Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2020-7581

MEDIUM 6.7EPSS 24%

A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens Opcenter Execution Discrete All versions < V3.2
  • Anyone running Siemens Opcenter Execution Foundation All versions < V3.2
  • Anyone running Siemens Opcenter Execution Process All versions < V3.2
  • Anyone running Siemens Opcenter Intelligence All versions < V3.3
  • Anyone running Siemens Opcenter Quality All versions < V11.3
  • Anyone running Siemens Opcenter RD&L V8.0
  • Anyone running Siemens SIMATIC Notifier Server for Windows All versions
  • Anyone running Siemens SIMATIC PCS neo All versions < V3.0 SP1

Vulnerability facts

Affected
Siemens Opcenter Execution Discrete All versions < V3.2; Siemens Opcenter Execution Foundation All versions < V3.2; Siemens Opcenter Execution Process All versions < V3.2; Siemens Opcenter Intelligence All versions < V3.3; Siemens Opcenter Quality All versions < V11.3; Siemens Opcenter RD&L V8.0; Siemens SIMATIC Notifier Server for Windows All versions; Siemens SIMATIC PCS neo All versions < V3.0 SP1; Siemens SIMATIC STEP 7 (TIA Portal) V15 All versions < V15.1 Update 5; Siemens SIMATIC STEP 7 (TIA Portal) V16 All versions < V16 Update 2; Siemens SIMOCODE ES V15.1 All versions < V15.1 Update 4; Siemens SIMOCODE ES V16 All versions < V16 Update 1; Siemens Soft Starter ES V15.1 All versions < V15.1 Update 3; Siemens Soft Starter ES V16 All versions < V16 Update 1
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
6.7 (v3.1, NVD)CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Local
  • Attack complexity: Low
  • Privileges required: High
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
0.38% chance of exploitation in 30 days (percentile 24, 2026-11-26)
CWE
CWE-428
Published
Modified

Description

A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMOCODE ES V15.1 (All versions < V15.1 Update 4), SIMOCODE ES V16 (All versions < V16 Update 1), Soft Starter ES V15.1 (All versions < V15.1 Update 3), Soft Starter ES V16 (All versions < V16 Update 1). A component within the affected application calls a helper binary with SYSTEM privileges during startup while the call path is not quoted. This could allow a local attacker with administrative privileges to execute code with SYSTEM level privileges.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens Opcenter Execution DiscreteAll versions < V3.2—cvelist
Siemens Opcenter Execution FoundationAll versions < V3.2—cvelist
Siemens Opcenter Execution ProcessAll versions < V3.2—cvelist
Siemens Opcenter IntelligenceAll versions < V3.3—cvelist
Siemens Opcenter QualityAll versions < V11.3—cvelist
Siemens Opcenter RD&LV8.0—cvelist
Siemens SIMATIC Notifier Server for WindowsAll versions—cvelist
Siemens SIMATIC PCS neoAll versions < V3.0 SP1—cvelist
Siemens SIMATIC STEP 7 (TIA Portal) V15All versions < V15.1 Update 5—cvelist
Siemens SIMATIC STEP 7 (TIA Portal) V16All versions < V16 Update 2—cvelist
Siemens SIMOCODE ES V15.1All versions < V15.1 Update 4—cvelist
Siemens SIMOCODE ES V16All versions < V16 Update 1—cvelist
Siemens Soft Starter ES V15.1All versions < V15.1 Update 3—cvelist
Siemens Soft Starter ES V16All versions < V16 Update 1—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2020-7581. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2020-7581.md
Affected: Siemens Opcenter Execution Discrete All versions < V3.2; Siemens Opcenter Execution Foundation All versions < V3.2; Siemens Opcenter Execution Process All versions < V3.2; Siemens Opcenter Intelligence All versions < V3.3; Siemens Opcenter Quality All versions < V11.3; Siemens Opcenter RD&L V8.0; S…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens Opcenter Execution Discrete, Siemens Opcenter Execution Foundation, Siemens Opcenter Execution Process, Siemens Opcenter Intelligence, Siemens Opcenter Quality, Siemens Opcenter RD&L: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2020-7581 being exploited?

There is no confirmed exploitation: CVE-2020-7581 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.38% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2020-7581?

Medium: CVSS 6.7 (v3.1, scored by NVD). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2020-7581?

Siemens Opcenter Execution Discrete All versions < V3.2; Siemens Opcenter Execution Foundation All versions < V3.2; Siemens Opcenter Execution Process All versions < V3.2; Siemens Opcenter Intelligence All versions < V3.3; Siemens Opcenter Quality All versions < V11.3; Siemens Opcenter RD&L V8.0; Siemens SIMATIC Notifier Server for Windows All versions; Siemens SIMATIC PCS neo All versions < V3.0 SP1; Siemens SIMATIC STEP 7 (TIA Portal) V15 All versions < V15.1 Update 5; Siemens SIMATIC STEP 7 (TIA Portal) V16 All versions < V16 Update 2; Siemens SIMOCODE ES V15.1 All versions < V15.1 Update 4; Siemens SIMOCODE ES V16 All versions < V16 Update 1; Siemens Soft Starter ES V15.1 All versions < V15.1 Update 3; Siemens Soft Starter ES V16 All versions < V16 Update 1.

Is there a fix for CVE-2020-7581?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2020-7581?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors