# CVE-2020-1617: Junos OS: PTX1000 and PTX10000 Series, QFX10000 Series using non-AFT architectures: A specific genuine packet inspected by sFlow will cause a reboot.

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 7.5
- **CVSS:** 7.5 (v3.1, CNA) `CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: None; Integrity impact: None; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 1.57% (percentile 76, 2026-11-26)
- **CWE:** CWE-665
- **Published:** 2020-04-08T19:25:54.368Z
- **Modified:** 2026-06-17T03:01:53.440Z

## Who should check

- Anyone running Juniper Networks Junos OS \>= 17.4, \< 17.4R2-S9, 17.4R3; \>= 18.1, \<= 18.1R3-S9; \>= 18.2X75, \< 18.2X75-D12, 18.2X75-D30; \>= 18.2, \< 18.2R3; \>= 18.3, \< 18.3R3

## Description

This issue occurs on Juniper Networks Junos OS devices which do not support Advanced Forwarding Interface (AFI) / Advanced Forwarding Toolkit (AFT). Devices using AFI and AFT are not exploitable to this issue. An improper initialization of memory in the packet forwarding architecture in Juniper Networks Junos OS non-AFI/AFT platforms which may lead to a Denial of Service (DoS) vulnerability being exploited when a genuine packet is received and inspected by non-AFT/AFI sFlow and when the device is also configured with firewall policers. This first genuine packet received and inspected by sampled flow (sFlow) through a specific firewall policer will cause the device to reboot. After the reboot has completed, if the device receives and sFlow inspects another genuine packet seen through a specific firewall policer, the device will generate a core file and reboot. Continued inspection of these genuine packets will create an extended Denial of Service (DoS) condition. Depending on the method for service restoration, e.g. hard boot or soft reboot, a core file may or may not be generated the next time the packet is received and inspected by sFlow. This issue affects: Juniper Networks Junos OS 17.4 versions prior to 17.4R2-S9, 17.4R3 on PTX1000 and PTX10000 Series, QFX10000 Series; 18.1 versions prior to 18.1R3-S9 on PTX1000 and PTX10000 Series, QFX10000 Series; 18.2X75 versions prior to 18.2X75-D12, 18.2X75-D30 on PTX1000 and PTX10000 Series, QFX10000 Series; 18.2 versions prior to 18.2R3 on PTX1000 and PTX10000 Series, QFX10000 Series; 18.3 versions prior to 18.3R3 on PTX1000 and PTX10000 Series, QFX10000 Series. This issue is not applicable to Junos OS versions before 17.4R1. This issue is not applicable to Junos OS Evolved or Junos OS with Advanced Forwarding Toolkit (AFT) forwarding implementations which use a different implementation of sFlow. The following example information is unrelated to this issue and is provided solely to assist you with determining if you have AFT or not. Example: A Junos OS device which supports the use of EVPN signaled VPWS with Flexible Cross Connect uses the AFT implementation. Since this configuration requires support and use of the AFT implementation to support this configuration, the device is not vulnerable to this issue as the sFlow implementation is different using the AFT architecture. For further details about AFT visit the AFI / AFT are in the links below. If you are uncertain if you use the AFI/AFT implementation or not, there are configuration examples in the links below which you may use to determine if you are vulnerable to this issue or not. If the commands work, you are. If not, you are not. You may also use the Feature Explorer to determine if AFI/AFT is supported or not. If you are still uncertain, please contact your support resources.

## Affected and fixed versions

- Juniper Networks Junos OS: \>= 17.4, \< 17.4R2-S9, 17.4R3; \>= 18.1, \<= 18.1R3-S9; \>= 18.2X75, \< 18.2X75-D12, 18.2X75-D30; \>= 18.2, \< 18.2R3; \>= 18.3, \< 18.3R3 (cvelist)

## Mitigation

- Upgrade Junos OS to 18.3R3 or later.
- Vendor workaround: Discontinue use of firewall policers.
- Or
- Discontinue use of sFlow.
- Or
- Both of the above.  It is not required to discontinue both to mitigate the issue.
- 
- There are no other available workarounds.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2020-1617. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2020-1617.md
Affected: Juniper Networks Junos OS >= 17.4, < 17.4R2-S9, 17.4R3; >= 18.1, <= 18.1R3-S9; >= 18.2X75, < 18.2X75-D12, 18.2X75-D30; >= 18.2, < 18.2R3; >= 18.3, < 18.3R3
Fixed in: Juniper Networks Junos OS 17.4R2-S9, Juniper Networks Junos OS 18.2X75-D12, Juniper Networks Junos OS 18.2R3, Juniper Networks Junos OS 18.3R3

Steps:
1. Search this machine and project for Juniper Networks Junos OS: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2020-1617 being exploited?

There is no confirmed exploitation: CVE-2020-1617 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.57% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2020-1617?

High: CVSS 7.5 (v3.1, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2020-1617?

Juniper Networks Junos OS \>= 17.4, \< 17.4R2-S9, 17.4R3; \>= 18.1, \<= 18.1R3-S9; \>= 18.2X75, \< 18.2X75-D12, 18.2X75-D30; \>= 18.2, \< 18.2R3; \>= 18.3, \< 18.3R3.

### Is there a fix for CVE-2020-1617?

Yes. Fixed in Juniper Networks Junos OS 17.4R2-S9, Juniper Networks Junos OS 18.2X75-D12, Juniper Networks Junos OS 18.2R3, Juniper Networks Junos OS 18.3R3. Upgrade Junos OS to 18.3R3 or later. Vendor workaround: Discontinue use of firewall policers. Or Discontinue use of sFlow. Or Both of the above.  It is not required to discontinue both to mitigate the issue.  There are no other available workarounds.

### How do I check if I'm affected by CVE-2020-1617?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://kb.juniper.net/JSA11000>
- vendor: <https://www.juniper.net/documentation/en_US/junos/topics/example/example-configuring-vpws-service-with-evpn-signaling-mechanisms.html>
- other: <https://github.com/Juniper/AFI>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2020-1617>

HTML: <https://flawdb.com/CVE-2020-1617> · JSON: <https://flawdb.com/api/v1/entries/CVE-2020-1617>