CVE-2021-31345
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens Capital Embedded AR Classic 431-422 < *
- Anyone running Siemens Capital Embedded AR Classic R20-11 < V2303
- Anyone running Siemens PLUSCONTROL 1st Gen All versions
Vulnerability facts
- Affected
- Siemens Capital Embedded AR Classic 431-422 < *; Siemens Capital Embedded AR Classic R20-11 < V2303; Siemens PLUSCONTROL 1st Gen All versions
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 7.5 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: None
- Availability impact: None
- EPSS
- 1.63% chance of exploitation in 30 days (percentile 77, 2026-11-26)
- CWE
- CWE-1284
- Modified
Description
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2021-31345. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2021-31345.md Affected: Siemens Capital Embedded AR Classic 431-422 < *; Siemens Capital Embedded AR Classic R20-11 < V2303; Siemens PLUSCONTROL 1st Gen All versions Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens Capital Embedded AR Classic 431-422, Siemens Capital Embedded AR Classic R20-11, Siemens PLUSCONTROL 1st Gen: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
Other
- https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf
- https://cert-portal.siemens.com/productcert/pdf/ssa-845392.pdf
- https://cert-portal.siemens.com/productcert/html/ssa-114589.html
- https://cert-portal.siemens.com/productcert/html/ssa-044112.html
- https://cert-portal.siemens.com/productcert/html/ssa-620288.html
- https://cert-portal.siemens.com/productcert/html/ssa-845392.html
FAQ
Is CVE-2021-31345 being exploited?
There is no confirmed exploitation: CVE-2021-31345 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.63% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2021-31345?
High: CVSS 7.5 (v3.1, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2021-31345?
Siemens Capital Embedded AR Classic 431-422 < *; Siemens Capital Embedded AR Classic R20-11 < V2303; Siemens PLUSCONTROL 1st Gen All versions.
Is there a fix for CVE-2021-31345?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2021-31345?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.