CVE-2019-1861
Cisco Industrial Network Director Remote Code Execution Vulnerability
Mitigation
- Upgrade Cisco Industrial Network Director to 1.6.0 or later.
Who should check
- Anyone running Cisco Industrial Network Director >= unspecified, < 1.6.0
Vulnerability facts
- Affected
- Cisco Industrial Network Director >= unspecified, < 1.6.0
- Fixed in
- Cisco Industrial Network Director 1.6.0
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, login needed
- CVSS
- 7.2 (v3.0, CNA)CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: High
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 4.30% chance of exploitation in 30 days (percentile 92, 2026-11-26)
- CWE
- CWE-20
- Modified
Description
A vulnerability in the software update feature of Cisco Industrial Network Director could allow an authenticated, remote attacker to execute arbitrary code. The vulnerability is due to improper validation of files uploaded to the affected application. An attacker could exploit this vulnerability by authenticating to the affected system using administrator privileges and uploading an arbitrary file. A successful exploit could allow the attacker to execute arbitrary code with elevated privileges.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Cisco Industrial Network Director | >= unspecified, < 1.6.0 | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2019-1861. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2019-1861.md Affected: Cisco Industrial Network Director >= unspecified, < 1.6.0 Fixed in: Cisco Industrial Network Director 1.6.0 Steps: 1. Search this machine and project for Cisco Industrial Network Director: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2019-1861 being exploited?
There is no confirmed exploitation: CVE-2019-1861 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 4.30% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2019-1861?
High: CVSS 7.2 (v3.0, scored by CNA). Remote, login needed.
Which versions are affected by CVE-2019-1861?
Cisco Industrial Network Director >= unspecified, < 1.6.0.
Is there a fix for CVE-2019-1861?
Yes. Fixed in Cisco Industrial Network Director 1.6.0. Upgrade Cisco Industrial Network Director to 1.6.0 or later.
How do I check if I'm affected by CVE-2019-1861?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.