# CVE-2021-32025: An elevation of privilege vulnerability in the QNX Neutrino Kernel of affected versions of QNX Software Development Pla…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 8.1
- **CVSS:** 8.1 (v3.1, CNA) `CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H`
- **CVSS metrics:** Attack vector: Local; Attack complexity: High; Privileges required: None; User interaction: None; Scope: Changed (impact reaches other components); Confidentiality impact: High; Integrity impact: High; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.18% (percentile 4, 2026-11-26)
- **CWE:** CWE-368
- **Published:** 2022-03-09T20:37:56.000Z
- **Modified:** 2026-06-17T03:52:41.860Z

## Who should check

- Anyone running BlackBerry QNX Software Development Platform (SDP), QNX OS for Medical (QOSM), and QNX OS for Safety (QOS) QNX SDP 6.4.0 to 7.0; QNX Momentics all 6.3.x versions; QNX OS for Safety versions 1.0.0 to 1.0.2 safety products compliant with IEC 61508 and/or ISO 26262; QNX OS for Safety versions 2.0.0 to 2.0.1 safety products compliant with IEC 61508 and/or ISO 26262; QNX OS for Medical versions 1.0.0 to 1.1.1 safety products compliant with IEC 62304; QNX OS for Medical versions 2.0.0 safety product compliant with IEC 62304

## Description

An elevation of privilege vulnerability in the QNX Neutrino Kernel of affected versions of QNX Software Development Platform version(s) 6.4.0 to 7.0, QNX Momentics all 6.3.x versions, QNX OS for Safety versions 1.0.0 to 1.0.2, QNX OS for Safety versions 2.0.0 to 2.0.1, QNX for Medical versions 1.0.0 to 1.1.1, and QNX OS for Medical version 2.0.0 could allow an attacker to potentially access data, modify behavior, or permanently crash the system.

## Affected and fixed versions

- BlackBerry QNX Software Development Platform (SDP), QNX OS for Medical (QOSM), and QNX OS for Safety (QOS): QNX SDP 6.4.0 to 7.0; QNX Momentics all 6.3.x versions; QNX OS for Safety versions 1.0.0 to 1.0.2 safety products compliant with IEC 61508 and/or ISO 26262; QNX OS for Safety versions 2.0.0 to 2.0.1 safety products compliant with IEC 61508 and/or ISO 26262; QNX OS for Medical versions 1.0.0 to 1.1.1 safety products compliant with IEC 62304; QNX OS for Medical versions 2.0.0 safety product compliant with IEC 62304 (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2021-32025. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2021-32025.md
Affected: BlackBerry QNX Software Development Platform (SDP), QNX OS for Medical (QOSM), and QNX OS for Safety (QOS) QNX SDP 6.4.0 to 7.0; QNX Momentics all 6.3.x versions; QNX OS for Safety versions 1.0.0 to 1.0.2 safety products compliant with IEC 61508 and/or ISO 26262; QNX OS for Safety versions 2.0.0 to…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for BlackBerry QNX Software Development Platform (SDP), QNX OS for Medical (QOSM), and QNX OS for Safety (QOS): dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2021-32025 being exploited?

There is no confirmed exploitation: CVE-2021-32025 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.18% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2021-32025?

High: CVSS 8.1 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed). The attack needs conditions outside the attacker's control, which makes it harder.

### Which versions are affected by CVE-2021-32025?

BlackBerry QNX Software Development Platform (SDP), QNX OS for Medical (QOSM), and QNX OS for Safety (QOS) QNX SDP 6.4.0 to 7.0; QNX Momentics all 6.3.x versions; QNX OS for Safety versions 1.0.0 to 1.0.2 safety products compliant with IEC 61508 and/or ISO 26262; QNX OS for Safety versions 2.0.0 to 2.0.1 safety products compliant with IEC 61508 and/or ISO 26262; QNX OS for Medical versions 1.0.0 to 1.1.1 safety products compliant with IEC 62304; QNX OS for Medical versions 2.0.0 safety product compliant with IEC 62304.

### Is there a fix for CVE-2021-32025?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2021-32025?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- patch: <http://support.blackberry.com/kb/articleDetail?articleNumber=000090868>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2021-32025>

HTML: <https://flawdb.com/CVE-2021-32025> · JSON: <https://flawdb.com/api/v1/entries/CVE-2021-32025>