CVE-2020-24588
The 802.11 standard that underpins Wi-Fi Protected Access (WPA, WPA2, and WPA3) and Wired Equivalent Privacy (WEP) does…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running n/a (versions: see the vendor advisory)
- Anyone running Siemens SCALANCE W1748-1 M12 < V3.0.0
- Anyone running Siemens SCALANCE W1750D (JP) < V8.7.1.3
- Anyone running Siemens SCALANCE W1750D (ROW) < V8.7.1.3
- Anyone running Siemens SCALANCE W1750D (USA) < V8.7.1.3
- Anyone running Siemens SCALANCE W1788-1 M12 < V3.0.0
- Anyone running Siemens SCALANCE W1788-2 EEC M12 < V3.0.0
- Anyone running Siemens SCALANCE W1788-2 M12 < V3.0.0
Vulnerability facts
- Affected
- n/a; Siemens SCALANCE W1748-1 M12 < V3.0.0; Siemens SCALANCE W1748-1 M12 < V3.0.0; Siemens SCALANCE W1750D (JP) < V8.7.1.3; Siemens SCALANCE W1750D (ROW) < V8.7.1.3; Siemens SCALANCE W1750D (USA) < V8.7.1.3; Siemens SCALANCE W1788-1 M12 < V3.0.0; Siemens SCALANCE W1788-2 EEC M12 < V3.0.0; Siemens SCALANCE W1788-2 M12 < V3.0.0; Siemens SCALANCE W1788-2IA M12 < V3.0.0; Siemens SCALANCE W721-1 RJ45 < V6.6.0; Siemens SCALANCE W721-1 RJ45 < V6.6.0; Siemens SCALANCE W721-1 RJ45 < V6.6.0; Siemens SCALANCE W721-1 RJ45 < V6.6.0; Siemens SCALANCE W722-1 RJ45 < V6.6.0; Siemens SCALANCE W722-1 RJ45 < V6.6.0; Siemens SCALANCE W722-1 RJ45 < V6.6.0; Siemens SCALANCE W722-1 RJ45 < V6.6.0; Siemens SCALANCE W722-1 RJ45 < V6.6.0; Siemens SCALANCE W722-1 RJ45 < V6.6.0; Siemens SCALANCE W734-1 RJ45 < V6.6.0; Siemens SCALANCE W734-1 RJ45 < V6.6.0; Siemens SCALANCE W734-1 RJ45 < V6.6.0; Siemens SCALANCE W734-1 RJ45 < V6.6.0; Siemens SCALANCE W734-1 RJ45 < V6.6.0; Siemens SCALANCE W734-1 RJ45 < V6.6.0; Siemens SCALANCE W734-1 RJ45 (USA) < V6.6.0; Siemens SCALANCE W734-1 RJ45 (USA) < V6.6.0; Siemens SCALANCE W738-1 M12 < V6.6.0; Siemens SCALANCE W738-1 M12 < V6.6.0; Siemens SCALANCE W738-1 M12 < V6.6.0; Siemens SCALANCE W738-1 M12 < V6.6.0; Siemens SCALANCE W748-1 M12 < V6.6.0; Siemens SCALANCE W748-1 M12 < V6.6.0; Siemens SCALANCE W748-1 M12 < V6.6.0; Siemens SCALANCE W748-1 M12 < V6.6.0; Siemens SCALANCE W748-1 RJ45 < V6.6.0; Siemens SCALANCE W748-1 RJ45 < V6.6.0; Siemens SCALANCE W748-1 RJ45 < V6.6.0; Siemens SCALANCE W748-1 RJ45 < V6.6.0; Siemens SCALANCE W761-1 RJ45 < V6.6.0; Siemens SCALANCE W761-1 RJ45 < V6.6.0; Siemens SCALANCE W761-1 RJ45 < V6.6.0; Siemens SCALANCE W761-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 M12 EEC < V6.6.0; Siemens SCALANCE W774-1 M12 EEC < V6.6.0; Siemens SCALANCE W774-1 M12 EEC < V6.6.0; Siemens SCALANCE W774-1 M12 EEC < V6.6.0; Siemens SCALANCE W774-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 RJ45 (USA) < V6.6.0; Siemens SCALANCE W774-1 RJ45 (USA) < V6.6.0; Siemens SCALANCE W778-1 M12 < V6.6.0; Siemens SCALANCE W778-1 M12 < V6.6.0; Siemens SCALANCE W778-1 M12 < V6.6.0; Siemens SCALANCE W778-1 M12 < V6.6.0; Siemens SCALANCE W778-1 M12 EEC < V6.6.0; Siemens SCALANCE W778-1 M12 EEC < V6.6.0; Siemens SCALANCE W778-1 M12 EEC (USA) < V6.6.0; Siemens SCALANCE W778-1 M12 EEC (USA) < V6.6.0; Siemens SCALANCE W786-1 RJ45 < V6.6.0; Siemens SCALANCE W786-1 RJ45 < V6.6.0; Siemens SCALANCE W786-1 RJ45 < V6.6.0; Siemens SCALANCE W786-1 RJ45 < V6.6.0; Siemens SCALANCE W786-2 RJ45 < V6.6.0; Siemens SCALANCE W786-2 RJ45 < V6.6.0; Siemens SCALANCE W786-2 RJ45 < V6.6.0; Siemens SCALANCE W786-2 RJ45 < V6.6.0; Siemens SCALANCE W786-2 RJ45 < V6.6.0; Siemens SCALANCE W786-2 RJ45 < V6.6.0; Siemens SCALANCE W786-2 SFP < V6.6.0; Siemens SCALANCE W786-2 SFP < V6.6.0; Siemens SCALANCE W786-2 SFP < V6.6.0; Siemens SCALANCE W786-2 SFP < V6.6.0; Siemens SCALANCE W786-2IA RJ45 < V6.6.0; Siemens SCALANCE W786-2IA RJ45 < V6.6.0; Siemens SCALANCE W786-2IA RJ45 < V6.6.0; Siemens SCALANCE W786-2IA RJ45 < V6.6.0; Siemens SCALANCE W788-1 M12 < V6.6.0; Siemens SCALANCE W788-1 M12 < V6.6.0; Siemens SCALANCE W788-1 M12 < V6.6.0; Siemens SCALANCE W788-1 M12 < V6.6.0; Siemens SCALANCE W788-1 RJ45 < V6.6.0; Siemens SCALANCE W788-1 RJ45 < V6.6.0; Siemens SCALANCE W788-1 RJ45 < V6.6.0; Siemens SCALANCE W788-1 RJ45 < V6.6.0; Siemens SCALANCE W788-2 M12 < V6.6.0; Siemens SCALANCE W788-2 M12 < V6.6.0; Siemens SCALANCE W788-2 M12 < V6.6.0; Siemens SCALANCE W788-2 M12 < V6.6.0; Siemens SCALANCE W788-2 M12 EEC < V6.6.0; Siemens SCALANCE W788-2 M12 EEC < V6.6.0; Siemens SCALANCE W788-2 M12 EEC < V6.6.0; Siemens SCALANCE W788-2 M12 EEC < V6.6.0; Siemens SCALANCE W788-2 M12 EEC < V6.6.0; Siemens SCALANCE W788-2 M12 EEC < V6.6.0; Siemens SCALANCE W788-2 RJ45 < V6.6.0; Siemens SCALANCE W788-2 RJ45 < V6.6.0; Siemens SCALANCE W788-2 RJ45 < V6.6.0; Siemens SCALANCE W788-2 RJ45 < V6.6.0; Siemens SCALANCE W788-2 RJ45 < V6.6.0; Siemens SCALANCE W788-2 RJ45 < V6.6.0; Siemens SCALANCE WAM763-1 < V1.2.0; Siemens SCALANCE WAM766-1 < V1.2.0; Siemens SCALANCE WAM766-1 (US) < V1.2.0; Siemens SCALANCE WAM766-1 EEC < V1.2.0; Siemens SCALANCE WAM766-1 EEC (US) < V1.2.0; Siemens SCALANCE WUM763-1 < V1.2.0; Siemens SCALANCE WUM763-1 < V1.2.0; Siemens SCALANCE WUM766-1 < V1.2.0; Siemens SCALANCE WUM766-1 (USA) < V1.2.0
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- Yes: see the exploit references below
- Remote exploitation
- Not remotely exploitable (local or adjacent access needed)
- CVSS
- 3.5 (v3.1, NVD)CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Adjacent network
- Attack complexity: Low
- Privileges required: None
- User interaction: Required
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: Low
- Availability impact: None
- EPSS
- 3.61% chance of exploitation in 30 days (percentile 90, 2026-11-26)
- CWE
- CWE-327
- Modified
Description
The 802.11 standard that underpins Wi-Fi Protected Access (WPA, WPA2, and WPA3) and Wired Equivalent Privacy (WEP) doesn't require that the A-MSDU flag in the plaintext QoS header field is authenticated. Against devices that support receiving non-SSP A-MSDU frames (which is mandatory as part of 802.11n), an adversary can abuse this to inject arbitrary network packets.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| n/a | — | — | nvd |
| Siemens SCALANCE W1748-1 M12 | < V3.0.0 | — | nvd |
| Siemens SCALANCE W1748-1 M12 | < V3.0.0 | — | nvd |
| Siemens SCALANCE W1750D (JP) | < V8.7.1.3 | — | nvd |
| Siemens SCALANCE W1750D (ROW) | < V8.7.1.3 | — | nvd |
| Siemens SCALANCE W1750D (USA) | < V8.7.1.3 | — | nvd |
| Siemens SCALANCE W1788-1 M12 | < V3.0.0 | — | nvd |
| Siemens SCALANCE W1788-2 EEC M12 | < V3.0.0 | — | nvd |
| Siemens SCALANCE W1788-2 M12 | < V3.0.0 | — | nvd |
| Siemens SCALANCE W1788-2IA M12 | < V3.0.0 | — | nvd |
| Siemens SCALANCE W721-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W721-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W721-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W721-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W722-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W722-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W722-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W722-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W722-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W722-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W734-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W734-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W734-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W734-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W734-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W734-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W734-1 RJ45 (USA) | < V6.6.0 | — | nvd |
| Siemens SCALANCE W734-1 RJ45 (USA) | < V6.6.0 | — | nvd |
| Siemens SCALANCE W738-1 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W738-1 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W738-1 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W738-1 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W748-1 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W748-1 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W748-1 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W748-1 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W748-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W748-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W748-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W748-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W761-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W761-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W761-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W761-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W774-1 M12 EEC | < V6.6.0 | — | nvd |
| Siemens SCALANCE W774-1 M12 EEC | < V6.6.0 | — | nvd |
| Siemens SCALANCE W774-1 M12 EEC | < V6.6.0 | — | nvd |
| Siemens SCALANCE W774-1 M12 EEC | < V6.6.0 | — | nvd |
| Siemens SCALANCE W774-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W774-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W774-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W774-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W774-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W774-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W774-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W774-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W774-1 RJ45 (USA) | < V6.6.0 | — | nvd |
| Siemens SCALANCE W774-1 RJ45 (USA) | < V6.6.0 | — | nvd |
| Siemens SCALANCE W778-1 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W778-1 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W778-1 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W778-1 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W778-1 M12 EEC | < V6.6.0 | — | nvd |
| Siemens SCALANCE W778-1 M12 EEC | < V6.6.0 | — | nvd |
| Siemens SCALANCE W778-1 M12 EEC (USA) | < V6.6.0 | — | nvd |
| Siemens SCALANCE W778-1 M12 EEC (USA) | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-2 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-2 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-2 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-2 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-2 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-2 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-2 SFP | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-2 SFP | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-2 SFP | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-2 SFP | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-2IA RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-2IA RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-2IA RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W786-2IA RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-1 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-1 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-1 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-1 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-1 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-2 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-2 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-2 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-2 M12 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-2 M12 EEC | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-2 M12 EEC | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-2 M12 EEC | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-2 M12 EEC | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-2 M12 EEC | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-2 M12 EEC | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-2 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-2 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-2 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-2 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-2 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE W788-2 RJ45 | < V6.6.0 | — | nvd |
| Siemens SCALANCE WAM763-1 | < V1.2.0 | — | nvd |
| Siemens SCALANCE WAM766-1 | < V1.2.0 | — | nvd |
| Siemens SCALANCE WAM766-1 (US) | < V1.2.0 | — | nvd |
| Siemens SCALANCE WAM766-1 EEC | < V1.2.0 | — | nvd |
| Siemens SCALANCE WAM766-1 EEC (US) | < V1.2.0 | — | nvd |
| Siemens SCALANCE WUM763-1 | < V1.2.0 | — | nvd |
| Siemens SCALANCE WUM763-1 | < V1.2.0 | — | nvd |
| Siemens SCALANCE WUM766-1 | < V1.2.0 | — | nvd |
| Siemens SCALANCE WUM766-1 (USA) | < V1.2.0 | — | nvd |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2020-24588. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2020-24588.md Affected: n/a; Siemens SCALANCE W1748-1 M12 < V3.0.0; Siemens SCALANCE W1748-1 M12 < V3.0.0; Siemens SCALANCE W1750D (JP) < V8.7.1.3; Siemens SCALANCE W1750D (ROW) < V8.7.1.3; Siemens SCALANCE W1750D (USA) < V8.7.1.3; Siemens SCALANCE W1788-1 M12 < V3.0.0; Siemens SCALANCE W1788-2 EEC M12 < V3.0.0; Siemens S… Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for n/a, Siemens SCALANCE W1748-1 M12, Siemens SCALANCE W1750D (JP), Siemens SCALANCE W1750D (ROW), Siemens SCALANCE W1750D (USA), Siemens SCALANCE W1788-1 M12: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
Exploits and PoCs
Other
- https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00473.html
- https://github.com/vanhoefm/fragattacks/blob/master/SUMMARY.md
- http://www.openwall.com/lists/oss-security/2021/05/11/12
- https://lists.debian.org/debian-lts-announce/2021/06/msg00020.html
- https://lists.debian.org/debian-lts-announce/2021/06/msg00019.html
- https://cert-portal.siemens.com/productcert/pdf/ssa-913875.pdf
- https://www.arista.com/en/support/advisories-notices/security-advisories/12602-security-advisory-63
- https://lists.debian.org/debian-lts-announce/2023/04/msg00002.html
- https://cert-portal.siemens.com/productcert/html/ssa-913875.html
- https://cert-portal.siemens.com/productcert/html/ssa-019200.html
FAQ
Is CVE-2020-24588 being exploited?
There is no confirmed exploitation: CVE-2020-24588 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 3.61% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2020-24588?
Low: CVSS 3.5 (v3.1, scored by NVD). Not remotely exploitable (local or adjacent access needed). A user has to take an action, such as opening a link, for the attack to work.
Which versions are affected by CVE-2020-24588?
n/a; Siemens SCALANCE W1748-1 M12 < V3.0.0; Siemens SCALANCE W1748-1 M12 < V3.0.0; Siemens SCALANCE W1750D (JP) < V8.7.1.3; Siemens SCALANCE W1750D (ROW) < V8.7.1.3; Siemens SCALANCE W1750D (USA) < V8.7.1.3; Siemens SCALANCE W1788-1 M12 < V3.0.0; Siemens SCALANCE W1788-2 EEC M12 < V3.0.0; Siemens SCALANCE W1788-2 M12 < V3.0.0; Siemens SCALANCE W1788-2IA M12 < V3.0.0; Siemens SCALANCE W721-1 RJ45 < V6.6.0; Siemens SCALANCE W721-1 RJ45 < V6.6.0; Siemens SCALANCE W721-1 RJ45 < V6.6.0; Siemens SCALANCE W721-1 RJ45 < V6.6.0; Siemens SCALANCE W722-1 RJ45 < V6.6.0; Siemens SCALANCE W722-1 RJ45 < V6.6.0; Siemens SCALANCE W722-1 RJ45 < V6.6.0; Siemens SCALANCE W722-1 RJ45 < V6.6.0; Siemens SCALANCE W722-1 RJ45 < V6.6.0; Siemens SCALANCE W722-1 RJ45 < V6.6.0; Siemens SCALANCE W734-1 RJ45 < V6.6.0; Siemens SCALANCE W734-1 RJ45 < V6.6.0; Siemens SCALANCE W734-1 RJ45 < V6.6.0; Siemens SCALANCE W734-1 RJ45 < V6.6.0; Siemens SCALANCE W734-1 RJ45 < V6.6.0; Siemens SCALANCE W734-1 RJ45 < V6.6.0; Siemens SCALANCE W734-1 RJ45 (USA) < V6.6.0; Siemens SCALANCE W734-1 RJ45 (USA) < V6.6.0; Siemens SCALANCE W738-1 M12 < V6.6.0; Siemens SCALANCE W738-1 M12 < V6.6.0; Siemens SCALANCE W738-1 M12 < V6.6.0; Siemens SCALANCE W738-1 M12 < V6.6.0; Siemens SCALANCE W748-1 M12 < V6.6.0; Siemens SCALANCE W748-1 M12 < V6.6.0; Siemens SCALANCE W748-1 M12 < V6.6.0; Siemens SCALANCE W748-1 M12 < V6.6.0; Siemens SCALANCE W748-1 RJ45 < V6.6.0; Siemens SCALANCE W748-1 RJ45 < V6.6.0; Siemens SCALANCE W748-1 RJ45 < V6.6.0; Siemens SCALANCE W748-1 RJ45 < V6.6.0; Siemens SCALANCE W761-1 RJ45 < V6.6.0; Siemens SCALANCE W761-1 RJ45 < V6.6.0; Siemens SCALANCE W761-1 RJ45 < V6.6.0; Siemens SCALANCE W761-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 M12 EEC < V6.6.0; Siemens SCALANCE W774-1 M12 EEC < V6.6.0; Siemens SCALANCE W774-1 M12 EEC < V6.6.0; Siemens SCALANCE W774-1 M12 EEC < V6.6.0; Siemens SCALANCE W774-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 RJ45 < V6.6.0; Siemens SCALANCE W774-1 RJ45 (USA) < V6.6.0; Siemens SCALANCE W774-1 RJ45 (USA) < V6.6.0; Siemens SCALANCE W778-1 M12 < V6.6.0; Siemens SCALANCE W778-1 M12 < V6.6.0; Siemens SCALANCE W778-1 M12 < V6.6.0; Siemens SCALANCE W778-1 M12 < V6.6.0; Siemens SCALANCE W778-1 M12 EEC < V6.6.0; Siemens SCALANCE W778-1 M12 EEC < V6.6.0; Siemens SCALANCE W778-1 M12 EEC (USA) < V6.6.0; Siemens SCALANCE W778-1 M12 EEC (USA) < V6.6.0; Siemens SCALANCE W786-1 RJ45 < V6.6.0; Siemens SCALANCE W786-1 RJ45 < V6.6.0; Siemens SCALANCE W786-1 RJ45 < V6.6.0; Siemens SCALANCE W786-1 RJ45 < V6.6.0; Siemens SCALANCE W786-2 RJ45 < V6.6.0; Siemens SCALANCE W786-2 RJ45 < V6.6.0; Siemens SCALANCE W786-2 RJ45 < V6.6.0; Siemens SCALANCE W786-2 RJ45 < V6.6.0; Siemens SCALANCE W786-2 RJ45 < V6.6.0; Siemens SCALANCE W786-2 RJ45 < V6.6.0; Siemens SCALANCE W786-2 SFP < V6.6.0; Siemens SCALANCE W786-2 SFP < V6.6.0; Siemens SCALANCE W786-2 SFP < V6.6.0; Siemens SCALANCE W786-2 SFP < V6.6.0; Siemens SCALANCE W786-2IA RJ45 < V6.6.0; Siemens SCALANCE W786-2IA RJ45 < V6.6.0; Siemens SCALANCE W786-2IA RJ45 < V6.6.0; Siemens SCALANCE W786-2IA RJ45 < V6.6.0; Siemens SCALANCE W788-1 M12 < V6.6.0; Siemens SCALANCE W788-1 M12 < V6.6.0; Siemens SCALANCE W788-1 M12 < V6.6.0; Siemens SCALANCE W788-1 M12 < V6.6.0; Siemens SCALANCE W788-1 RJ45 < V6.6.0; Siemens SCALANCE W788-1 RJ45 < V6.6.0; Siemens SCALANCE W788-1 RJ45 < V6.6.0; Siemens SCALANCE W788-1 RJ45 < V6.6.0; Siemens SCALANCE W788-2 M12 < V6.6.0; Siemens SCALANCE W788-2 M12 < V6.6.0; Siemens SCALANCE W788-2 M12 < V6.6.0; Siemens SCALANCE W788-2 M12 < V6.6.0; Siemens SCALANCE W788-2 M12 EEC < V6.6.0; Siemens SCALANCE W788-2 M12 EEC < V6.6.0; Siemens SCALANCE W788-2 M12 EEC < V6.6.0; Siemens SCALANCE W788-2 M12 EEC < V6.6.0; Siemens SCALANCE W788-2 M12 EEC < V6.6.0; Siemens SCALANCE W788-2 M12 EEC < V6.6.0; Siemens SCALANCE W788-2 RJ45 < V6.6.0; Siemens SCALANCE W788-2 RJ45 < V6.6.0; Siemens SCALANCE W788-2 RJ45 < V6.6.0; Siemens SCALANCE W788-2 RJ45 < V6.6.0; Siemens SCALANCE W788-2 RJ45 < V6.6.0; Siemens SCALANCE W788-2 RJ45 < V6.6.0; Siemens SCALANCE WAM763-1 < V1.2.0; Siemens SCALANCE WAM766-1 < V1.2.0; Siemens SCALANCE WAM766-1 (US) < V1.2.0; Siemens SCALANCE WAM766-1 EEC < V1.2.0; Siemens SCALANCE WAM766-1 EEC (US) < V1.2.0; Siemens SCALANCE WUM763-1 < V1.2.0; Siemens SCALANCE WUM763-1 < V1.2.0; Siemens SCALANCE WUM766-1 < V1.2.0; Siemens SCALANCE WUM766-1 (USA) < V1.2.0.
Is there a fix for CVE-2020-24588?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2020-24588?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.