# CVE-2021-27663: CEM Systems AC2000

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 8.2
- **CVSS:** 8.2 (v3.1, CNA) `CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: High; Integrity impact: Low; Availability impact: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 1.67% (percentile 77, 2026-11-26)
- **CWE:** CWE-285
- **Published:** 2021-08-30T16:37:41.273Z
- **Modified:** 2026-06-17T03:45:19.170Z

## Who should check

- Anyone running Johnson Controls CEM Systems AC2000 \>= 10.1, \<= 10.5

## Description

A vulnerability in versions 10.1 through 10.5 of Johnson Controls CEM Systems AC2000 allows a remote attacker to access to the system without adequate authorization. This issue affects: Johnson Controls CEM Systems AC2000 10.1; 10.2; 10.3; 10.4; 10.5.

## Affected and fixed versions

- Johnson Controls CEM Systems AC2000: \>= 10.1, \<= 10.5 (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2021-27663. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2021-27663.md
Affected: Johnson Controls CEM Systems AC2000 >= 10.1, <= 10.5
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Johnson Controls CEM Systems AC2000: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2021-27663 being exploited?

There is no confirmed exploitation: CVE-2021-27663 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.67% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2021-27663?

High: CVSS 8.2 (v3.1, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2021-27663?

Johnson Controls CEM Systems AC2000 \>= 10.1, \<= 10.5.

### Is there a fix for CVE-2021-27663?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2021-27663?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://www.johnsoncontrols.com/cyber-solutions/security-advisories>
- other: <https://us-cert.gov/ics/advisories/ICSA-21-238-01>