CVE-2021-25667
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens RUGGEDCOM RM1224 All versions >= V4.3 and < V6.4
- Anyone running Siemens SCALANCE M-800 All versions >= V4.3 and < V6.4
- Anyone running Siemens SCALANCE S615 All versions >= V4.3 and < V6.4
- Anyone running Siemens SCALANCE SC-600 Family All versions >= V2.0 and < V2.1.3
- Anyone running Siemens SCALANCE XB-200 All versions < V4.1
- Anyone running Siemens SCALANCE XC-200 All versions < V4.1
- Anyone running Siemens SCALANCE XF-200BA All versions < V4.1
- Anyone running Siemens SCALANCE XM400 All versions < V6.2
Vulnerability facts
- Affected
- Siemens RUGGEDCOM RM1224 All versions >= V4.3 and < V6.4; Siemens SCALANCE M-800 All versions >= V4.3 and < V6.4; Siemens SCALANCE S615 All versions >= V4.3 and < V6.4; Siemens SCALANCE SC-600 Family All versions >= V2.0 and < V2.1.3; Siemens SCALANCE XB-200 All versions < V4.1; Siemens SCALANCE XC-200 All versions < V4.1; Siemens SCALANCE XF-200BA All versions < V4.1; Siemens SCALANCE XM400 All versions < V6.2; Siemens SCALANCE XP-200 All versions < V4.1; Siemens SCALANCE XR-300WG All versions < V4.1; Siemens SCALANCE XR500 All versions < V6.2
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 6.5 (v3.1, CNA)CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Adjacent network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- EPSS
- 0.95% chance of exploitation in 30 days (percentile 60, 2026-11-26)
- CWE
- CWE-121
- Modified
Description
A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Siemens RUGGEDCOM RM1224 | All versions >= V4.3 and < V6.4 | — | cvelist |
| Siemens SCALANCE M-800 | All versions >= V4.3 and < V6.4 | — | cvelist |
| Siemens SCALANCE S615 | All versions >= V4.3 and < V6.4 | — | cvelist |
| Siemens SCALANCE SC-600 Family | All versions >= V2.0 and < V2.1.3 | — | cvelist |
| Siemens SCALANCE XB-200 | All versions < V4.1 | — | cvelist |
| Siemens SCALANCE XC-200 | All versions < V4.1 | — | cvelist |
| Siemens SCALANCE XF-200BA | All versions < V4.1 | — | cvelist |
| Siemens SCALANCE XM400 | All versions < V6.2 | — | cvelist |
| Siemens SCALANCE XP-200 | All versions < V4.1 | — | cvelist |
| Siemens SCALANCE XR-300WG | All versions < V4.1 | — | cvelist |
| Siemens SCALANCE XR500 | All versions < V6.2 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2021-25667. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2021-25667.md Affected: Siemens RUGGEDCOM RM1224 All versions >= V4.3 and < V6.4; Siemens SCALANCE M-800 All versions >= V4.3 and < V6.4; Siemens SCALANCE S615 All versions >= V4.3 and < V6.4; Siemens SCALANCE SC-600 Family All versions >= V2.0 and < V2.1.3; Siemens SCALANCE XB-200 All versions < V4.1; Siemens SCALANCE XC… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens RUGGEDCOM RM1224, Siemens SCALANCE M-800, Siemens SCALANCE S615, Siemens SCALANCE SC-600 Family, Siemens SCALANCE XB-200, Siemens SCALANCE XC-200: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2021-25667 being exploited?
There is no confirmed exploitation: CVE-2021-25667 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.95% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2021-25667?
Medium: CVSS 6.5 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2021-25667?
Siemens RUGGEDCOM RM1224 All versions >= V4.3 and < V6.4; Siemens SCALANCE M-800 All versions >= V4.3 and < V6.4; Siemens SCALANCE S615 All versions >= V4.3 and < V6.4; Siemens SCALANCE SC-600 Family All versions >= V2.0 and < V2.1.3; Siemens SCALANCE XB-200 All versions < V4.1; Siemens SCALANCE XC-200 All versions < V4.1; Siemens SCALANCE XF-200BA All versions < V4.1; Siemens SCALANCE XM400 All versions < V6.2; Siemens SCALANCE XP-200 All versions < V4.1; Siemens SCALANCE XR-300WG All versions < V4.1; Siemens SCALANCE XR500 All versions < V6.2.
Is there a fix for CVE-2021-25667?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2021-25667?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.