Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2019-25402

MEDIUM 5.1PoCEPSS 66%

Comodo Dome Firewall 2.7.0 Cross-Site Scripting via hotspot_permanent_users

Also known as CVE-2019-25403, CVE-2019-25404, CVE-2019-25405, CVE-2019-25406, CVE-2019-25407, CVE-2019-25408, CVE-2019-25409, CVE-2019-25410, CVE-2019-25411, CVE-2019-25412, CVE-2019-25413, CVE-2019-25414, CVE-2019-25415, CVE-2019-25416, CVE-2019-25417, CVE-2019-25418, CVE-2019-25419, CVE-2019-25420, CVE-2019-25421, CVE-2019-25422, CVE-2019-25423, CVE-2019-25424, CVE-2019-25425, CVE-2019-25426, CVE-2019-25427, CVE-2019-25428, CVE-2019-25429, CVE-2019-25430, EDB-46408

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Comodo Dome Firewall 2.7.0

Vulnerability facts

Affected
Comodo Dome Firewall 2.7.0
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
Yes: see the exploit references below
Remote exploitation
Remote, no login needed
CVSS
5.1 (v4.0, CNA)CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:NOpen in CVSS calculator
Show all 11 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Attack requirements: None
  • Privileges required: None
  • User interaction: Active
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: None
  • Confidentiality impact on other systems: Low
  • Integrity impact on other systems: Low
  • Availability impact on other systems: None
EPSS
1.12% chance of exploitation in 30 days (percentile 66, 2026-11-26)
CWE
CWE-79
Published
Modified

Description

Comodo Dome Firewall 2.7.0 contains a reflected cross-site scripting vulnerability that allows attackers to inject malicious scripts by submitting unsanitized input to the hotspot_permanent_users endpoint. Attackers can send POST requests with JavaScript payloads in the MACADDRESSES parameter to execute arbitrary scripts in users' browsers.

Affected and fixed versions

Package / productAffectedFixedSource
Comodo Dome Firewall2.7.0—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2019-25402. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2019-25402.md
Affected: Comodo Dome Firewall 2.7.0
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Comodo Dome Firewall: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

Other

FAQ

Is CVE-2019-25402 being exploited?

There is no confirmed exploitation: CVE-2019-25402 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 1.12% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2019-25402?

Medium: CVSS 5.1 (v4.0, scored by CNA). Remote, no login needed. A user has to take an action, such as opening a link, for the attack to work.

Which versions are affected by CVE-2019-25402?

Comodo Dome Firewall 2.7.0.

Is there a fix for CVE-2019-25402?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2019-25402?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors