CVE-2020-5807
An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the Facto…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Rockwell FactoryTalk Diagnostics All versions of FactoryTalk Diagnostics
Vulnerability facts
- Affected
- Rockwell FactoryTalk Diagnostics All versions of FactoryTalk Diagnostics
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 7.5 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- EPSS
- 39.30% chance of exploitation in 30 days (percentile 99, 2026-11-26)
- CWE
- CWE-755
- Modified
Description
An unauthenticated remote attacker can send data to RsvcHost.exe listening on TCP port 5241 to add entries in the FactoryTalk Diagnostics event log. The attacker can specify long fields in the log entry, which can cause an unhandled exception in wcscpy_s() if a local user opens FactoryTalk Diagnostics Viewer (FTDiagViewer.exe) to view the log entry. Observed in FactoryTalk Diagnostics 6.11. All versions of FactoryTalk Diagnostics are affected.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Rockwell FactoryTalk Diagnostics | All versions of FactoryTalk Diagnostics | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2020-5807. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2020-5807.md Affected: Rockwell FactoryTalk Diagnostics All versions of FactoryTalk Diagnostics Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Rockwell FactoryTalk Diagnostics: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2020-5807 being exploited?
There is no confirmed exploitation: CVE-2020-5807 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 39.30% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2020-5807?
High: CVSS 7.5 (v3.1, scored by NVD). Remote, no login needed.
Which versions are affected by CVE-2020-5807?
Rockwell FactoryTalk Diagnostics All versions of FactoryTalk Diagnostics.
Is there a fix for CVE-2020-5807?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2020-5807?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.