# CVE-2021-0270: Junos OS: PTX Series, QFX10K Series: A PTX/QFX FPC may restart unexpectedly with the "inline-Jflow" feature enabled on a large-scale deployment

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 7.5
- **CVSS:** 7.5 (v3.1, CNA) `CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: None; Integrity impact: None; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 0.75% (percentile 51, 2026-11-26)
- **CWE:** CWE-362, CWE-416
- **Published:** 2021-04-22T19:37:26.359Z
- **Modified:** 2026-06-17T03:29:40.087Z

## Who should check

- Anyone running Juniper Networks Junos OS \>= 18.1R2, \< 18.1\*

## Description

On PTX Series and QFX10k Series devices with the "inline-jflow" feature enabled, a use after free weakness in the Packet Forwarding Engine (PFE) microkernel architecture of Juniper Networks Junos OS may allow an attacker to cause a Denial of Service (DoS) condition whereby one or more Flexible PIC Concentrators (FPCs) may restart. As this is a race condition situation this issue become more likely to be hit when network instability occurs, such as but not limited to BGP/IGP reconvergences, and/or further likely to occur when more active "traffic flows" are occurring through the device. When this issue occurs, it will cause one or more FPCs to restart unexpectedly. During FPC restarts core files will be generated. While the core file is generated traffic will be disrupted. Sustained receipt of large traffic flows and reconvergence-like situations may sustain the Denial of Service (DoS) situation. This issue affects: Juniper Networks Junos OS: 18.1 version 18.1R2 and later versions prior to 18.1R3-S10 on PTX Series, QFX10K Series.

## Affected and fixed versions

- Juniper Networks Junos OS: \>= 18.1R2, \< 18.1\* (cvelist)

## Mitigation

- Upgrade Junos OS to 18.1\* or later.
- Vendor workaround: If you are susceptible to this issue and unable to upgrade to software with the fix, you can deploy a workaround by disabling the “inline-flow” feature.
- 
- To check for use and to disable the “inline-jflow” service on a device, see https://www.juniper.net/documentation/en\_US/junos/topics/task/configuration/inline-flow-monitoring-ptx.html for additional details.
- 
- Removing “inline-jflow” takes effect immediately and there is no need to restart the FPCs or the router. Once the feature is removed, the router no longer provides traffic data to the flow collector.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2021-0270. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2021-0270.md
Affected: Juniper Networks Junos OS >= 18.1R2, < 18.1*
Fixed in: Juniper Networks Junos OS 18.1*

Steps:
1. Search this machine and project for Juniper Networks Junos OS: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2021-0270 being exploited?

There is no confirmed exploitation: CVE-2021-0270 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.75% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2021-0270?

High: CVSS 7.5 (v3.1, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2021-0270?

Juniper Networks Junos OS \>= 18.1R2, \< 18.1\*.

### Is there a fix for CVE-2021-0270?

Yes. Fixed in Juniper Networks Junos OS 18.1\*. Upgrade Junos OS to 18.1\* or later. Vendor workaround: If you are susceptible to this issue and unable to upgrade to software with the fix, you can deploy a workaround by disabling the “inline-flow” feature.  To check for use and to disable the “inline-jflow” service on a device, see https://www.juniper.net/documentation/en\_US/junos/topics/task/configuration/inline-flow-monitoring-ptx.html for additional details.  Removing “inline-jflow” takes effect immediately and there is no need to restart the FPCs or the router. Once the feature is removed, the router no longer provides traffic data to the flow collector.

### How do I check if I'm affected by CVE-2021-0270?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://kb.juniper.net/JSA11161>
- vendor: <https://www.juniper.net/documentation/en_US/junos/topics/task/configuration/inline-flow-monitoring-ptx.html>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2021-0270>

HTML: <https://flawdb.com/CVE-2021-0270> · JSON: <https://flawdb.com/api/v1/entries/CVE-2021-0270>