Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2021-34594

MEDIUM 6.5EPSS 66%

Beckhoff: Relative path traversal vulnerability through TwinCAT OPC UA Server

Mitigation

  • Upgrade TwinCAT OPC UA Server to 3.2.0.19423 or later.

Who should check

  • Anyone running Beckhoff Automation TwinCAT OPC UA Server >= TF6100, < 4.3.48.0; >= TS6100, < 4.3.48.0; >= TcOpcUaServer version, < 3.2.0.19423

Vulnerability facts

Affected
Beckhoff Automation TwinCAT OPC UA Server >= TF6100, < 4.3.48.0; >= TS6100, < 4.3.48.0; >= TcOpcUaServer version, < 3.2.0.19423
Fixed in
Beckhoff Automation TwinCAT OPC UA Server 4.3.48.0, Beckhoff Automation TwinCAT OPC UA Server 4.3.48.0, Beckhoff Automation TwinCAT OPC UA Server 3.2.0.19423
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, login needed
CVSS
6.5 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: High
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: High
  • Availability impact: High
EPSS
1.13% chance of exploitation in 30 days (percentile 66, 2026-11-26)
CWE
CWE-23
Published
Modified

Description

TwinCAT OPC UA Server in TF6100 and TS6100 in product versions before 4.3.48.0 or with TcOpcUaServer versions below 3.2.0.194 are prone to a relative path traversal that allow administrators to create or delete any files on the system.

Affected and fixed versions

Package / productAffectedFixedSource
Beckhoff Automation TwinCAT OPC UA Server>= TF6100, < 4.3.48.0; >= TS6100, < 4.3.48.0; >= TcOpcUaServer version, < 3.2.0.19423—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2021-34594. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2021-34594.md
Affected: Beckhoff Automation TwinCAT OPC UA Server >= TF6100, < 4.3.48.0; >= TS6100, < 4.3.48.0; >= TcOpcUaServer version, < 3.2.0.19423
Fixed in: Beckhoff Automation TwinCAT OPC UA Server 4.3.48.0, Beckhoff Automation TwinCAT OPC UA Server 4.3.48.0, Beckhoff Automation TwinCAT OPC UA Server 3.2.0.19423

Steps:
1. Search this machine and project for Beckhoff Automation TwinCAT OPC UA Server: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2021-34594 being exploited?

There is no confirmed exploitation: CVE-2021-34594 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.13% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2021-34594?

Medium: CVSS 6.5 (v3.1, scored by CNA). Remote, login needed.

Which versions are affected by CVE-2021-34594?

Beckhoff Automation TwinCAT OPC UA Server >= TF6100, < 4.3.48.0; >= TS6100, < 4.3.48.0; >= TcOpcUaServer version, < 3.2.0.19423.

Is there a fix for CVE-2021-34594?

Yes. Fixed in Beckhoff Automation TwinCAT OPC UA Server 4.3.48.0, Beckhoff Automation TwinCAT OPC UA Server 4.3.48.0, Beckhoff Automation TwinCAT OPC UA Server 3.2.0.19423. Upgrade TwinCAT OPC UA Server to 3.2.0.19423 or later.

How do I check if I'm affected by CVE-2021-34594?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors