CVE-2021-31886

CRITICAL 9.8EPSS 88%

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All ve…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens APOGEE MBC (PPC) (BACnet) All versions
  • Anyone running Siemens APOGEE MBC (PPC) (P2 Ethernet) All versions
  • Anyone running Siemens APOGEE MEC (PPC) (BACnet) All versions
  • Anyone running Siemens APOGEE MEC (PPC) (P2 Ethernet) All versions
  • Anyone running Siemens APOGEE PXC Compact (BACnet) All versions < V3.5.4
  • Anyone running Siemens APOGEE PXC Compact (P2 Ethernet) All versions < V2.8.19
  • Anyone running Siemens APOGEE PXC Modular (BACnet) All versions < V3.5.4
  • Anyone running Siemens APOGEE PXC Modular (P2 Ethernet) All versions < V2.8.19

Vulnerability facts

Affected
Siemens APOGEE MBC (PPC) (BACnet) All versions; Siemens APOGEE MBC (PPC) (P2 Ethernet) All versions; Siemens APOGEE MEC (PPC) (BACnet) All versions; Siemens APOGEE MEC (PPC) (P2 Ethernet) All versions; Siemens APOGEE PXC Compact (BACnet) All versions < V3.5.4; Siemens APOGEE PXC Compact (P2 Ethernet) All versions < V2.8.19; Siemens APOGEE PXC Modular (BACnet) All versions < V3.5.4; Siemens APOGEE PXC Modular (P2 Ethernet) All versions < V2.8.19; Siemens Desigo PXC00-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC00-U All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC001-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC100-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC12-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC128-U All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC200-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC22-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC22.1-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC36.1-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC50-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC64-U All versions >= V2.3 and < V6.30.016; Siemens Desigo PXM20-E All versions >= V2.3 and < V6.30.016; Siemens Nucleus NET All versions; Siemens Nucleus ReadyStart V3 All versions < V2017.02.4; Siemens Nucleus Source Code All versions; Siemens TALON TC Compact (BACnet) All versions < V3.5.4; Siemens TALON TC Modular (BACnet) All versions < V3.5.4
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
9.8 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
3.08% chance of exploitation in 30 days (percentile 88, 2026-11-26)
CWE
CWE-170
Published
Modified

Description

A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.19), APOGEE PXC Modular (BACnet) (All versions < V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.19), Desigo PXC00-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC00-U (All versions >= V2.3 and < V6.30.016), Desigo PXC001-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC100-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC12-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC128-U (All versions >= V2.3 and < V6.30.016), Desigo PXC200-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC22.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC36.1-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC50-E.D (All versions >= V2.3 and < V6.30.016), Desigo PXC64-U (All versions >= V2.3 and < V6.30.016), Desigo PXM20-E (All versions >= V2.3 and < V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions < V3.5.4), TALON TC Modular (BACnet) (All versions < V3.5.4). FTP server does not properly validate the length of the “USER” command, leading to stack-based buffer overflows. This may result in Denial-of-Service conditions and Remote Code Execution. (FSMD-2021-0010)

Affected and fixed versions

Package / productAffectedFixedSource
Siemens APOGEE MBC (PPC) (BACnet)All versions—cvelist
Siemens APOGEE MBC (PPC) (P2 Ethernet)All versions—cvelist
Siemens APOGEE MEC (PPC) (BACnet)All versions—cvelist
Siemens APOGEE MEC (PPC) (P2 Ethernet)All versions—cvelist
Siemens APOGEE PXC Compact (BACnet)All versions < V3.5.4—cvelist
Siemens APOGEE PXC Compact (P2 Ethernet)All versions < V2.8.19—cvelist
Siemens APOGEE PXC Modular (BACnet)All versions < V3.5.4—cvelist
Siemens APOGEE PXC Modular (P2 Ethernet)All versions < V2.8.19—cvelist
Siemens Desigo PXC00-E.DAll versions >= V2.3 and < V6.30.016—cvelist
Siemens Desigo PXC00-UAll versions >= V2.3 and < V6.30.016—cvelist
Siemens Desigo PXC001-E.DAll versions >= V2.3 and < V6.30.016—cvelist
Siemens Desigo PXC100-E.DAll versions >= V2.3 and < V6.30.016—cvelist
Siemens Desigo PXC12-E.DAll versions >= V2.3 and < V6.30.016—cvelist
Siemens Desigo PXC128-UAll versions >= V2.3 and < V6.30.016—cvelist
Siemens Desigo PXC200-E.DAll versions >= V2.3 and < V6.30.016—cvelist
Siemens Desigo PXC22-E.DAll versions >= V2.3 and < V6.30.016—cvelist
Siemens Desigo PXC22.1-E.DAll versions >= V2.3 and < V6.30.016—cvelist
Siemens Desigo PXC36.1-E.DAll versions >= V2.3 and < V6.30.016—cvelist
Siemens Desigo PXC50-E.DAll versions >= V2.3 and < V6.30.016—cvelist
Siemens Desigo PXC64-UAll versions >= V2.3 and < V6.30.016—cvelist
Siemens Desigo PXM20-EAll versions >= V2.3 and < V6.30.016—cvelist
Siemens Nucleus NETAll versions—cvelist
Siemens Nucleus ReadyStart V3All versions < V2017.02.4—cvelist
Siemens Nucleus Source CodeAll versions—cvelist
Siemens TALON TC Compact (BACnet)All versions < V3.5.4—cvelist
Siemens TALON TC Modular (BACnet)All versions < V3.5.4—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2021-31886. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2021-31886.md
Affected: Siemens APOGEE MBC (PPC) (BACnet) All versions; Siemens APOGEE MBC (PPC) (P2 Ethernet) All versions; Siemens APOGEE MEC (PPC) (BACnet) All versions; Siemens APOGEE MEC (PPC) (P2 Ethernet) All versions; Siemens APOGEE PXC Compact (BACnet) All versions < V3.5.4; Siemens APOGEE PXC Compact (P2 Etherne…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens APOGEE MBC (PPC) (BACnet), Siemens APOGEE MBC (PPC) (P2 Ethernet), Siemens APOGEE MEC (PPC) (BACnet), Siemens APOGEE MEC (PPC) (P2 Ethernet), Siemens APOGEE PXC Compact (BACnet), Siemens APOGEE PXC Compact (P2 Ethernet): dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2021-31886 being exploited?

There is no confirmed exploitation: CVE-2021-31886 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 3.08% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2021-31886?

Critical: CVSS 9.8 (v3.1, scored by NVD). Remote, no login needed.

Which versions are affected by CVE-2021-31886?

Siemens APOGEE MBC (PPC) (BACnet) All versions; Siemens APOGEE MBC (PPC) (P2 Ethernet) All versions; Siemens APOGEE MEC (PPC) (BACnet) All versions; Siemens APOGEE MEC (PPC) (P2 Ethernet) All versions; Siemens APOGEE PXC Compact (BACnet) All versions < V3.5.4; Siemens APOGEE PXC Compact (P2 Ethernet) All versions < V2.8.19; Siemens APOGEE PXC Modular (BACnet) All versions < V3.5.4; Siemens APOGEE PXC Modular (P2 Ethernet) All versions < V2.8.19; Siemens Desigo PXC00-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC00-U All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC001-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC100-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC12-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC128-U All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC200-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC22-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC22.1-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC36.1-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC50-E.D All versions >= V2.3 and < V6.30.016; Siemens Desigo PXC64-U All versions >= V2.3 and < V6.30.016; Siemens Desigo PXM20-E All versions >= V2.3 and < V6.30.016; Siemens Nucleus NET All versions; Siemens Nucleus ReadyStart V3 All versions < V2017.02.4; Siemens Nucleus Source Code All versions; Siemens TALON TC Compact (BACnet) All versions < V3.5.4; Siemens TALON TC Modular (BACnet) All versions < V3.5.4.

Is there a fix for CVE-2021-31886?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2021-31886?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors