CVE-2021-27475
Rockwell Automation Connected Components Workbench Deserialization of Untrusted Data
Mitigation
- Vendor workaround: Users who are unable to update are directed towards risk mitigation strategies provided below, and are encouraged, when possible, to combine these with Rockwell Automation’s general security guidelines to employ multiple strategies simultaneously.
- If upgrade is not possible, Rockwell Automation recommends deploying the following mitigations:
- Run Connected Components Workbench as a User, not as an Administrator, to minimize the impact of malicious code on the infected system.
- Do not open untrusted .ccwarc, files with Connected Components Workbench. Employ training and awareness programs to educate users on the warning signs of a phishing or social engineering attack.
- Use of Microsoft AppLocker or other similar allow list applications can help mitigate risk. Information on using AppLocker with Rockwell Automation products is available at KnowledgeBase Article QA17329 (login required).
- Ensure the least-privilege user principle is followed, and user/service account access to shared resources (such as a database) is only granted with a minimum number of rights as needed.
- For more information, please see the industrial security advisory from Rockwell Automation.
Who should check
- Anyone running Rockwell Automation Connected Components Workbench >= unspecified, <= v12.00.00
Vulnerability facts
- Affected
- Rockwell Automation Connected Components Workbench >= unspecified, <= v12.00.00
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 8.6 (v3.1, CNA)CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Local
- Attack complexity: Low
- Privileges required: None
- User interaction: Required
- Scope: Changed (impact reaches other components)
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 2.99% chance of exploitation in 30 days (percentile 88, 2026-11-26)
- CWE
- CWE-502
- Modified
Description
Rockwell Automation Connected Components Workbench v12.00.00 and prior does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in remote code execution. This vulnerability requires user interaction to be successfully exploited.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Rockwell Automation Connected Components Workbench | >= unspecified, <= v12.00.00 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2021-27475. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2021-27475.md Affected: Rockwell Automation Connected Components Workbench >= unspecified, <= v12.00.00 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Rockwell Automation Connected Components Workbench: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2021-27475 being exploited?
There is no confirmed exploitation: CVE-2021-27475 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.99% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2021-27475?
High: CVSS 8.6 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed). A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2021-27475?
Rockwell Automation Connected Components Workbench >= unspecified, <= v12.00.00.
Is there a fix for CVE-2021-27475?
No fixed version is listed in the sources yet. Vendor workaround: Users who are unable to update are directed towards risk mitigation strategies provided below, and are encouraged, when possible, to combine these with Rockwell Automation’s general security guidelines to employ multiple strategies simultaneously. If upgrade is not possible, Rockwell Automation recommends deploying the following mitigations: Run Connected Components Workbench as a User, not as an Administrator, to minimize the impact of malicious code on the infected system. Do not open untrusted .ccwarc, files with Connected Components Workbench. Employ training and awareness programs to educate users on the warning signs of a phishing or social engineering attack. Use of Microsoft AppLocker or other similar allow list applications can help mitigate risk. Information on using AppLocker with Rockwell Automation products is available at KnowledgeBase Article QA17329 (login required). Ensure the least-privilege user principle is followed, and user/service account access to shared resources (such as a database) is only granted with a minimum number of rights as needed. For more information, please see the industrial security advisory from Rockwell Automation.
How do I check if I'm affected by CVE-2021-27475?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.