—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2021-37185. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2021-37185.md
Affected: Siemens SIMATIC Drive Controller family All versions >= V2.9.2 < V2.9.4; Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) All versions >= V21.9 < V21.9.4; Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) All versions >= V4.5.0 < V4.5.2; Siemens SIMATIC S7-15…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens SIMATIC Drive Controller family, Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants), Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), Siemens SIMATIC S7-1500 Software C…: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2021-37185 being exploited?

There is no confirmed exploitation: CVE-2021-37185 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.06% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2021-37185?

High: CVSS 7.5 (v3.1, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2021-37185?

Siemens SIMATIC Drive Controller family All versions >= V2.9.2 < V2.9.4; Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) All versions >= V21.9 < V21.9.4; Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) All versions >= V4.5.0 < V4.5.2; Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) All versions >= V2.9.2 < V2.9.4; Siemens SIMATIC S7-1500 Software Controller All versions >= V21.9 < V21.9.4; Siemens SIMATIC S7-PLCSIM Advanced All versions >= V4.0 < V4.0 SP1; Siemens SIPLUS TIM 1531 IRC All versions < V2.3.6; Siemens TIM 1531 IRC All versions < V2.3.6.

Is there a fix for CVE-2021-37185?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2021-37185?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors