# CVE-2020-1654: Junos OS: SRX Series: processing a malformed HTTP message when ICAP redirect service is enabled may can lead to flowd process crash or remote code execution

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** CRITICAL 9.8
- **CVSS:** 9.8 (v3.1, CNA) `CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: High; Integrity impact: High; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 2.23% (percentile 83, 2026-11-26)
- **CWE:** CWE-120
- **Published:** 2020-07-17T18:40:45.036Z
- **Modified:** 2026-06-17T03:02:07.673Z

## Who should check

- Anyone running Juniper Networks Junos OS \>= 18.2, \< 18.2R2-S7, 18.2R3-S3; \>= 18.3, \< 18.3R1-S7, 18.3R2-S4, 18.3R3-S1; \>= 18.4, \< 18.4R1-S7, 18.4R2-S4, 18.4R3; \>= 19.1, \< 19.1R1-S5, 19.1R2; \>= 19.2, \< 19.2R1-S2, 19.2R2; \>= 19.3, \< 19.3R2

## Description

On Juniper Networks SRX Series with ICAP (Internet Content Adaptation Protocol) redirect service enabled, processing a malformed HTTP message can lead to a Denial of Service (DoS) or Remote Code Execution (RCE) Continued processing of this malformed HTTP message may result in an extended Denial of Service (DoS) condition. The offending HTTP message that causes this issue may originate both from the HTTP server or the HTTP client. This issue affects Juniper Networks Junos OS on SRX Series: 18.1 versions prior to 18.1R3-S9 ; 18.2 versions prior to 18.2R2-S7, 18.2R3-S3; 18.3 versions prior to 18.3R1-S7, 18.3R2-S4, 18.3R3-S1; 18.4 versions prior to 18.4R1-S7, 18.4R2-S4, 18.4R3; 19.1 versions prior to 19.1R1-S5, 19.1R2; 19.2 versions prior to 19.2R1-S2, 19.2R2; 19.3 versions prior to 19.3R2. This issue does not affect Juniper Networks Junos OS prior to 18.1R1.

## Affected and fixed versions

- Juniper Networks Junos OS: \>= 18.2, \< 18.2R2-S7, 18.2R3-S3; \>= 18.3, \< 18.3R1-S7, 18.3R2-S4, 18.3R3-S1; \>= 18.4, \< 18.4R1-S7, 18.4R2-S4, 18.4R3; \>= 19.1, \< 19.1R1-S5, 19.1R2; \>= 19.2, \< 19.2R1-S2, 19.2R2; \>= 19.3, \< 19.3R2 (cvelist)

## Mitigation

- Upgrade Junos OS to 19.3R2 or later.
- Vendor workaround: Disable ICAP redirect service otherwise there are no viable workarounds for this issue.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2020-1654. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2020-1654.md
Affected: Juniper Networks Junos OS >= 18.2, < 18.2R2-S7, 18.2R3-S3; >= 18.3, < 18.3R1-S7, 18.3R2-S4, 18.3R3-S1; >= 18.4, < 18.4R1-S7, 18.4R2-S4, 18.4R3; >= 19.1, < 19.1R1-S5, 19.1R2; >= 19.2, < 19.2R1-S2, 19.2R2; >= 19.3, < 19.3R2
Fixed in: Juniper Networks Junos OS 18.2R2-S7, Juniper Networks Junos OS 18.3R1-S7, Juniper Networks Junos OS 18.4R1-S7, Juniper Networks Junos OS 19.1R1-S5, Juniper Networks Junos OS 19.2R1-S2, Juniper Networks Junos OS 19.3R2

Steps:
1. Search this machine and project for Juniper Networks Junos OS: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2020-1654 being exploited?

There is no confirmed exploitation: CVE-2020-1654 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 2.23% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2020-1654?

Critical: CVSS 9.8 (v3.1, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2020-1654?

Juniper Networks Junos OS \>= 18.2, \< 18.2R2-S7, 18.2R3-S3; \>= 18.3, \< 18.3R1-S7, 18.3R2-S4, 18.3R3-S1; \>= 18.4, \< 18.4R1-S7, 18.4R2-S4, 18.4R3; \>= 19.1, \< 19.1R1-S5, 19.1R2; \>= 19.2, \< 19.2R1-S2, 19.2R2; \>= 19.3, \< 19.3R2.

### Is there a fix for CVE-2020-1654?

Yes. Fixed in Juniper Networks Junos OS 18.2R2-S7, Juniper Networks Junos OS 18.3R1-S7, Juniper Networks Junos OS 18.4R1-S7, Juniper Networks Junos OS 19.1R1-S5, Juniper Networks Junos OS 19.2R1-S2, Juniper Networks Junos OS 19.3R2. Upgrade Junos OS to 19.3R2 or later. Vendor workaround: Disable ICAP redirect service otherwise there are no viable workarounds for this issue.

### How do I check if I'm affected by CVE-2020-1654?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://kb.juniper.net/JSA11031>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2020-1654>

HTML: <https://flawdb.com/CVE-2020-1654> · JSON: <https://flawdb.com/api/v1/entries/CVE-2020-1654>