Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2019-19279

HIGH 7.5EPSS 76%

A vulnerability has been identified in SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communicatio…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens AG SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules All versions

Vulnerability facts

Affected
Siemens AG SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules All versions
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
7.5 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: High
EPSS
1.59% chance of exploitation in 30 days (percentile 76, 2026-11-26)
CWE
CWE-20
Published
Modified

Description

A vulnerability has been identified in SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules (All versions). Specially crafted packets sent to port 50000/UDP of the EN100 Ethernet communication modules could cause a Denial-of-Service of the affected device. A manual reboot is required to recover the service of the device. At the time of advisory publication no public exploitation of this security vulnerability was known to Siemens.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens AG SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modulesAll versions—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2019-19279. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2019-19279.md
Affected: Siemens AG SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules All versions
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens AG SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2019-19279 being exploited?

There is no confirmed exploitation: CVE-2019-19279 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.59% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2019-19279?

High: CVSS 7.5 (v3.1, scored by NVD). Remote, no login needed.

Which versions are affected by CVE-2019-19279?

Siemens AG SIPROTEC 4 and SIPROTEC Compact relays equipped with EN100 Ethernet communication modules All versions.

Is there a fix for CVE-2019-19279?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2019-19279?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors