CVE-2021-32986
Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel
Mitigation
- Upgrade CLICK PLC CPU Modules: C0-1x CPUs to 3.00 or later.
Who should check
- Anyone running Automation Direct CLICK PLC CPU Modules: C0-1x CPUs >= unspecified, < 3.00
Vulnerability facts
- Affected
- Automation Direct CLICK PLC CPU Modules: C0-1x CPUs >= unspecified, < 3.00
- Fixed in
- Automation Direct CLICK PLC CPU Modules: C0-1x CPUs 3.00
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 9.8 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 1.11% chance of exploitation in 30 days (percentile 66, 2026-11-26)
- CWE
- CWE-288
- Modified
Description
After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming connections are allowed without authorization. The PLC is only relocked by a power cycle, or when the programming software disconnects correctly.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Automation Direct CLICK PLC CPU Modules: C0-1x CPUs | >= unspecified, < 3.00 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2021-32986. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2021-32986.md Affected: Automation Direct CLICK PLC CPU Modules: C0-1x CPUs >= unspecified, < 3.00 Fixed in: Automation Direct CLICK PLC CPU Modules: C0-1x CPUs 3.00 Steps: 1. Search this machine and project for Automation Direct CLICK PLC CPU Modules: C0-1x CPUs: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2021-32986 being exploited?
There is no confirmed exploitation: CVE-2021-32986 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.11% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2021-32986?
Critical: CVSS 9.8 (v3.1, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2021-32986?
Automation Direct CLICK PLC CPU Modules: C0-1x CPUs >= unspecified, < 3.00.
Is there a fix for CVE-2021-32986?
Yes. Fixed in Automation Direct CLICK PLC CPU Modules: C0-1x CPUs 3.00. Upgrade CLICK PLC CPU Modules: C0-1x CPUs to 3.00 or later.
How do I check if I'm affected by CVE-2021-32986?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.