# CVE-2021-31337: The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authenticat…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** CRITICAL 9.8
- **CVSS:** 9.8 (v3.1, NVD) `CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: High; Integrity impact: High; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 1.67% (percentile 77, 2026-11-26)
- **CWE:** CWE-306
- **Published:** 2021-06-28T12:24:58.000Z
- **Modified:** 2026-06-17T03:51:34.163Z

## Who should check

- Anyone running SINAMICS Medium Voltage Products SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions

## Description

The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions).

## Affected and fixed versions

- SINAMICS Medium Voltage Products: SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2021-31337. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2021-31337.md
Affected: SINAMICS Medium Voltage Products SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for SINAMICS Medium Voltage Products: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2021-31337 being exploited?

There is no confirmed exploitation: CVE-2021-31337 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.67% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2021-31337?

Critical: CVSS 9.8 (v3.1, scored by NVD). Remote, no login needed.

### Which versions are affected by CVE-2021-31337?

SINAMICS Medium Voltage Products SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions.

### Is there a fix for CVE-2021-31337?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2021-31337?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2021-31337>

HTML: <https://flawdb.com/CVE-2021-31337> · JSON: <https://flawdb.com/api/v1/entries/CVE-2021-31337>