Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2019-6568

HIGH 7.5EPSS 73%

The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attac…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens SIMATIC CP 1604 All versions
  • Anyone running Siemens SIMATIC CP 1616 All versions
  • Anyone running Siemens SIMATIC CP 343-1 Advanced All versions
  • Anyone running Siemens SIMATIC CP 443-1 All versions < V3.3
  • Anyone running Siemens SIMATIC CP 443-1 Advanced All versions < V3.3
  • Anyone running Siemens SIMATIC CP 443-1 OPC UA All versions
  • Anyone running Siemens SIMATIC ET 200pro IM154-8 PN/DP CPU All versions < V3.2.16
  • Anyone running Siemens SIMATIC ET 200pro IM154-8F PN/DP CPU All versions < V3.2.16

Vulnerability facts

Affected
Siemens SIMATIC CP 1604 All versions; Siemens SIMATIC CP 1616 All versions; Siemens SIMATIC CP 343-1 Advanced All versions; Siemens SIMATIC CP 443-1 All versions < V3.3; Siemens SIMATIC CP 443-1 All versions < V3.3; Siemens SIMATIC CP 443-1 Advanced All versions < V3.3; Siemens SIMATIC CP 443-1 OPC UA All versions; Siemens SIMATIC ET 200pro IM154-8 PN/DP CPU All versions < V3.2.16; Siemens SIMATIC ET 200pro IM154-8F PN/DP CPU All versions < V3.2.16; Siemens SIMATIC ET 200pro IM154-8FX PN/DP CPU All versions < V3.2.16; Siemens SIMATIC ET 200S IM151-8 PN/DP CPU All versions < V3.2.16; Siemens SIMATIC ET 200S IM151-8F PN/DP CPU All versions < V3.2.16; Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) All versions < V2.1.6; Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) All versions < V2.7; Siemens SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) All versions < V15.1 Upd4; Siemens SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) All versions < V15.1 Upd4; Siemens SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F All versions < V15.1 Upd4; Siemens SIMATIC IPC DiagMonitor All versions < V5.1.3; Siemens SIMATIC RF182C All versions; Siemens SIMATIC RF185C All versions < V1.1.0; Siemens SIMATIC RF186C All versions < V1.1.0; Siemens SIMATIC RF188C All versions < V1.1.0; Siemens SIMATIC RF600R family All versions < V3.2.1; Siemens SIMATIC RFID 181EIP All versions; Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) All versions < V2.6.1; Siemens SIMATIC S7-1500 Software Controller All versions < V2.7; Siemens SIMATIC S7-300 CPU 314C-2 PN/DP All versions < V3.3.16; Siemens SIMATIC S7-300 CPU 315-2 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-300 CPU 315F-2 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-300 CPU 315T-3 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-300 CPU 317-2 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-300 CPU 317F-2 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-300 CPU 317T-3 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-300 CPU 319-3 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-300 CPU 319F-3 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) All versions; Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) All versions; Siemens SIMATIC S7-PLCSIM Advanced All versions < V2.0 SP1 UPD1; Siemens SIMATIC Teleservice Adapter IE Advanced All versions; Siemens SIMATIC Teleservice Adapter IE Basic All versions; Siemens SIMATIC Teleservice Adapter IE Standard All versions; Siemens SIMATIC WinAC RTX 2010 All versions < V2010 SP3; Siemens SIMATIC WinAC RTX F 2010 All versions < V2010 SP3; Siemens SIMATIC WinCC Runtime Advanced All versions < V15.1 Upd4; Siemens SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants) All versions < V1.1.3; Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants) All versions < V2.1.3; Siemens SINAMICS G130 V4.6 Control Unit All versions; Siemens SINAMICS G130 V4.7 Control Unit All versions; Siemens SINAMICS G130 V4.7 SP1 Control Unit All versions; Siemens SINAMICS G130 V4.8 Control Unit All versions < V4.8 HF6; Siemens SINAMICS G130 V5.1 Control Unit All versions; Siemens SINAMICS G130 V5.1 SP1 Control Unit All versions < V5.1 SP1 HF4; Siemens SINAMICS G150 V4.6 Control Unit All versions; Siemens SINAMICS G150 V4.7 Control Unit All versions; Siemens SINAMICS G150 V4.7 SP1 Control Unit All versions; Siemens SINAMICS G150 V4.8 Control Unit All versions < V4.8 HF6; Siemens SINAMICS G150 V5.1 Control Unit All versions; Siemens SINAMICS G150 V5.1 SP1 Control Unit All versions < V5.1 SP1 HF4; Siemens SINAMICS GH150 V4.7 (Control Unit) All versions; Siemens SINAMICS GH150 V4.8 (Control Unit) All versions < V4.8 SP2 HF9; Siemens SINAMICS GL150 V4.7 (Control Unit) All versions; Siemens SINAMICS GL150 V4.8 (Control Unit) All versions < V4.8 SP2 HF9; Siemens SINAMICS GM150 V4.7 (Control Unit) All versions; Siemens SINAMICS GM150 V4.8 (Control Unit) All versions < V4.8 SP2 HF9; Siemens SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants) All versions; Siemens SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants) All versions; Siemens SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants) All versions; Siemens SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants) All versions < V4.8 HF6; Siemens SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants) All versions; Siemens SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants) All versions < V5.1 SP1 HF4; Siemens SINAMICS S150 V4.6 Control Unit All versions; Siemens SINAMICS S150 V4.7 Control Unit All versions; Siemens SINAMICS S150 V4.7 SP1 Control Unit All versions; Siemens SINAMICS S150 V4.8 Control Unit All versions < V4.8 HF6; Siemens SINAMICS S150 V5.1 Control Unit All versions; Siemens SINAMICS S150 V5.1 SP1 Control Unit All versions < V5.1 SP1 HF4; Siemens SINAMICS S210 All versions < V5.1 SP1 HF8; Siemens SINAMICS SL150 V4.7 (Control Unit) All versions < V4.7 HF33; Siemens SINAMICS SL150 V4.8 (Control Unit) All versions; Siemens SINAMICS SM120 V4.7 (Control Unit) All versions; Siemens SINAMICS SM120 V4.8 (Control Unit) All versions < V4.8 SP2 HF10; Siemens SINAMICS SM150 V4.8 (Control Unit) All versions; Siemens SIPLUS ET 200S IM151-8 PN/DP CPU All versions < V3.2.16; Siemens SIPLUS ET 200S IM151-8F PN/DP CPU All versions < V3.2.16; Siemens SIPLUS NET CP 343-1 Advanced All versions; Siemens SIPLUS NET CP 443-1 All versions < V3.3; Siemens SIPLUS NET CP 443-1 Advanced All versions < V3.3; Siemens SIPLUS S7-300 CPU 314C-2 PN/DP All versions < V3.3.16; Siemens SIPLUS S7-300 CPU 315-2 PN/DP All versions < V3.2.16; Siemens SIPLUS S7-300 CPU 315F-2 PN/DP All versions < V3.2.16; Siemens SIPLUS S7-300 CPU 317-2 PN/DP All versions < V3.2.16; Siemens SIPLUS S7-300 CPU 317F-2 PN/DP All versions < V3.2.16; Siemens SITOP Manager All versions < V1.1; Siemens SITOP PSU8600 All versions < V1.5; Siemens SITOP UPS1600 (incl. SIPLUS variants) All versions < V2.3; Siemens TIM 1531 IRC (incl. SIPLUS NET variants) All versions < V2.1
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
7.5 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:COpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: High
  • E: P
  • RL: O
  • RC: C
EPSS
1.40% chance of exploitation in 30 days (percentile 73, 2026-11-26)
CWE
CWE-125
Published
Modified

Description

The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens SIMATIC CP 1604All versions—cvelist
Siemens SIMATIC CP 1616All versions—cvelist
Siemens SIMATIC CP 343-1 AdvancedAll versions—cvelist
Siemens SIMATIC CP 443-1All versions < V3.3—cvelist
Siemens SIMATIC CP 443-1All versions < V3.3—cvelist
Siemens SIMATIC CP 443-1 AdvancedAll versions < V3.3—cvelist
Siemens SIMATIC CP 443-1 OPC UAAll versions—cvelist
Siemens SIMATIC ET 200pro IM154-8 PN/DP CPUAll versions < V3.2.16—cvelist
Siemens SIMATIC ET 200pro IM154-8F PN/DP CPUAll versions < V3.2.16—cvelist
Siemens SIMATIC ET 200pro IM154-8FX PN/DP CPUAll versions < V3.2.16—cvelist
Siemens SIMATIC ET 200S IM151-8 PN/DP CPUAll versions < V3.2.16—cvelist
Siemens SIMATIC ET 200S IM151-8F PN/DP CPUAll versions < V3.2.16—cvelist
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)All versions < V2.1.6—cvelist
Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)All versions < V2.7—cvelist
Siemens SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants)All versions < V15.1 Upd4—cvelist
Siemens SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants)All versions < V15.1 Upd4—cvelist
Siemens SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900FAll versions < V15.1 Upd4—cvelist
Siemens SIMATIC IPC DiagMonitorAll versions < V5.1.3—cvelist
Siemens SIMATIC RF182CAll versions—cvelist
Siemens SIMATIC RF185CAll versions < V1.1.0—cvelist
Siemens SIMATIC RF186CAll versions < V1.1.0—cvelist
Siemens SIMATIC RF188CAll versions < V1.1.0—cvelist
Siemens SIMATIC RF600R familyAll versions < V3.2.1—cvelist
Siemens SIMATIC RFID 181EIPAll versions—cvelist
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)All versions < V2.6.1—cvelist
Siemens SIMATIC S7-1500 Software ControllerAll versions < V2.7—cvelist
Siemens SIMATIC S7-300 CPU 314C-2 PN/DPAll versions < V3.3.16—cvelist
Siemens SIMATIC S7-300 CPU 315-2 PN/DPAll versions < V3.2.16—cvelist
Siemens SIMATIC S7-300 CPU 315F-2 PN/DPAll versions < V3.2.16—cvelist
Siemens SIMATIC S7-300 CPU 315T-3 PN/DPAll versions < V3.2.16—cvelist
Siemens SIMATIC S7-300 CPU 317-2 PN/DPAll versions < V3.2.16—cvelist
Siemens SIMATIC S7-300 CPU 317F-2 PN/DPAll versions < V3.2.16—cvelist
Siemens SIMATIC S7-300 CPU 317T-3 PN/DPAll versions < V3.2.16—cvelist
Siemens SIMATIC S7-300 CPU 317TF-3 PN/DPAll versions < V3.2.16—cvelist
Siemens SIMATIC S7-300 CPU 319-3 PN/DPAll versions < V3.2.16—cvelist
Siemens SIMATIC S7-300 CPU 319F-3 PN/DPAll versions < V3.2.16—cvelist
Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)All versions—cvelist
Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)All versions—cvelist
Siemens SIMATIC S7-PLCSIM AdvancedAll versions < V2.0 SP1 UPD1—cvelist
Siemens SIMATIC Teleservice Adapter IE AdvancedAll versions—cvelist
Siemens SIMATIC Teleservice Adapter IE BasicAll versions—cvelist
Siemens SIMATIC Teleservice Adapter IE StandardAll versions—cvelist
Siemens SIMATIC WinAC RTX 2010All versions < V2010 SP3—cvelist
Siemens SIMATIC WinAC RTX F 2010All versions < V2010 SP3—cvelist
Siemens SIMATIC WinCC Runtime AdvancedAll versions < V15.1 Upd4—cvelist
Siemens SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants)All versions < V1.1.3—cvelist
Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants)All versions < V2.1.3—cvelist
Siemens SINAMICS G130 V4.6 Control UnitAll versions—cvelist
Siemens SINAMICS G130 V4.7 Control UnitAll versions—cvelist
Siemens SINAMICS G130 V4.7 SP1 Control UnitAll versions—cvelist
Siemens SINAMICS G130 V4.8 Control UnitAll versions < V4.8 HF6—cvelist
Siemens SINAMICS G130 V5.1 Control UnitAll versions—cvelist
Siemens SINAMICS G130 V5.1 SP1 Control UnitAll versions < V5.1 SP1 HF4—cvelist
Siemens SINAMICS G150 V4.6 Control UnitAll versions—cvelist
Siemens SINAMICS G150 V4.7 Control UnitAll versions—cvelist
Siemens SINAMICS G150 V4.7 SP1 Control UnitAll versions—cvelist
Siemens SINAMICS G150 V4.8 Control UnitAll versions < V4.8 HF6—cvelist
Siemens SINAMICS G150 V5.1 Control UnitAll versions—cvelist
Siemens SINAMICS G150 V5.1 SP1 Control UnitAll versions < V5.1 SP1 HF4—cvelist
Siemens SINAMICS GH150 V4.7 (Control Unit)All versions—cvelist
Siemens SINAMICS GH150 V4.8 (Control Unit)All versions < V4.8 SP2 HF9—cvelist
Siemens SINAMICS GL150 V4.7 (Control Unit)All versions—cvelist
Siemens SINAMICS GL150 V4.8 (Control Unit)All versions < V4.8 SP2 HF9—cvelist
Siemens SINAMICS GM150 V4.7 (Control Unit)All versions—cvelist
Siemens SINAMICS GM150 V4.8 (Control Unit)All versions < V4.8 SP2 HF9—cvelist
Siemens SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants)All versions—cvelist
Siemens SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants)All versions—cvelist
Siemens SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants)All versions—cvelist
Siemens SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants)All versions < V4.8 HF6—cvelist
Siemens SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants)All versions—cvelist
Siemens SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants)All versions < V5.1 SP1 HF4—cvelist
Siemens SINAMICS S150 V4.6 Control UnitAll versions—cvelist
Siemens SINAMICS S150 V4.7 Control UnitAll versions—cvelist
Siemens SINAMICS S150 V4.7 SP1 Control UnitAll versions—cvelist
Siemens SINAMICS S150 V4.8 Control UnitAll versions < V4.8 HF6—cvelist
Siemens SINAMICS S150 V5.1 Control UnitAll versions—cvelist
Siemens SINAMICS S150 V5.1 SP1 Control UnitAll versions < V5.1 SP1 HF4—cvelist
Siemens SINAMICS S210All versions < V5.1 SP1 HF8—cvelist
Siemens SINAMICS SL150 V4.7 (Control Unit)All versions < V4.7 HF33—cvelist
Siemens SINAMICS SL150 V4.8 (Control Unit)All versions—cvelist
Siemens SINAMICS SM120 V4.7 (Control Unit)All versions—cvelist
Siemens SINAMICS SM120 V4.8 (Control Unit)All versions < V4.8 SP2 HF10—cvelist
Siemens SINAMICS SM150 V4.8 (Control Unit)All versions—cvelist
Siemens SIPLUS ET 200S IM151-8 PN/DP CPUAll versions < V3.2.16—cvelist
Siemens SIPLUS ET 200S IM151-8F PN/DP CPUAll versions < V3.2.16—cvelist
Siemens SIPLUS NET CP 343-1 AdvancedAll versions—cvelist
Siemens SIPLUS NET CP 443-1All versions < V3.3—cvelist
Siemens SIPLUS NET CP 443-1 AdvancedAll versions < V3.3—cvelist
Siemens SIPLUS S7-300 CPU 314C-2 PN/DPAll versions < V3.3.16—cvelist
Siemens SIPLUS S7-300 CPU 315-2 PN/DPAll versions < V3.2.16—cvelist
Siemens SIPLUS S7-300 CPU 315F-2 PN/DPAll versions < V3.2.16—cvelist
Siemens SIPLUS S7-300 CPU 317-2 PN/DPAll versions < V3.2.16—cvelist
Siemens SIPLUS S7-300 CPU 317F-2 PN/DPAll versions < V3.2.16—cvelist
Siemens SITOP ManagerAll versions < V1.1—cvelist
Siemens SITOP PSU8600All versions < V1.5—cvelist
Siemens SITOP UPS1600 (incl. SIPLUS variants)All versions < V2.3—cvelist
Siemens TIM 1531 IRC (incl. SIPLUS NET variants)All versions < V2.1—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2019-6568. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2019-6568.md
Affected: Siemens SIMATIC CP 1604 All versions; Siemens SIMATIC CP 1616 All versions; Siemens SIMATIC CP 343-1 Advanced All versions; Siemens SIMATIC CP 443-1 All versions < V3.3; Siemens SIMATIC CP 443-1 All versions < V3.3; Siemens SIMATIC CP 443-1 Advanced All versions < V3.3; Siemens SIMATIC CP 443-1 OPC…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens SIMATIC CP 1604, Siemens SIMATIC CP 1616, Siemens SIMATIC CP 343-1 Advanced, Siemens SIMATIC CP 443-1, Siemens SIMATIC CP 443-1 Advanced, Siemens SIMATIC CP 443-1 OPC UA: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2019-6568 being exploited?

There is no confirmed exploitation: CVE-2019-6568 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.40% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2019-6568?

High: CVSS 7.5 (v3.1, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2019-6568?

Siemens SIMATIC CP 1604 All versions; Siemens SIMATIC CP 1616 All versions; Siemens SIMATIC CP 343-1 Advanced All versions; Siemens SIMATIC CP 443-1 All versions < V3.3; Siemens SIMATIC CP 443-1 All versions < V3.3; Siemens SIMATIC CP 443-1 Advanced All versions < V3.3; Siemens SIMATIC CP 443-1 OPC UA All versions; Siemens SIMATIC ET 200pro IM154-8 PN/DP CPU All versions < V3.2.16; Siemens SIMATIC ET 200pro IM154-8F PN/DP CPU All versions < V3.2.16; Siemens SIMATIC ET 200pro IM154-8FX PN/DP CPU All versions < V3.2.16; Siemens SIMATIC ET 200S IM151-8 PN/DP CPU All versions < V3.2.16; Siemens SIMATIC ET 200S IM151-8F PN/DP CPU All versions < V3.2.16; Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) All versions < V2.1.6; Siemens SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) All versions < V2.7; Siemens SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) All versions < V15.1 Upd4; Siemens SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) All versions < V15.1 Upd4; Siemens SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F All versions < V15.1 Upd4; Siemens SIMATIC IPC DiagMonitor All versions < V5.1.3; Siemens SIMATIC RF182C All versions; Siemens SIMATIC RF185C All versions < V1.1.0; Siemens SIMATIC RF186C All versions < V1.1.0; Siemens SIMATIC RF188C All versions < V1.1.0; Siemens SIMATIC RF600R family All versions < V3.2.1; Siemens SIMATIC RFID 181EIP All versions; Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) All versions < V2.6.1; Siemens SIMATIC S7-1500 Software Controller All versions < V2.7; Siemens SIMATIC S7-300 CPU 314C-2 PN/DP All versions < V3.3.16; Siemens SIMATIC S7-300 CPU 315-2 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-300 CPU 315F-2 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-300 CPU 315T-3 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-300 CPU 317-2 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-300 CPU 317F-2 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-300 CPU 317T-3 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-300 CPU 319-3 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-300 CPU 319F-3 PN/DP All versions < V3.2.16; Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) All versions; Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) All versions; Siemens SIMATIC S7-PLCSIM Advanced All versions < V2.0 SP1 UPD1; Siemens SIMATIC Teleservice Adapter IE Advanced All versions; Siemens SIMATIC Teleservice Adapter IE Basic All versions; Siemens SIMATIC Teleservice Adapter IE Standard All versions; Siemens SIMATIC WinAC RTX 2010 All versions < V2010 SP3; Siemens SIMATIC WinAC RTX F 2010 All versions < V2010 SP3; Siemens SIMATIC WinCC Runtime Advanced All versions < V15.1 Upd4; Siemens SIMOCODE pro V Ethernet/IP (incl. SIPLUS variants) All versions < V1.1.3; Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants) All versions < V2.1.3; Siemens SINAMICS G130 V4.6 Control Unit All versions; Siemens SINAMICS G130 V4.7 Control Unit All versions; Siemens SINAMICS G130 V4.7 SP1 Control Unit All versions; Siemens SINAMICS G130 V4.8 Control Unit All versions < V4.8 HF6; Siemens SINAMICS G130 V5.1 Control Unit All versions; Siemens SINAMICS G130 V5.1 SP1 Control Unit All versions < V5.1 SP1 HF4; Siemens SINAMICS G150 V4.6 Control Unit All versions; Siemens SINAMICS G150 V4.7 Control Unit All versions; Siemens SINAMICS G150 V4.7 SP1 Control Unit All versions; Siemens SINAMICS G150 V4.8 Control Unit All versions < V4.8 HF6; Siemens SINAMICS G150 V5.1 Control Unit All versions; Siemens SINAMICS G150 V5.1 SP1 Control Unit All versions < V5.1 SP1 HF4; Siemens SINAMICS GH150 V4.7 (Control Unit) All versions; Siemens SINAMICS GH150 V4.8 (Control Unit) All versions < V4.8 SP2 HF9; Siemens SINAMICS GL150 V4.7 (Control Unit) All versions; Siemens SINAMICS GL150 V4.8 (Control Unit) All versions < V4.8 SP2 HF9; Siemens SINAMICS GM150 V4.7 (Control Unit) All versions; Siemens SINAMICS GM150 V4.8 (Control Unit) All versions < V4.8 SP2 HF9; Siemens SINAMICS S120 V4.6 Control Unit (incl. SIPLUS variants) All versions; Siemens SINAMICS S120 V4.7 Control Unit (incl. SIPLUS variants) All versions; Siemens SINAMICS S120 V4.7 SP1 Control Unit (incl. SIPLUS variants) All versions; Siemens SINAMICS S120 V4.8 Control Unit (incl. SIPLUS variants) All versions < V4.8 HF6; Siemens SINAMICS S120 V5.1 Control Unit (incl. SIPLUS variants) All versions; Siemens SINAMICS S120 V5.1 SP1 Control Unit (incl. SIPLUS variants) All versions < V5.1 SP1 HF4; Siemens SINAMICS S150 V4.6 Control Unit All versions; Siemens SINAMICS S150 V4.7 Control Unit All versions; Siemens SINAMICS S150 V4.7 SP1 Control Unit All versions; Siemens SINAMICS S150 V4.8 Control Unit All versions < V4.8 HF6; Siemens SINAMICS S150 V5.1 Control Unit All versions; Siemens SINAMICS S150 V5.1 SP1 Control Unit All versions < V5.1 SP1 HF4; Siemens SINAMICS S210 All versions < V5.1 SP1 HF8; Siemens SINAMICS SL150 V4.7 (Control Unit) All versions < V4.7 HF33; Siemens SINAMICS SL150 V4.8 (Control Unit) All versions; Siemens SINAMICS SM120 V4.7 (Control Unit) All versions; Siemens SINAMICS SM120 V4.8 (Control Unit) All versions < V4.8 SP2 HF10; Siemens SINAMICS SM150 V4.8 (Control Unit) All versions; Siemens SIPLUS ET 200S IM151-8 PN/DP CPU All versions < V3.2.16; Siemens SIPLUS ET 200S IM151-8F PN/DP CPU All versions < V3.2.16; Siemens SIPLUS NET CP 343-1 Advanced All versions; Siemens SIPLUS NET CP 443-1 All versions < V3.3; Siemens SIPLUS NET CP 443-1 Advanced All versions < V3.3; Siemens SIPLUS S7-300 CPU 314C-2 PN/DP All versions < V3.3.16; Siemens SIPLUS S7-300 CPU 315-2 PN/DP All versions < V3.2.16; Siemens SIPLUS S7-300 CPU 315F-2 PN/DP All versions < V3.2.16; Siemens SIPLUS S7-300 CPU 317-2 PN/DP All versions < V3.2.16; Siemens SIPLUS S7-300 CPU 317F-2 PN/DP All versions < V3.2.16; Siemens SITOP Manager All versions < V1.1; Siemens SITOP PSU8600 All versions < V1.5; Siemens SITOP UPS1600 (incl. SIPLUS variants) All versions < V2.3; Siemens TIM 1531 IRC (incl. SIPLUS NET variants) All versions < V2.1.

Is there a fix for CVE-2019-6568?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2019-6568?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors