CVE-2019-6569

CRITICAL 9.1EPSS 71%

The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens SCALANCE X204-2 All versions < V5.2.6
  • Anyone running Siemens SCALANCE X204-2FM All versions < V5.2.6
  • Anyone running Siemens SCALANCE X204-2LD All versions < V5.2.6
  • Anyone running Siemens SCALANCE X204-2LD TS All versions < V5.2.6
  • Anyone running Siemens SCALANCE X204-2TS All versions < V5.2.6
  • Anyone running Siemens SCALANCE X206-1 All versions < V5.2.6
  • Anyone running Siemens SCALANCE X206-1LD All versions < V5.2.6
  • Anyone running Siemens SCALANCE X208 All versions < V5.2.6

Vulnerability facts

Affected
Siemens SCALANCE X204-2 All versions < V5.2.6; Siemens SCALANCE X204-2FM All versions < V5.2.6; Siemens SCALANCE X204-2LD All versions < V5.2.6; Siemens SCALANCE X204-2LD TS All versions < V5.2.6; Siemens SCALANCE X204-2TS All versions < V5.2.6; Siemens SCALANCE X206-1 All versions < V5.2.6; Siemens SCALANCE X206-1LD All versions < V5.2.6; Siemens SCALANCE X208 All versions < V5.2.6; Siemens SCALANCE X208PRO All versions < V5.2.6; Siemens SCALANCE X212-2 All versions < V5.2.6; Siemens SCALANCE X212-2LD All versions < V5.2.6; Siemens SCALANCE X216 All versions < V5.2.6; Siemens SCALANCE X224 All versions < V5.2.6; Siemens SCALANCE X302-7 EEC (230V) All versions < V4.1.3; Siemens SCALANCE X302-7 EEC (230V, coated) All versions < V4.1.3; Siemens SCALANCE X302-7 EEC (24V) All versions < V4.1.3; Siemens SCALANCE X302-7 EEC (24V, coated) All versions < V4.1.3; Siemens SCALANCE X302-7 EEC (2x 230V) All versions < V4.1.3; Siemens SCALANCE X302-7 EEC (2x 230V, coated) All versions < V4.1.3; Siemens SCALANCE X302-7 EEC (2x 24V) All versions < V4.1.3; Siemens SCALANCE X302-7 EEC (2x 24V, coated) All versions < V4.1.3; Siemens SCALANCE X304-2FE All versions < V4.1.3; Siemens SCALANCE X306-1LD FE All versions < V4.1.3; Siemens SCALANCE X307-2 EEC (230V) All versions < V4.1.3; Siemens SCALANCE X307-2 EEC (230V, coated) All versions < V4.1.3; Siemens SCALANCE X307-2 EEC (24V) All versions < V4.1.3; Siemens SCALANCE X307-2 EEC (24V, coated) All versions < V4.1.3; Siemens SCALANCE X307-2 EEC (2x 230V) All versions < V4.1.3; Siemens SCALANCE X307-2 EEC (2x 230V, coated) All versions < V4.1.3; Siemens SCALANCE X307-2 EEC (2x 24V) All versions < V4.1.3; Siemens SCALANCE X307-2 EEC (2x 24V, coated) All versions < V4.1.3; Siemens SCALANCE X307-3 All versions < V4.1.3; Siemens SCALANCE X307-3 All versions < V4.1.3; Siemens SCALANCE X307-3LD All versions < V4.1.3; Siemens SCALANCE X307-3LD All versions < V4.1.3; Siemens SCALANCE X308-2 All versions < V4.1.3; Siemens SCALANCE X308-2 All versions < V4.1.3; Siemens SCALANCE X308-2LD All versions < V4.1.3; Siemens SCALANCE X308-2LD All versions < V4.1.3; Siemens SCALANCE X308-2LH All versions < V4.1.3; Siemens SCALANCE X308-2LH All versions < V4.1.3; Siemens SCALANCE X308-2LH+ All versions < V4.1.3; Siemens SCALANCE X308-2LH+ All versions < V4.1.3; Siemens SCALANCE X308-2M All versions < V4.1.3; Siemens SCALANCE X308-2M All versions < V4.1.3; Siemens SCALANCE X308-2M PoE All versions < V4.1.3; Siemens SCALANCE X308-2M PoE All versions < V4.1.3; Siemens SCALANCE X308-2M TS All versions < V4.1.3; Siemens SCALANCE X308-2M TS All versions < V4.1.3; Siemens SCALANCE X310 All versions < V4.1.3; Siemens SCALANCE X310 All versions < V4.1.3; Siemens SCALANCE X310FE All versions < V4.1.3; Siemens SCALANCE X310FE All versions < V4.1.3; Siemens SCALANCE X320-1 FE All versions < V4.1.3; Siemens SCALANCE X320-1-2LD FE All versions < V4.1.3; Siemens SCALANCE X408-2 All versions < V4.1.3; Siemens SCALANCE XB205-3 (SC) All versions < V4.1; Siemens SCALANCE XB205-3 (SC) All versions < V4.1; Siemens SCALANCE XB205-3 (ST/BFOC) All versions < V4.1; Siemens SCALANCE XB205-3 (ST/BFOC) All versions < V4.1; Siemens SCALANCE XB205-3LD All versions < V4.1; Siemens SCALANCE XB205-3LD All versions < V4.1; Siemens SCALANCE XB208 All versions < V4.1; Siemens SCALANCE XB208 All versions < V4.1; Siemens SCALANCE XB213-3 (SC) All versions < V4.1; Siemens SCALANCE XB213-3 (SC) All versions < V4.1; Siemens SCALANCE XB213-3 (ST/BFOC) All versions < V4.1; Siemens SCALANCE XB213-3 (ST/BFOC) All versions < V4.1; Siemens SCALANCE XB213-3LD All versions < V4.1; Siemens SCALANCE XB213-3LD All versions < V4.1; Siemens SCALANCE XB216 All versions < V4.1; Siemens SCALANCE XB216 All versions < V4.1; Siemens SCALANCE XC206-2 (SC) All versions < V4.1; Siemens SCALANCE XC206-2 (ST/BFOC) All versions < V4.1; Siemens SCALANCE XC206-2SFP All versions < V4.1; Siemens SCALANCE XC206-2SFP EEC All versions < V4.1; Siemens SCALANCE XC206-2SFP G All versions < V4.1; Siemens SCALANCE XC206-2SFP G All versions < V4.1; Siemens SCALANCE XC206-2SFP G EEC All versions < V4.1; Siemens SCALANCE XC208 All versions < V4.1; Siemens SCALANCE XC208EEC All versions < V4.1; Siemens SCALANCE XC208G All versions < V4.1; Siemens SCALANCE XC208G All versions < V4.1; Siemens SCALANCE XC208G EEC All versions < V4.1; Siemens SCALANCE XC216 All versions < V4.1; Siemens SCALANCE XC216-4C All versions < V4.1; Siemens SCALANCE XC216-4C G All versions < V4.1; Siemens SCALANCE XC216-4C G (EIP Def.) All versions < V4.1; Siemens SCALANCE XC216-4C G EEC All versions < V4.1; Siemens SCALANCE XC216EEC All versions < V4.1; Siemens SCALANCE XC224 All versions < V4.1; Siemens SCALANCE XC224-4C G All versions < V4.1; Siemens SCALANCE XC224-4C G (EIP Def.) All versions < V4.1; Siemens SCALANCE XC224-4C G EEC All versions < V4.1; Siemens SCALANCE XF204 All versions < V5.2.6; Siemens SCALANCE XF204 All versions < V4.1; Siemens SCALANCE XF204 DNA All versions < V4.1; Siemens SCALANCE XF204-2 All versions < V5.2.6; Siemens SCALANCE XF204-2BA All versions < V4.1; Siemens SCALANCE XF204-2BA DNA All versions < V4.1; Siemens SCALANCE XF206-1 All versions < V5.2.6; Siemens SCALANCE XF208 All versions < V5.2.6; Siemens SCALANCE XP208 All versions < V4.1; Siemens SCALANCE XP208 All versions < V4.1; Siemens SCALANCE XP208EEC All versions < V4.1; Siemens SCALANCE XP208PoE EEC All versions < V4.1; Siemens SCALANCE XP216 All versions < V4.1; Siemens SCALANCE XP216 All versions < V4.1; Siemens SCALANCE XP216EEC All versions < V4.1; Siemens SCALANCE XP216POE EEC All versions < V4.1; Siemens SCALANCE XR324-12M (230V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-12M (230V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-12M (230V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-12M (230V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-12M (24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-12M (24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-12M (24V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-12M (24V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-12M TS (24V) All versions < V4.1.3; Siemens SCALANCE XR324-12M TS (24V) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (24V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (24V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE (230V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE (230V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE (230V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE (230V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE (24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE (24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE (24V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE (24V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE TS (24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE TS (24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324WG (24 X FE, DC 24V) All versions < V4.1; Siemens SCALANCE XR324WG (24 x FE, AC 230V) All versions < V4.1; Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) All versions < V4.1; Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) All versions < V4.1; Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) All versions < V4.1; Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) All versions < V4.1; Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) All versions < V4.1; Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) All versions < V4.1; Siemens SIPLUS NET SCALANCE X308-2 All versions < V4.1.3; Siemens SIPLUS NET SCALANCE XC206-2 All versions < V4.1; Siemens SIPLUS NET SCALANCE XC206-2SFP All versions < V4.1; Siemens SIPLUS NET SCALANCE XC208 All versions < V4.1; Siemens SIPLUS NET SCALANCE XC216-4C All versions < V4.1
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
9.1 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: High
  • Integrity impact: None
  • Availability impact: High
EPSS
1.33% chance of exploitation in 30 days (percentile 71, 2026-11-26)
CWE
CWE-440
Published
Modified

Description

The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens SCALANCE X204-2All versions < V5.2.6—cvelist
Siemens SCALANCE X204-2FMAll versions < V5.2.6—cvelist
Siemens SCALANCE X204-2LDAll versions < V5.2.6—cvelist
Siemens SCALANCE X204-2LD TSAll versions < V5.2.6—cvelist
Siemens SCALANCE X204-2TSAll versions < V5.2.6—cvelist
Siemens SCALANCE X206-1All versions < V5.2.6—cvelist
Siemens SCALANCE X206-1LDAll versions < V5.2.6—cvelist
Siemens SCALANCE X208All versions < V5.2.6—cvelist
Siemens SCALANCE X208PROAll versions < V5.2.6—cvelist
Siemens SCALANCE X212-2All versions < V5.2.6—cvelist
Siemens SCALANCE X212-2LDAll versions < V5.2.6—cvelist
Siemens SCALANCE X216All versions < V5.2.6—cvelist
Siemens SCALANCE X224All versions < V5.2.6—cvelist
Siemens SCALANCE X302-7 EEC (230V)All versions < V4.1.3—cvelist
Siemens SCALANCE X302-7 EEC (230V, coated)All versions < V4.1.3—cvelist
Siemens SCALANCE X302-7 EEC (24V)All versions < V4.1.3—cvelist
Siemens SCALANCE X302-7 EEC (24V, coated)All versions < V4.1.3—cvelist
Siemens SCALANCE X302-7 EEC (2x 230V)All versions < V4.1.3—cvelist
Siemens SCALANCE X302-7 EEC (2x 230V, coated)All versions < V4.1.3—cvelist
Siemens SCALANCE X302-7 EEC (2x 24V)All versions < V4.1.3—cvelist
Siemens SCALANCE X302-7 EEC (2x 24V, coated)All versions < V4.1.3—cvelist
Siemens SCALANCE X304-2FEAll versions < V4.1.3—cvelist
Siemens SCALANCE X306-1LD FEAll versions < V4.1.3—cvelist
Siemens SCALANCE X307-2 EEC (230V)All versions < V4.1.3—cvelist
Siemens SCALANCE X307-2 EEC (230V, coated)All versions < V4.1.3—cvelist
Siemens SCALANCE X307-2 EEC (24V)All versions < V4.1.3—cvelist
Siemens SCALANCE X307-2 EEC (24V, coated)All versions < V4.1.3—cvelist
Siemens SCALANCE X307-2 EEC (2x 230V)All versions < V4.1.3—cvelist
Siemens SCALANCE X307-2 EEC (2x 230V, coated)All versions < V4.1.3—cvelist
Siemens SCALANCE X307-2 EEC (2x 24V)All versions < V4.1.3—cvelist
Siemens SCALANCE X307-2 EEC (2x 24V, coated)All versions < V4.1.3—cvelist
Siemens SCALANCE X307-3All versions < V4.1.3—cvelist
Siemens SCALANCE X307-3All versions < V4.1.3—cvelist
Siemens SCALANCE X307-3LDAll versions < V4.1.3—cvelist
Siemens SCALANCE X307-3LDAll versions < V4.1.3—cvelist
Siemens SCALANCE X308-2All versions < V4.1.3—cvelist
Siemens SCALANCE X308-2All versions < V4.1.3—cvelist
Siemens SCALANCE X308-2LDAll versions < V4.1.3—cvelist
Siemens SCALANCE X308-2LDAll versions < V4.1.3—cvelist
Siemens SCALANCE X308-2LHAll versions < V4.1.3—cvelist
Siemens SCALANCE X308-2LHAll versions < V4.1.3—cvelist
Siemens SCALANCE X308-2LH+All versions < V4.1.3—cvelist
Siemens SCALANCE X308-2LH+All versions < V4.1.3—cvelist
Siemens SCALANCE X308-2MAll versions < V4.1.3—cvelist
Siemens SCALANCE X308-2MAll versions < V4.1.3—cvelist
Siemens SCALANCE X308-2M PoEAll versions < V4.1.3—cvelist
Siemens SCALANCE X308-2M PoEAll versions < V4.1.3—cvelist
Siemens SCALANCE X308-2M TSAll versions < V4.1.3—cvelist
Siemens SCALANCE X308-2M TSAll versions < V4.1.3—cvelist
Siemens SCALANCE X310All versions < V4.1.3—cvelist
Siemens SCALANCE X310All versions < V4.1.3—cvelist
Siemens SCALANCE X310FEAll versions < V4.1.3—cvelist
Siemens SCALANCE X310FEAll versions < V4.1.3—cvelist
Siemens SCALANCE X320-1 FEAll versions < V4.1.3—cvelist
Siemens SCALANCE X320-1-2LD FEAll versions < V4.1.3—cvelist
Siemens SCALANCE X408-2All versions < V4.1.3—cvelist
Siemens SCALANCE XB205-3 (SC)All versions < V4.1—cvelist
Siemens SCALANCE XB205-3 (SC)All versions < V4.1—cvelist
Siemens SCALANCE XB205-3 (ST/BFOC)All versions < V4.1—cvelist
Siemens SCALANCE XB205-3 (ST/BFOC)All versions < V4.1—cvelist
Siemens SCALANCE XB205-3LDAll versions < V4.1—cvelist
Siemens SCALANCE XB205-3LDAll versions < V4.1—cvelist
Siemens SCALANCE XB208All versions < V4.1—cvelist
Siemens SCALANCE XB208All versions < V4.1—cvelist
Siemens SCALANCE XB213-3 (SC)All versions < V4.1—cvelist
Siemens SCALANCE XB213-3 (SC)All versions < V4.1—cvelist
Siemens SCALANCE XB213-3 (ST/BFOC)All versions < V4.1—cvelist
Siemens SCALANCE XB213-3 (ST/BFOC)All versions < V4.1—cvelist
Siemens SCALANCE XB213-3LDAll versions < V4.1—cvelist
Siemens SCALANCE XB213-3LDAll versions < V4.1—cvelist
Siemens SCALANCE XB216All versions < V4.1—cvelist
Siemens SCALANCE XB216All versions < V4.1—cvelist
Siemens SCALANCE XC206-2 (SC)All versions < V4.1—cvelist
Siemens SCALANCE XC206-2 (ST/BFOC)All versions < V4.1—cvelist
Siemens SCALANCE XC206-2SFPAll versions < V4.1—cvelist
Siemens SCALANCE XC206-2SFP EECAll versions < V4.1—cvelist
Siemens SCALANCE XC206-2SFP GAll versions < V4.1—cvelist
Siemens SCALANCE XC206-2SFP GAll versions < V4.1—cvelist
Siemens SCALANCE XC206-2SFP G EECAll versions < V4.1—cvelist
Siemens SCALANCE XC208All versions < V4.1—cvelist
Siemens SCALANCE XC208EECAll versions < V4.1—cvelist
Siemens SCALANCE XC208GAll versions < V4.1—cvelist
Siemens SCALANCE XC208GAll versions < V4.1—cvelist
Siemens SCALANCE XC208G EECAll versions < V4.1—cvelist
Siemens SCALANCE XC216All versions < V4.1—cvelist
Siemens SCALANCE XC216-4CAll versions < V4.1—cvelist
Siemens SCALANCE XC216-4C GAll versions < V4.1—cvelist
Siemens SCALANCE XC216-4C G (EIP Def.)All versions < V4.1—cvelist
Siemens SCALANCE XC216-4C G EECAll versions < V4.1—cvelist
Siemens SCALANCE XC216EECAll versions < V4.1—cvelist
Siemens SCALANCE XC224All versions < V4.1—cvelist
Siemens SCALANCE XC224-4C GAll versions < V4.1—cvelist
Siemens SCALANCE XC224-4C G (EIP Def.)All versions < V4.1—cvelist
Siemens SCALANCE XC224-4C G EECAll versions < V4.1—cvelist
Siemens SCALANCE XF204All versions < V5.2.6—cvelist
Siemens SCALANCE XF204All versions < V4.1—cvelist
Siemens SCALANCE XF204 DNAAll versions < V4.1—cvelist
Siemens SCALANCE XF204-2All versions < V5.2.6—cvelist
Siemens SCALANCE XF204-2BAAll versions < V4.1—cvelist
Siemens SCALANCE XF204-2BA DNAAll versions < V4.1—cvelist
Siemens SCALANCE XF206-1All versions < V5.2.6—cvelist
Siemens SCALANCE XF208All versions < V5.2.6—cvelist
Siemens SCALANCE XP208All versions < V4.1—cvelist
Siemens SCALANCE XP208All versions < V4.1—cvelist
Siemens SCALANCE XP208EECAll versions < V4.1—cvelist
Siemens SCALANCE XP208PoE EECAll versions < V4.1—cvelist
Siemens SCALANCE XP216All versions < V4.1—cvelist
Siemens SCALANCE XP216All versions < V4.1—cvelist
Siemens SCALANCE XP216EECAll versions < V4.1—cvelist
Siemens SCALANCE XP216POE EECAll versions < V4.1—cvelist
Siemens SCALANCE XR324-12M (230V, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-12M (230V, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-12M (230V, ports on rear)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-12M (230V, ports on rear)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-12M (24V, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-12M (24V, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-12M (24V, ports on rear)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-12M (24V, ports on rear)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-12M TS (24V)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-12M TS (24V)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M EEC (24V, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M EEC (24V, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M EEC (24V, ports on rear)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M EEC (24V, ports on rear)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M PoE (230V, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M PoE (230V, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M PoE (230V, ports on rear)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M PoE (230V, ports on rear)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M PoE (24V, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M PoE (24V, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M PoE (24V, ports on rear)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M PoE (24V, ports on rear)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M PoE TS (24V, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324-4M PoE TS (24V, ports on front)All versions < V4.1.3—cvelist
Siemens SCALANCE XR324WG (24 X FE, DC 24V)All versions < V4.1—cvelist
Siemens SCALANCE XR324WG (24 x FE, AC 230V)All versions < V4.1—cvelist
Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)All versions < V4.1—cvelist
Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)All versions < V4.1—cvelist
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)All versions < V4.1—cvelist
Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)All versions < V4.1—cvelist
Siemens SCALANCE XR328-4C WG (28xGE, AC 230V)All versions < V4.1—cvelist
Siemens SCALANCE XR328-4C WG (28xGE, DC 24V)All versions < V4.1—cvelist
Siemens SIPLUS NET SCALANCE X308-2All versions < V4.1.3—cvelist
Siemens SIPLUS NET SCALANCE XC206-2All versions < V4.1—cvelist
Siemens SIPLUS NET SCALANCE XC206-2SFPAll versions < V4.1—cvelist
Siemens SIPLUS NET SCALANCE XC208All versions < V4.1—cvelist
Siemens SIPLUS NET SCALANCE XC216-4CAll versions < V4.1—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2019-6569. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2019-6569.md
Affected: Siemens SCALANCE X204-2 All versions < V5.2.6; Siemens SCALANCE X204-2FM All versions < V5.2.6; Siemens SCALANCE X204-2LD All versions < V5.2.6; Siemens SCALANCE X204-2LD TS All versions < V5.2.6; Siemens SCALANCE X204-2TS All versions < V5.2.6; Siemens SCALANCE X206-1 All versions < V5.2.6; Siemen…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens SCALANCE X204-2, Siemens SCALANCE X204-2FM, Siemens SCALANCE X204-2LD, Siemens SCALANCE X204-2LD TS, Siemens SCALANCE X204-2TS, Siemens SCALANCE X206-1: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2019-6569 being exploited?

There is no confirmed exploitation: CVE-2019-6569 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.33% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2019-6569?

Critical: CVSS 9.1 (v3.1, scored by NVD). Remote, no login needed.

Which versions are affected by CVE-2019-6569?

Siemens SCALANCE X204-2 All versions < V5.2.6; Siemens SCALANCE X204-2FM All versions < V5.2.6; Siemens SCALANCE X204-2LD All versions < V5.2.6; Siemens SCALANCE X204-2LD TS All versions < V5.2.6; Siemens SCALANCE X204-2TS All versions < V5.2.6; Siemens SCALANCE X206-1 All versions < V5.2.6; Siemens SCALANCE X206-1LD All versions < V5.2.6; Siemens SCALANCE X208 All versions < V5.2.6; Siemens SCALANCE X208PRO All versions < V5.2.6; Siemens SCALANCE X212-2 All versions < V5.2.6; Siemens SCALANCE X212-2LD All versions < V5.2.6; Siemens SCALANCE X216 All versions < V5.2.6; Siemens SCALANCE X224 All versions < V5.2.6; Siemens SCALANCE X302-7 EEC (230V) All versions < V4.1.3; Siemens SCALANCE X302-7 EEC (230V, coated) All versions < V4.1.3; Siemens SCALANCE X302-7 EEC (24V) All versions < V4.1.3; Siemens SCALANCE X302-7 EEC (24V, coated) All versions < V4.1.3; Siemens SCALANCE X302-7 EEC (2x 230V) All versions < V4.1.3; Siemens SCALANCE X302-7 EEC (2x 230V, coated) All versions < V4.1.3; Siemens SCALANCE X302-7 EEC (2x 24V) All versions < V4.1.3; Siemens SCALANCE X302-7 EEC (2x 24V, coated) All versions < V4.1.3; Siemens SCALANCE X304-2FE All versions < V4.1.3; Siemens SCALANCE X306-1LD FE All versions < V4.1.3; Siemens SCALANCE X307-2 EEC (230V) All versions < V4.1.3; Siemens SCALANCE X307-2 EEC (230V, coated) All versions < V4.1.3; Siemens SCALANCE X307-2 EEC (24V) All versions < V4.1.3; Siemens SCALANCE X307-2 EEC (24V, coated) All versions < V4.1.3; Siemens SCALANCE X307-2 EEC (2x 230V) All versions < V4.1.3; Siemens SCALANCE X307-2 EEC (2x 230V, coated) All versions < V4.1.3; Siemens SCALANCE X307-2 EEC (2x 24V) All versions < V4.1.3; Siemens SCALANCE X307-2 EEC (2x 24V, coated) All versions < V4.1.3; Siemens SCALANCE X307-3 All versions < V4.1.3; Siemens SCALANCE X307-3 All versions < V4.1.3; Siemens SCALANCE X307-3LD All versions < V4.1.3; Siemens SCALANCE X307-3LD All versions < V4.1.3; Siemens SCALANCE X308-2 All versions < V4.1.3; Siemens SCALANCE X308-2 All versions < V4.1.3; Siemens SCALANCE X308-2LD All versions < V4.1.3; Siemens SCALANCE X308-2LD All versions < V4.1.3; Siemens SCALANCE X308-2LH All versions < V4.1.3; Siemens SCALANCE X308-2LH All versions < V4.1.3; Siemens SCALANCE X308-2LH+ All versions < V4.1.3; Siemens SCALANCE X308-2LH+ All versions < V4.1.3; Siemens SCALANCE X308-2M All versions < V4.1.3; Siemens SCALANCE X308-2M All versions < V4.1.3; Siemens SCALANCE X308-2M PoE All versions < V4.1.3; Siemens SCALANCE X308-2M PoE All versions < V4.1.3; Siemens SCALANCE X308-2M TS All versions < V4.1.3; Siemens SCALANCE X308-2M TS All versions < V4.1.3; Siemens SCALANCE X310 All versions < V4.1.3; Siemens SCALANCE X310 All versions < V4.1.3; Siemens SCALANCE X310FE All versions < V4.1.3; Siemens SCALANCE X310FE All versions < V4.1.3; Siemens SCALANCE X320-1 FE All versions < V4.1.3; Siemens SCALANCE X320-1-2LD FE All versions < V4.1.3; Siemens SCALANCE X408-2 All versions < V4.1.3; Siemens SCALANCE XB205-3 (SC) All versions < V4.1; Siemens SCALANCE XB205-3 (SC) All versions < V4.1; Siemens SCALANCE XB205-3 (ST/BFOC) All versions < V4.1; Siemens SCALANCE XB205-3 (ST/BFOC) All versions < V4.1; Siemens SCALANCE XB205-3LD All versions < V4.1; Siemens SCALANCE XB205-3LD All versions < V4.1; Siemens SCALANCE XB208 All versions < V4.1; Siemens SCALANCE XB208 All versions < V4.1; Siemens SCALANCE XB213-3 (SC) All versions < V4.1; Siemens SCALANCE XB213-3 (SC) All versions < V4.1; Siemens SCALANCE XB213-3 (ST/BFOC) All versions < V4.1; Siemens SCALANCE XB213-3 (ST/BFOC) All versions < V4.1; Siemens SCALANCE XB213-3LD All versions < V4.1; Siemens SCALANCE XB213-3LD All versions < V4.1; Siemens SCALANCE XB216 All versions < V4.1; Siemens SCALANCE XB216 All versions < V4.1; Siemens SCALANCE XC206-2 (SC) All versions < V4.1; Siemens SCALANCE XC206-2 (ST/BFOC) All versions < V4.1; Siemens SCALANCE XC206-2SFP All versions < V4.1; Siemens SCALANCE XC206-2SFP EEC All versions < V4.1; Siemens SCALANCE XC206-2SFP G All versions < V4.1; Siemens SCALANCE XC206-2SFP G All versions < V4.1; Siemens SCALANCE XC206-2SFP G EEC All versions < V4.1; Siemens SCALANCE XC208 All versions < V4.1; Siemens SCALANCE XC208EEC All versions < V4.1; Siemens SCALANCE XC208G All versions < V4.1; Siemens SCALANCE XC208G All versions < V4.1; Siemens SCALANCE XC208G EEC All versions < V4.1; Siemens SCALANCE XC216 All versions < V4.1; Siemens SCALANCE XC216-4C All versions < V4.1; Siemens SCALANCE XC216-4C G All versions < V4.1; Siemens SCALANCE XC216-4C G (EIP Def.) All versions < V4.1; Siemens SCALANCE XC216-4C G EEC All versions < V4.1; Siemens SCALANCE XC216EEC All versions < V4.1; Siemens SCALANCE XC224 All versions < V4.1; Siemens SCALANCE XC224-4C G All versions < V4.1; Siemens SCALANCE XC224-4C G (EIP Def.) All versions < V4.1; Siemens SCALANCE XC224-4C G EEC All versions < V4.1; Siemens SCALANCE XF204 All versions < V5.2.6; Siemens SCALANCE XF204 All versions < V4.1; Siemens SCALANCE XF204 DNA All versions < V4.1; Siemens SCALANCE XF204-2 All versions < V5.2.6; Siemens SCALANCE XF204-2BA All versions < V4.1; Siemens SCALANCE XF204-2BA DNA All versions < V4.1; Siemens SCALANCE XF206-1 All versions < V5.2.6; Siemens SCALANCE XF208 All versions < V5.2.6; Siemens SCALANCE XP208 All versions < V4.1; Siemens SCALANCE XP208 All versions < V4.1; Siemens SCALANCE XP208EEC All versions < V4.1; Siemens SCALANCE XP208PoE EEC All versions < V4.1; Siemens SCALANCE XP216 All versions < V4.1; Siemens SCALANCE XP216 All versions < V4.1; Siemens SCALANCE XP216EEC All versions < V4.1; Siemens SCALANCE XP216POE EEC All versions < V4.1; Siemens SCALANCE XR324-12M (230V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-12M (230V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-12M (230V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-12M (230V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-12M (24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-12M (24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-12M (24V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-12M (24V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-12M TS (24V) All versions < V4.1.3; Siemens SCALANCE XR324-12M TS (24V) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (24V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (24V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE (230V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE (230V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE (230V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE (230V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE (24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE (24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE (24V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE (24V, ports on rear) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE TS (24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324-4M PoE TS (24V, ports on front) All versions < V4.1.3; Siemens SCALANCE XR324WG (24 X FE, DC 24V) All versions < V4.1; Siemens SCALANCE XR324WG (24 x FE, AC 230V) All versions < V4.1; Siemens SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) All versions < V4.1; Siemens SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) All versions < V4.1; Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) All versions < V4.1; Siemens SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) All versions < V4.1; Siemens SCALANCE XR328-4C WG (28xGE, AC 230V) All versions < V4.1; Siemens SCALANCE XR328-4C WG (28xGE, DC 24V) All versions < V4.1; Siemens SIPLUS NET SCALANCE X308-2 All versions < V4.1.3; Siemens SIPLUS NET SCALANCE XC206-2 All versions < V4.1; Siemens SIPLUS NET SCALANCE XC206-2SFP All versions < V4.1; Siemens SIPLUS NET SCALANCE XC208 All versions < V4.1; Siemens SIPLUS NET SCALANCE XC216-4C All versions < V4.1.

Is there a fix for CVE-2019-6569?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2019-6569?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors