CVE-2019-19276
A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) All versions < V16 Update 4
- Anyone running Siemens SIMATIC HMI KTP Mobile Panels All versions < V16 Update 4
Vulnerability facts
- Affected
- Siemens SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) All versions < V16 Update 4; Siemens SIMATIC HMI KTP Mobile Panels All versions < V16 Update 4
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 5.3 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:LOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: Low
- EPSS
- 1.02% chance of exploitation in 30 days (percentile 63, 2026-11-26)
- CWE
- CWE-787
- Modified
Description
A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2019-19276. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2019-19276.md Affected: Siemens SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) All versions < V16 Update 4; Siemens SIMATIC HMI KTP Mobile Panels All versions < V16 Update 4 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants), Siemens SIMATIC HMI KTP Mobile Panels: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2019-19276 being exploited?
There is no confirmed exploitation: CVE-2019-19276 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.02% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2019-19276?
Medium: CVSS 5.3 (v3.1, scored by NVD). Remote, no login needed.
Which versions are affected by CVE-2019-19276?
Siemens SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) All versions < V16 Update 4; Siemens SIMATIC HMI KTP Mobile Panels All versions < V16 Update 4.
Is there a fix for CVE-2019-19276?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2019-19276?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.