Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2019-25720

HIGH 7.1EPSS 6%

Dräger SC Monitoring Devices DoS via Malformed Network Packet

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Dräger SC 6002XL SC 6002XL
  • Anyone running Dräger SC6802XL SC6802XL
  • Anyone running Dräger SC 7000 SC 7000
  • Anyone running Dräger SC8000 SC8000
  • Anyone running Dräger SC90000 XL SC90000 XL

Vulnerability facts

Affected
Dräger SC 6002XL SC 6002XL; Dräger SC6802XL SC6802XL; Dräger SC 7000 SC 7000; Dräger SC8000 SC8000; Dräger SC90000 XL SC90000 XL
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Not remotely exploitable (local or adjacent access needed)
CVSS
7.1 (v4.0, CNA)CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Adjacent network
  • Attack complexity: Low
  • Attack requirements: None
  • Privileges required: None
  • User interaction: None
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: High
  • Confidentiality impact on other systems: None
  • Integrity impact on other systems: None
  • Availability impact on other systems: None
EPSS
0.20% chance of exploitation in 30 days (percentile 6, 2026-11-26)
CWE
CWE-1286
Published
Modified

Description

Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.

Affected and fixed versions

Package / productAffectedFixedSource
Dräger SC 6002XLSC 6002XL—cvelist
Dräger SC6802XLSC6802XL—cvelist
Dräger SC 7000SC 7000—cvelist
Dräger SC8000SC8000—cvelist
Dräger SC90000 XLSC90000 XL—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2019-25720. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2019-25720.md
Affected: Dräger SC 6002XL SC 6002XL; Dräger SC6802XL SC6802XL; Dräger SC 7000 SC 7000; Dräger SC8000 SC8000; Dräger SC90000 XL SC90000 XL
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Dräger SC 6002XL, Dräger SC6802XL, Dräger SC 7000, Dräger SC8000, Dräger SC90000 XL: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2019-25720 being exploited?

There is no confirmed exploitation: CVE-2019-25720 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.20% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2019-25720?

High: CVSS 7.1 (v4.0, scored by CNA). Not remotely exploitable (local or adjacent access needed).

Which versions are affected by CVE-2019-25720?

Dräger SC 6002XL SC 6002XL; Dräger SC6802XL SC6802XL; Dräger SC 7000 SC 7000; Dräger SC8000 SC8000; Dräger SC90000 XL SC90000 XL.

Is there a fix for CVE-2019-25720?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2019-25720?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors