CVE-2021-37172
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fa…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) V4.5.0
Vulnerability facts
- Affected
- Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) V4.5.0
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 7.5 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: High
- Availability impact: None
- EPSS
- 0.92% chance of exploitation in 30 days (percentile 59, 2026-11-26)
- CWE
- CWE-287
- Modified
Description
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) | V4.5.0 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2021-37172. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2021-37172.md Affected: Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) V4.5.0 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants): dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2021-37172 being exploited?
There is no confirmed exploitation: CVE-2021-37172 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.92% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2021-37172?
High: CVSS 7.5 (v3.1, scored by NVD). Remote, no login needed.
Which versions are affected by CVE-2021-37172?
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) V4.5.0.
Is there a fix for CVE-2021-37172?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2021-37172?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.