# CVE-2021-35526: Storage of Sensitive Information Vulnerability in Hitachi ABB Power Grids System Data Manager – SDM600 Product

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** MEDIUM 6.3
- **CVSS:** 6.3 (v3.1, CNA) `CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L`
- **CVSS metrics:** Attack vector: Local; Attack complexity: Low; Privileges required: Low; User interaction: None; Scope: Changed (impact reaches other components); Confidentiality impact: Low; Integrity impact: Low; Availability impact: Low
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.13% (percentile 1, 2026-11-26)
- **CWE:** CWE-312
- **Published:** 2021-09-08T15:10:08.403Z
- **Modified:** 2026-06-17T03:57:38.343Z

## Who should check

- Anyone running Hitachi ABB Power Grids System Data Manager – SDM600 \>= 1.2, \< FP2 HF6

## Description

Backup file without encryption vulnerability is found in Hitachi ABB Power Grids System Data Manager – SDM600 allows attacker to gain access to sensitive information. This issue affects: Hitachi ABB Power Grids System Data Manager – SDM600 1.2 versions prior to FP2 HF6 (Build Nr. 1.2.14002.257).

## Affected and fixed versions

- Hitachi ABB Power Grids System Data Manager – SDM600: \>= 1.2, \< FP2 HF6 (cvelist)

## Mitigation

- Vendor workaround: It is recommended to implement and continuously revise least privileges principles to minimize permissions and accesses to SDM600 related resources. Furthermore, recommended security practices as defined in SDM600 security deployment guideline and firewall configurations can help to protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.
- 
- Additional recommendation is to follow the hardening guidelines published by “The Center for Internet Security (CIS)” https://www.cisecurity.org/about-us/ to protect the host Operating System.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2021-35526. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2021-35526.md
Affected: Hitachi ABB Power Grids System Data Manager – SDM600 >= 1.2, < FP2 HF6
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Hitachi ABB Power Grids System Data Manager – SDM600: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2021-35526 being exploited?

There is no confirmed exploitation: CVE-2021-35526 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.13% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2021-35526?

Medium: CVSS 6.3 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).

### Which versions are affected by CVE-2021-35526?

Hitachi ABB Power Grids System Data Manager – SDM600 \>= 1.2, \< FP2 HF6.

### Is there a fix for CVE-2021-35526?

No fixed version is listed in the sources yet. Vendor workaround: It is recommended to implement and continuously revise least privileges principles to minimize permissions and accesses to SDM600 related resources. Furthermore, recommended security practices as defined in SDM600 security deployment guideline and firewall configurations can help to protect a process control network from attacks that originate from outside the network. Such practices include that process control systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that have to be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.  Additional recommendation is to follow the hardening guidelines published by “The Center for Internet Security (CIS)” https://www.cisecurity.org/about-us/ to protect the host Operating System.

### How do I check if I'm affected by CVE-2021-35526?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://search.abb.com/library/Download.aspx?utm_campaign=&utm_content=2021.08_5051_Cybersecurity%20Advisory%3A&utm_medium=email&utm_source=Eloqua&DocumentID=9AKK107992A4700&LanguageCode=en&DocumentPartId=&Action=Launch&elqTrackId=ba79ef3d8aec4a4fad6c0cbe06d33d6c&elq=1bda419954724e908db108def16646a5&elqaid=3638&elqat=1&elqCampaignId=>
- other: <https://us-cert.cisa.gov/ics/advisories/icsa-21-250-02>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2021-35526>

HTML: <https://flawdb.com/CVE-2021-35526> · JSON: <https://flawdb.com/api/v1/entries/CVE-2021-35526>