CVE-2020-6967
In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platfo…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Rockwell Automation All versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform Rockwell Automation All versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform
Vulnerability facts
- Affected
- Rockwell Automation All versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform Rockwell Automation All versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 9.8 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 5.50% chance of exploitation in 30 days (percentile 94, 2026-11-26)
- CWE
- CWE-502
- Modified
Description
In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Rockwell Automation All versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform | Rockwell Automation All versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2020-6967. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2020-6967.md Affected: Rockwell Automation All versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform Rockwell Automation All versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Rockwell Automation All versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2020-6967 being exploited?
There is no confirmed exploitation: CVE-2020-6967 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 5.50% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2020-6967?
Critical: CVSS 9.8 (v3.1, scored by NVD). Remote, no login needed.
Which versions are affected by CVE-2020-6967?
Rockwell Automation All versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform Rockwell Automation All versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform.
Is there a fix for CVE-2020-6967?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2020-6967?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.