# CVE-2020-24686: AC500 V2 webserver denial of service vulnerability

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 7.5
- **CVSS:** 7.5 (v3.1, CNA) `CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: None; Integrity impact: None; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 2.61% (percentile 86, 2026-11-26)
- **CWE:** CWE-400
- **Published:** 2021-02-26T15:10:58.000Z
- **Modified:** 2026-06-17T03:05:59.200Z

## Who should check

- Anyone running ABB AC500 V2 products with onboard Ethernet All

## Description

The vulnerabilities can be exploited to cause the web visualization component of the PLC to stop and not respond, leading to genuine users losing remote visibility of the PLC state. If a user attempts to login to the PLC while this vulnerability is exploited, the PLC will show an error state and refuse connections to Automation Builder. The execution of the PLC application is not affected by this vulnerability. This issue affects ABB AC500 V2 products with onboard Ethernet.

## Affected and fixed versions

- ABB AC500 V2 products with onboard Ethernet: All (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2020-24686. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2020-24686.md
Affected: ABB AC500 V2 products with onboard Ethernet All
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for ABB AC500 V2 products with onboard Ethernet: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2020-24686 being exploited?

There is no confirmed exploitation: CVE-2020-24686 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.61% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2020-24686?

High: CVSS 7.5 (v3.1, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2020-24686?

ABB AC500 V2 products with onboard Ethernet All.

### Is there a fix for CVE-2020-24686?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2020-24686?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://search.abb.com/library/Download.aspx?DocumentID=3ADR010645&LanguageCode=en&DocumentPartId=&Action=Launch>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2020-24686>

HTML: <https://flawdb.com/CVE-2020-24686> · JSON: <https://flawdb.com/api/v1/entries/CVE-2020-24686>
