CVE-2021-1563
Cisco Video Surveillance 7000 Series IP Cameras Cisco Discovery and Link Layer Discovery Protocol Memory Leak Vulnerabilities
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Cisco Video Surveillance 7000 Series IP Cameras (versions: see the vendor advisory)
Vulnerability facts
- Affected
- Cisco Video Surveillance 7000 Series IP Cameras
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 6.5 (v3.1, CNA)CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Adjacent network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- EPSS
- 0.38% chance of exploitation in 30 days (percentile 24, 2026-11-26)
- CWE
- CWE-400
- Modified
Description
Multiple vulnerabilities in the implementation of the Cisco Discovery Protocol and Link Layer Discovery Protocol (LLDP) for Cisco Video Surveillance 7000 Series IP Cameras could allow an unauthenticated, adjacent attacker to cause a memory leak, which could lead to a denial of service (DoS) condition on an affected device. These vulnerabilities are due to incorrect processing of certain Cisco Discovery Protocol and LLDP packets at ingress time. An attacker could exploit these vulnerabilities by sending crafted Cisco Discovery Protocol or LLDP packets to an affected device. A successful exploit could allow the attacker to cause the affected device to continuously consume memory, which could cause the device to crash and reload, resulting in a DoS condition. Note: Cisco Discovery Protocol and LLDP are Layer 2 protocols. To exploit these vulnerabilities, an attacker must be in the same broadcast domain as the affected device (Layer 2 adjacent).
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Cisco Video Surveillance 7000 Series IP Cameras | — | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2021-1563. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2021-1563.md Affected: Cisco Video Surveillance 7000 Series IP Cameras Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Cisco Video Surveillance 7000 Series IP Cameras: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2021-1563 being exploited?
There is no confirmed exploitation: CVE-2021-1563 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.38% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2021-1563?
Medium: CVSS 6.5 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).
Which versions are affected by CVE-2021-1563?
Cisco Video Surveillance 7000 Series IP Cameras.
Is there a fix for CVE-2021-1563?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2021-1563?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.