Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2019-18336

HIGH 7.5EPSS 78%

A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All ve…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running Siemens AG SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) All versions < V3.X.17
  • Anyone running Siemens AG SIMATIC TDC CP51M1 All versions < V1.1.8
  • Anyone running Siemens AG SIMATIC TDC CPU555 All versions < V1.1.1
  • Anyone running Siemens AG SINUMERIK 840D sl All versions < V4.8.6
  • Anyone running Siemens AG SINUMERIK 840D sl All versions < V4.94

Vulnerability facts

Affected
Siemens AG SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) All versions < V3.X.17; Siemens AG SIMATIC TDC CP51M1 All versions < V1.1.8; Siemens AG SIMATIC TDC CPU555 All versions < V1.1.1; Siemens AG SINUMERIK 840D sl All versions < V4.8.6; Siemens AG SINUMERIK 840D sl All versions < V4.94
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
None known
Remote exploitation
Remote, no login needed
CVSS
7.5 (v3.1, CNA)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: None
  • Integrity impact: None
  • Availability impact: High
EPSS
1.72% chance of exploitation in 30 days (percentile 78, 2026-11-26)
CWE
CWE-400
Published
Modified

Description

A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V3.X.17), SIMATIC TDC CP51M1 (All versions < V1.1.8), SIMATIC TDC CPU555 (All versions < V1.1.1), SINUMERIK 840D sl (All versions < V4.8.6), SINUMERIK 840D sl (All versions < V4.94). Specially crafted packets sent to port 102/tcp (Profinet) could cause the affected device to go into defect mode. A restart is required in order to recover the system. Successful exploitation requires an attacker to have network access to port 102/tcp, with no authentication. No user interation is required. At the time of advisory publication no public exploitation of this security vulnerability was known.

Affected and fixed versions

Package / productAffectedFixedSource
Siemens AG SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)All versions < V3.X.17—cvelist
Siemens AG SIMATIC TDC CP51M1All versions < V1.1.8—cvelist
Siemens AG SIMATIC TDC CPU555All versions < V1.1.1—cvelist
Siemens AG SINUMERIK 840D slAll versions < V4.8.6—cvelist
Siemens AG SINUMERIK 840D slAll versions < V4.94—cvelist

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2019-18336. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2019-18336.md
Affected: Siemens AG SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) All versions < V3.X.17; Siemens AG SIMATIC TDC CP51M1 All versions < V1.1.8; Siemens AG SIMATIC TDC CPU555 All versions < V1.1.1; Siemens AG SINUMERIK 840D sl All versions < V4.8.6; Siemens AG SINUMERIK 840D sl All …
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens AG SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants), Siemens AG SIMATIC TDC CP51M1, Siemens AG SIMATIC TDC CPU555, Siemens AG SINUMERIK 840D sl: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2019-18336 being exploited?

There is no confirmed exploitation: CVE-2019-18336 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.72% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2019-18336?

High: CVSS 7.5 (v3.1, scored by CNA). Remote, no login needed.

Which versions are affected by CVE-2019-18336?

Siemens AG SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) All versions < V3.X.17; Siemens AG SIMATIC TDC CP51M1 All versions < V1.1.8; Siemens AG SIMATIC TDC CPU555 All versions < V1.1.1; Siemens AG SINUMERIK 840D sl All versions < V4.8.6; Siemens AG SINUMERIK 840D sl All versions < V4.94.

Is there a fix for CVE-2019-18336?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2019-18336?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.