CRITICAL 10.0EPSS 88%

Command Injection Vulnerability in I/O-Check Service of WAGO PFC100, PFC200 and Touch Panel 600 Series with firmware versions <=FW10

Mitigation

  • Vendor workaround: Disable I/O-Check service
  • Restrict network access to the device.
  • Do not directly connect the device to the internet.

Who should check

  • Anyone running WAGO Series PFC 100 (750-81xx/xxx-xxx) >= FW1, <= FW10
  • Anyone running WAGO Series PFC 200 (750-82xx/xxx-xxx) >= FW1, <= FW10
  • Anyone running Series Wago Touch Panel 600 Standard Line (762-4xxx) >= FW1, <= FW10
  • Anyone running Series Wago Touch Panel 600 Advanced Line (762-5xxx) >= FW1, <= FW10
  • Anyone running Series Wago Touch Panel 600 Marine Line (762-6xxx) >= FW1, <= FW10

Vulnerability facts

Affected
WAGO Series PFC 100 (750-81xx/xxx-xxx) >= FW1, <= FW10; WAGO Series PFC 200 (750-82xx/xxx-xxx) >= FW1, <= FW10; Series Wago Touch Panel 600 Standard Line (762-4xxx) >= FW1, <= FW10; Series Wago Touch Panel 600 Advanced Line (762-5xxx) >= FW1, <= FW10; Series Wago Touch Panel 600 Marine Line (762-6xxx) >= FW1, <= FW10
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
10.0 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Changed (impact reaches other components)
  • Confidentiality impact: High
  • Integrity impact: High
  • Availability impact: High
EPSS
3.05% chance of exploitation in 30 days (percentile 88, 2026-11-26)
CWE
CWE-78
Published
Modified

Description

The reported vulnerability allows an attacker who has network access to the device to execute code with specially crafted packets in WAGO Series PFC 100 (750-81xx/xxx-xxx), Series PFC 200 (750-82xx/xxx-xxx), Series Wago Touch Panel 600 Standard Line (762-4xxx), Series Wago Touch Panel 600 Advanced Line (762-5xxx), Series Wago Touch Panel 600 Marine Line (762-6xxx) with firmware versions <=FW10.

Affected and fixed versions

Package / productAffectedFixedSource
WAGO Series PFC 100 (750-81xx/xxx-xxx)>= FW1, <= FW10—cvelist
WAGO Series PFC 200 (750-82xx/xxx-xxx)>= FW1, <= FW10—cvelist
Series Wago Touch Panel 600 Standard Line (762-4xxx)>= FW1, <= FW10—cvelist
Series Wago Touch Panel 600 Advanced Line (762-5xxx)>= FW1, <= FW10—cvelist
Series Wago Touch Panel 600 Marine Line (762-6xxx)>= FW1, <= FW10—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2020-12522. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2020-12522.md
Affected: WAGO Series PFC 100 (750-81xx/xxx-xxx) >= FW1, <= FW10; WAGO Series PFC 200 (750-82xx/xxx-xxx) >= FW1, <= FW10; Series Wago Touch Panel 600 Standard Line (762-4xxx) >= FW1, <= FW10; Series Wago Touch Panel 600 Advanced Line (762-5xxx) >= FW1, <= FW10; Series Wago Touch Panel 600 Marine Line (762-6x…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for WAGO Series PFC 100 (750-81xx/xxx-xxx), WAGO Series PFC 200 (750-82xx/xxx-xxx), Series Wago Touch Panel 600 Standard Line (762-4xxx), Series Wago Touch Panel 600 Advanced Line (762-5xxx), Series Wago Touch Panel 600 Marine Line (762-6xxx): dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2020-12522 being exploited?

There is no confirmed exploitation: CVE-2020-12522 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 3.05% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2020-12522?

Critical: CVSS 10.0 (v3.1, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2020-12522?

WAGO Series PFC 100 (750-81xx/xxx-xxx) >= FW1, <= FW10; WAGO Series PFC 200 (750-82xx/xxx-xxx) >= FW1, <= FW10; Series Wago Touch Panel 600 Standard Line (762-4xxx) >= FW1, <= FW10; Series Wago Touch Panel 600 Advanced Line (762-5xxx) >= FW1, <= FW10; Series Wago Touch Panel 600 Marine Line (762-6xxx) >= FW1, <= FW10.

Is there a fix for CVE-2020-12522?

No fixed version is listed in the sources yet. Vendor workaround: Disable I/O-Check service Restrict network access to the device. Do not directly connect the device to the internet.

How do I check if I'm affected by CVE-2020-12522?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors