CVE-2019-1590
Cisco Nexus 9000 Series Fabric Switches Application Centric Infrastructure Mode Insecure Fabric Authentication Vulnerability
Mitigation
- Upgrade Cisco NX-OS Software for Nexus 9000 Series Fabric Switches ACI Mode to 14.1(1i) or later.
Who should check
- Anyone running Cisco NX-OS Software for Nexus 9000 Series Fabric Switches ACI Mode >= unspecified, < 14.1(1i)
Vulnerability facts
- Affected
- Cisco NX-OS Software for Nexus 9000 Series Fabric Switches ACI Mode >= unspecified, < 14.1(1i)
- Fixed in
- Cisco NX-OS Software for Nexus 9000 Series Fabric Switches ACI Mode 14.1(1i)
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 8.1 (v3.0, CNA)CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: High
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: High
- Integrity impact: High
- Availability impact: High
- EPSS
- 0.99% chance of exploitation in 30 days (percentile 61, 2026-11-26)
- CWE
- CWE-295
- Modified
Description
A vulnerability in the Transport Layer Security (TLS) certificate validation functionality of Cisco Nexus 9000 Series Application Centric Infrastructure (ACI) Mode Switch Software could allow an unauthenticated, remote attacker to perform insecure TLS client authentication on an affected device. The vulnerability is due to insufficient TLS client certificate validations for certificates sent between the various components of an ACI fabric. An attacker who has possession of a certificate that is trusted by the Cisco Manufacturing CA and the corresponding private key could exploit this vulnerability by presenting a valid certificate while attempting to connect to the targeted device. An exploit could allow the attacker to gain full control of all other components within the ACI fabric of an affected device.
Affected and fixed versions
| Package / product | Affected | Fixed | Source |
|---|---|---|---|
| Cisco NX-OS Software for Nexus 9000 Series Fabric Switches ACI Mode | >= unspecified, < 14.1(1i) | — | cvelist |
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2019-1590. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2019-1590.md Affected: Cisco NX-OS Software for Nexus 9000 Series Fabric Switches ACI Mode >= unspecified, < 14.1(1i) Fixed in: Cisco NX-OS Software for Nexus 9000 Series Fabric Switches ACI Mode 14.1(1i) Steps: 1. Search this machine and project for Cisco NX-OS Software for Nexus 9000 Series Fabric Switches ACI Mode: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
FAQ
Is CVE-2019-1590 being exploited?
There is no confirmed exploitation: CVE-2019-1590 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 0.99% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2019-1590?
High: CVSS 8.1 (v3.0, scored by CNA). Remote, no login needed. The attack needs conditions outside the attacker's control, which makes it harder.
Which versions are affected by CVE-2019-1590?
Cisco NX-OS Software for Nexus 9000 Series Fabric Switches ACI Mode >= unspecified, < 14.1(1i).
Is there a fix for CVE-2019-1590?
Yes. Fixed in Cisco NX-OS Software for Nexus 9000 Series Fabric Switches ACI Mode 14.1(1i). Upgrade Cisco NX-OS Software for Nexus 9000 Series Fabric Switches ACI Mode to 14.1(1i) or later.
How do I check if I'm affected by CVE-2019-1590?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.