# CVE-2019-5637: Beckhoff TwinCAT Profinet Driver Divide-by-Zero Denial of Service

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** HIGH 7.5
- **CVSS:** 7.5 (v3.1, CNA) `CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: None; Integrity impact: None; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** Yes (see exploit references)
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 1.43% (percentile 73, 2026-11-26)
- **CWE:** CWE-369
- **Published:** 2019-11-21T19:16:13.344Z
- **Modified:** 2026-06-17T02:38:00.487Z

## Who should check

- Anyone running Beckhoff TwinCAT 2 \>= 2304, \<= 2304
- Anyone running Beckhoff TwinCAT 3.1 \>= 4204.0, \<= 4204.0

## Description

When Beckhoff TwinCAT is configured to use the Profinet driver, a denial of service of the controller could be reached by sending a malformed UDP packet to the device. This issue affects TwinCAT 2 version 2304 (and prior) and TwinCAT 3.1 version 4204.0 (and prior).

## Affected and fixed versions

- Beckhoff TwinCAT 2: \>= 2304, \<= 2304 (cvelist)
- Beckhoff TwinCAT 3.1: \>= 4204.0, \<= 4204.0 (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2019-5637. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2019-5637.md
Affected: Beckhoff TwinCAT 2 >= 2304, <= 2304; Beckhoff TwinCAT 3.1 >= 4204.0, <= 4204.0
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Beckhoff TwinCAT 2, Beckhoff TwinCAT 3.1: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2019-5637 being exploited?

There is no confirmed exploitation: CVE-2019-5637 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 1.43% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2019-5637?

High: CVSS 7.5 (v3.1, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2019-5637?

Beckhoff TwinCAT 2 \>= 2304, \<= 2304; Beckhoff TwinCAT 3.1 \>= 4204.0, \<= 4204.0.

### Is there a fix for CVE-2019-5637?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2019-5637?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://download.beckhoff.com/download/Document/product-security/Advisories/advisory-2019-007.pdf>
- exploit: <https://blog.rapid7.com/2019/10/08/r7-2019-32-denial-of-service-vulnerabilities-in-beckhoff-twincat-plc-environment-fixed/>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2019-5637>

HTML: <https://flawdb.com/CVE-2019-5637> · JSON: <https://flawdb.com/api/v1/entries/CVE-2019-5637>