# CVE-2020-14525: Philips Clinical Collaboration Platform Improper Neutralization of Script in Attributes in a Web Page

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** LOW 3.5
- **CVSS:** 3.5 (v3.1, CNA) `CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N`
- **CVSS metrics:** Attack vector: Adjacent network; Attack complexity: Low; Privileges required: Low; User interaction: None; Scope: Unchanged; Confidentiality impact: Low; Integrity impact: None; Availability impact: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Not remotely exploitable (local or adjacent access needed)
- **EPSS:** 0.47% (percentile 33, 2026-11-26)
- **CWE:** CWE-83
- **Published:** 2020-09-18T17:48:30.000Z
- **Modified:** 2026-06-17T02:54:55.900Z

## Who should check

- Anyone running Philips Clinical Collaboration Platform \< 12.2.1

## Description

Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input 
before it is placed in output used as a webpage that is served to other 
users.

## Affected and fixed versions

- Philips Clinical Collaboration Platform: \< 12.2.1 (cvelist)

## Mitigation

- Upgrade Clinical Collaboration Platform to 12.2.1 or later.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2020-14525. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2020-14525.md
Affected: Philips Clinical Collaboration Platform < 12.2.1
Fixed in: Philips Clinical Collaboration Platform 12.2.1

Steps:
1. Search this machine and project for Philips Clinical Collaboration Platform: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2020-14525 being exploited?

There is no confirmed exploitation: CVE-2020-14525 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.47% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2020-14525?

Low: CVSS 3.5 (v3.1, scored by CNA). Not remotely exploitable (local or adjacent access needed).

### Which versions are affected by CVE-2020-14525?

Philips Clinical Collaboration Platform \< 12.2.1.

### Is there a fix for CVE-2020-14525?

Yes. Fixed in Philips Clinical Collaboration Platform 12.2.1. Upgrade Clinical Collaboration Platform to 12.2.1 or later.

### How do I check if I'm affected by CVE-2020-14525?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://us-cert.cisa.gov/ics/advisories/icsma-20-261-01>
- other: <https://www.philips.com/a-w/security/security-advisories/product-security-2020.html#2020_archive>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2020-14525>

HTML: <https://flawdb.com/CVE-2020-14525> · JSON: <https://flawdb.com/api/v1/entries/CVE-2020-14525>