CVE-2021-22701
A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions) EcoStruxure™ Operator Terminal Expert 3.1 Service Pack 1A and prior running on Harmony HMIs HMIST6 Series, HMIG3U in HMIGTU Series, HMISTO Series and Pro-face BLUE 3.1 Service Pack 1A and prior running on Pro-face HMIs: ST6000 Series, SP-5B41 in SP5000 Series, GP4100 Series
Vulnerability facts
- Affected
- PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions) EcoStruxure™ Operator Terminal Expert 3.1 Service Pack 1A and prior running on Harmony HMIs HMIST6 Series, HMIG3U in HMIGTU Series, HMISTO Series and Pro-face BLUE 3.1 Service Pack 1A and prior running on Pro-face HMIs: ST6000 Series, SP-5B41 in SP5000 Series, GP4100 Series
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 6.1 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: High
- User interaction: Required
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: High
- Availability impact: High
- EPSS
- 0.34% chance of exploitation in 30 days (percentile 20, 2026-11-26)
- CWE
- CWE-352
- Modified
Description
A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions) | EcoStruxure™ Operator Terminal Expert 3.1 Service Pack 1A and prior running on Harmony HMIs HMIST6 Series, HMIG3U in HMIGTU Series, HMISTO Series and Pro-face BLUE 3.1 Service Pack 1A and prior running on Pro-face HMIs: ST6000 Series, SP-5B41 in SP5000 Series, GP4100 Series | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2021-22701. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2021-22701.md Affected: PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions) EcoStruxure™ Operator Terminal Expert 3.1 Service Pack 1A and prior running on Harmony HMIs HMIST6 Series, HMIG3U in HMIGTU Series, HMISTO Series and Pro-face BLUE 3.1 S… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions): dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2021-22701 being exploited?
There is no confirmed exploitation: CVE-2021-22701 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.34% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2021-22701?
Medium: CVSS 6.1 (v3.1, scored by CNA). Remote, login needed. A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2021-22701?
PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions) EcoStruxure™ Operator Terminal Expert 3.1 Service Pack 1A and prior running on Harmony HMIs HMIST6 Series, HMIG3U in HMIGTU Series, HMISTO Series and Pro-face BLUE 3.1 Service Pack 1A and prior running on Pro-face HMIs: ST6000 Series, SP-5B41 in SP5000 Series, GP4100 Series.