# CVE-2020-24682: Automation Studio and PVI Multiple unquoted service path vulnerabilities

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 7.2
- **CVSS:** 7.2 (v3.1, CNA) `CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H`
- **CVSS metrics:** Attack vector: Local; Attack complexity: High; Privileges required: High; User interaction: Required; Scope: Changed (impact reaches other components); Confidentiality impact: High; Integrity impact: High; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.15% (percentile 2, 2026-11-26)
- **CWE:** CWE-428
- **Published:** 2024-02-02T07:11:44.086Z
- **Modified:** 2026-06-17T03:05:58.727Z

## Who should check

- Anyone running B&R Industrial Automation Automation Studio \>= 4.0, \<= 4.6; \>= 4.7.0, \< 4.7.7 SP; \>= 4.8.0, \< 4.8.6 SP; \>= 4.9.0, \< 4.9.4 SP
- Anyone running B&R Industrial Automation NET/PVI \>= 4.0, \<= 4.6; \>= 4.7.0, \< 4.7.7; \>= 4.8.0, \< 4.8.6; \>= 4.9.0, \< 4.9.4

## Description

Unquoted Search Path or Element vulnerability in B&R Industrial Automation Automation Studio, B&R Industrial Automation NET/PVI allows Target Programs with Elevated Privileges.This issue affects Automation Studio: from 4.0 through 4.6, from 4.7.0 before 4.7.7 SP, from 4.8.0 before 4.8.6 SP, from 4.9.0 before 4.9.4 SP; NET/PVI: from 4.0 through 4.6, from 4.7.0 before 4.7.7, from 4.8.0 before 4.8.6, from 4.9.0 before 4.9.4.

## Affected and fixed versions

- B&R Industrial Automation Automation Studio: \>= 4.0, \<= 4.6; \>= 4.7.0, \< 4.7.7 SP; \>= 4.8.0, \< 4.8.6 SP; \>= 4.9.0, \< 4.9.4 SP (cvelist)
- B&R Industrial Automation NET/PVI: \>= 4.0, \<= 4.6; \>= 4.7.0, \< 4.7.7; \>= 4.8.0, \< 4.8.6; \>= 4.9.0, \< 4.9.4 (cvelist)

## Mitigation

- Upgrade NET/PVI to 4.9.4 or later.
- Vendor workaround: B&R has identified the following specific workarounds and mitigations.
- Users of B&R Automation Studio and PVI may manually reconfigure the service paths and enclose them 
- in quotes.
- Additionally, it is recommended to limit access to the workstation running B&R Automation Studio and PVI 
- to authorized users

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2020-24682. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2020-24682.md
Affected: B&R Industrial Automation Automation Studio >= 4.0, <= 4.6; >= 4.7.0, < 4.7.7 SP; >= 4.8.0, < 4.8.6 SP; >= 4.9.0, < 4.9.4 SP; B&R Industrial Automation NET/PVI >= 4.0, <= 4.6; >= 4.7.0, < 4.7.7; >= 4.8.0, < 4.8.6; >= 4.9.0, < 4.9.4
Fixed in: B&R Industrial Automation Automation Studio 4.7.7, B&R Industrial Automation Automation Studio 4.8.6, B&R Industrial Automation Automation Studio 4.9.4, B&R Industrial Automation NET/PVI 4.7.7, B&R Industrial Automation NET/PVI 4.8.6, B&R Industrial Automation NET/PVI 4.9.4

Steps:
1. Search this machine and project for B&R Industrial Automation Automation Studio, B&R Industrial Automation NET/PVI: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2020-24682 being exploited?

There is no confirmed exploitation: CVE-2020-24682 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.15% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2020-24682?

High: CVSS 7.2 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed). A user has to take an action, such as opening a link, for the attack to work. The attack needs conditions outside the attacker's control, which makes it harder.

### Which versions are affected by CVE-2020-24682?

B&R Industrial Automation Automation Studio \>= 4.0, \<= 4.6; \>= 4.7.0, \< 4.7.7 SP; \>= 4.8.0, \< 4.8.6 SP; \>= 4.9.0, \< 4.9.4 SP; B&R Industrial Automation NET/PVI \>= 4.0, \<= 4.6; \>= 4.7.0, \< 4.7.7; \>= 4.8.0, \< 4.8.6; \>= 4.9.0, \< 4.9.4.

### Is there a fix for CVE-2020-24682?

Yes. Fixed in B&R Industrial Automation Automation Studio 4.7.7, B&R Industrial Automation Automation Studio 4.8.6, B&R Industrial Automation Automation Studio 4.9.4, B&R Industrial Automation NET/PVI 4.7.7, B&R Industrial Automation NET/PVI 4.8.6, B&R Industrial Automation NET/PVI 4.9.4. Upgrade NET/PVI to 4.9.4 or later. Vendor workaround: B&R has identified the following specific workarounds and mitigations. Users of B&R Automation Studio and PVI may manually reconfigure the service paths and enclose them  in quotes. Additionally, it is recommended to limit access to the workstation running B&R Automation Studio and PVI  to authorized users

### How do I check if I'm affected by CVE-2020-24682?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://www.br-automation.com/fileadmin/2021-14-BR-AS-NET-PVI-Service-Issues-c3710fbf.pdf>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2020-24682>

HTML: <https://flawdb.com/CVE-2020-24682> · JSON: <https://flawdb.com/api/v1/entries/CVE-2020-24682>