CVE-2020-7478
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the s…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running IGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009) IGSS (Interactive Graphical SCADA System) (Versions 14 and prior using the service: IGSSupdate)
Vulnerability facts
- Affected
- IGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009) IGSS (Interactive Graphical SCADA System) (Versions 14 and prior using the service: IGSSupdate)
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 7.5 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: None
- Availability impact: None
- EPSS
- 4.07% chance of exploitation in 30 days (percentile 91, 2026-11-26)
- CWE
- CWE-22
- Modified
Description
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a remote unauthenticated attacker to read arbitrary files from the IGSS server PC on an unrestricted or shared network when the IGSS Update Service is enabled.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| IGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009) | IGSS (Interactive Graphical SCADA System) (Versions 14 and prior using the service: IGSSupdate) | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2020-7478. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2020-7478.md Affected: IGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009) IGSS (Interactive Graphical SCADA System) (Versions 14 and prior using the service: IGSSupdate) Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for IGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009): dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2020-7478 being exploited?
There is no confirmed exploitation: CVE-2020-7478 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 4.07% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2020-7478?
High: CVSS 7.5 (v3.1, scored by NVD). Remote, no login needed.
Which versions are affected by CVE-2020-7478?
IGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009) IGSS (Interactive Graphical SCADA System) (Versions 14 and prior using the service: IGSSupdate).
Is there a fix for CVE-2020-7478?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2020-7478?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.