Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2021-31346

HIGH 8.2EPSS 81%

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens Capital Embedded AR Classic 431-422 < *
  • Anyone running Siemens Capital Embedded AR Classic R20-11 < V2303
  • Anyone running Siemens PLUSCONTROL 1st Gen All versions
  • Anyone running Siemens SIMOTICS CONNECT 400 All versions < V0.5.0.0
  • Anyone running Siemens SIMOTICS CONNECT 400 All versions < V1.0.0.0

Vulnerability facts

Affected
Siemens Capital Embedded AR Classic 431-422 < *; Siemens Capital Embedded AR Classic R20-11 < V2303; Siemens PLUSCONTROL 1st Gen All versions; Siemens SIMOTICS CONNECT 400 All versions < V0.5.0.0; Siemens SIMOTICS CONNECT 400 All versions < V1.0.0.0
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
8.2 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: Low
  • Integrity impact: None
  • Availability impact: High
EPSS
1.97% chance of exploitation in 30 days (percentile 81, 2026-11-26)
CWE
CWE-1284
Published
Modified

Description

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). The total length of an ICMP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on the network buffer organization in memory. (FSMD-2021-0007)

Affected and fixed versions

Package / productAffectedFixedSource
Siemens Capital Embedded AR Classic 431-422< *—cvelist
Siemens Capital Embedded AR Classic R20-11< V2303—cvelist
Siemens PLUSCONTROL 1st GenAll versions—cvelist
Siemens SIMOTICS CONNECT 400All versions < V0.5.0.0—cvelist
Siemens SIMOTICS CONNECT 400All versions < V1.0.0.0—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2021-31346. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2021-31346.md
Affected: Siemens Capital Embedded AR Classic 431-422 < *; Siemens Capital Embedded AR Classic R20-11 < V2303; Siemens PLUSCONTROL 1st Gen All versions; Siemens SIMOTICS CONNECT 400 All versions < V0.5.0.0; Siemens SIMOTICS CONNECT 400 All versions < V1.0.0.0
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens Capital Embedded AR Classic 431-422, Siemens Capital Embedded AR Classic R20-11, Siemens PLUSCONTROL 1st Gen, Siemens SIMOTICS CONNECT 400: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2021-31346 being exploited?

There is no confirmed exploitation: CVE-2021-31346 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.97% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2021-31346?

High: CVSS 8.2 (v3.1, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2021-31346?

Siemens Capital Embedded AR Classic 431-422 < *; Siemens Capital Embedded AR Classic R20-11 < V2303; Siemens PLUSCONTROL 1st Gen All versions; Siemens SIMOTICS CONNECT 400 All versions < V0.5.0.0; Siemens SIMOTICS CONNECT 400 All versions < V1.0.0.0.

Is there a fix for CVE-2021-31346?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2021-31346?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors