# CVE-2019-20461: An issue was discovered on Alecto IVM-100 2019-11-12 devices. The device uses a custom UDP protocol to start and contro…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** CRITICAL 9.8
- **CVSS:** 9.8 (v3.1, CNA) `CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: High; Integrity impact: High; Availability impact: High
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 0.89% (percentile 57, 2026-11-26)
- **CWE:** CWE-295
- **Published:** 2024-11-07T00:00:00.000Z
- **Modified:** 2026-06-17T02:30:30.097Z

## Who should check

- Anyone running n/a (versions: see the vendor advisory)
- Anyone running alecto ivm-100\_firmware 2019-11-12

## Description

An issue was discovered on Alecto IVM-100 2019-11-12 devices. The device uses a custom UDP protocol to start and control video and audio services. The protocol has been partially reverse engineered. Based upon the reverse engineering, no password or username is ever transferred over this protocol. Thus, one can set up the camera connection feed with only the encoded UID. It is possible to set up sessions with the camera over the Internet by using the encoded UID and the custom UDP protocol, because authentication happens at the client side.

## Affected and fixed versions

- n/a: see vendor advisory (nvd)
- alecto ivm-100\_firmware: 2019-11-12 (nvd)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2019-20461. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2019-20461.md
Affected: n/a; alecto ivm-100_firmware 2019-11-12
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for n/a, alecto ivm-100_firmware: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2019-20461 being exploited?

There is no confirmed exploitation: CVE-2019-20461 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.89% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2019-20461?

Critical: CVSS 9.8 (v3.1, scored by CNA). Remote, no login needed.

### Which versions are affected by CVE-2019-20461?

n/a; alecto ivm-100\_firmware 2019-11-12.

### Is there a fix for CVE-2019-20461?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2019-20461?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- other: <https://www.alecto.nl/>
- other: <https://seclists.org/fulldisclosure/2024/Jul/14>
- other: <http://seclists.org/fulldisclosure/2024/Jul/14>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2019-20461>

HTML: <https://flawdb.com/CVE-2019-20461> · JSON: <https://flawdb.com/api/v1/entries/CVE-2019-20461>