CVE-2020-3531
Cisco IoT Field Network Director Unauthenticated REST API Vulnerability
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Cisco IoT Field Network Director (IoT-FND) (versions: see the vendor advisory)
Vulnerability facts
- Affected
- Cisco IoT Field Network Director (IoT-FND)
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 9.8 (v3.0, CNA)CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 2.20% chance of exploitation in 30 days (percentile 83, 2026-11-26)
- CWE
- CWE-306
- Modified
Description
A vulnerability in the REST API of Cisco IoT Field Network Director (FND) could allow an unauthenticated, remote attacker to access the back-end database of an affected system. The vulnerability exists because the affected software does not properly authenticate REST API calls. An attacker could exploit this vulnerability by obtaining a cross-site request forgery (CSRF) token and then using the token with REST API requests. A successful exploit could allow the attacker to access the back-end database of the affected device and read, alter, or drop information.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Cisco IoT Field Network Director (IoT-FND) | — | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2020-3531. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2020-3531.md Affected: Cisco IoT Field Network Director (IoT-FND) Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Cisco IoT Field Network Director (IoT-FND): dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2020-3531 being exploited?
There is no confirmed exploitation: CVE-2020-3531 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.20% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2020-3531?
Critical: CVSS 9.8 (v3.0, scored by CNA). Remote, no login needed.
Which versions are affected by CVE-2020-3531?
Cisco IoT Field Network Director (IoT-FND).
Is there a fix for CVE-2020-3531?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2020-3531?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.