CVE-2021-23842
Use of Hard-coded Cryptographic Key
Mitigation
- Upgrade AMS to 4.0 or later.
- Upgrade BIS to 4.9.1 or later.
Who should check
- Anyone running Bosch AMS >= unspecified, < 4.0
- Anyone running Bosch APE >= unspecified, <= 3.8.x
- Anyone running Bosch BIS >= unspecified, < 4.9.1
- Anyone running Bosch AMC2 all
Vulnerability facts
- Affected
- Bosch AMS >= unspecified, < 4.0; Bosch APE >= unspecified, <= 3.8.x; Bosch BIS >= unspecified, < 4.9.1; Bosch AMC2 all
- Fixed in
- Bosch AMS 4.0, Bosch BIS 4.9.1
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 5.7 (v3.1, CNA)CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Adjacent network
- Attack complexity: Low
- Privileges required: None
- User interaction: Required
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: None
- Availability impact: None
- EPSS
- 0.15% chance of exploitation in 30 days (percentile 2, 2026-11-26)
- CWE
- CWE-321
- Modified
Description
Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\'s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2021-23842. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2021-23842.md Affected: Bosch AMS >= unspecified, < 4.0; Bosch APE >= unspecified, <= 3.8.x; Bosch BIS >= unspecified, < 4.9.1; Bosch AMC2 all Fixed in: Bosch AMS 4.0, Bosch BIS 4.9.1 Steps: 1. Search this machine and project for Bosch AMS, Bosch APE, Bosch BIS, Bosch AMC2: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2021-23842 being exploited?
There is no confirmed exploitation: CVE-2021-23842 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.15% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2021-23842?
Medium: CVSS 5.7 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed). A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2021-23842?
Bosch AMS >= unspecified, < 4.0; Bosch APE >= unspecified, <= 3.8.x; Bosch BIS >= unspecified, < 4.9.1; Bosch AMC2 all.
Is there a fix for CVE-2021-23842?
Yes. Fixed in Bosch AMS 4.0, Bosch BIS 4.9.1. Upgrade AMS to 4.0 or later. Upgrade BIS to 4.9.1 or later.
How do I check if I'm affected by CVE-2021-23842?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.