Skip to content
FlawDB
Sign in
Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

CVE-2019-14356

MEDIUM 5.3PoCEPSS 68%

On Coldcard MK1 and MK2 devices, a side channel for the row-based OLED display was found. The power consumption of each…

Mitigation

  • No fix listed yet: follow the vendor advisory.

Who should check

  • Anyone running n/a (versions: see the vendor advisory)

Vulnerability facts

Affected
n/a
Fixed in
No fix listed yet
Exploited in the wild
Not in CISA KEV
Public exploit / PoC
Yes: see the exploit references below
Remote exploitation
Remote, no login needed
CVSS
5.3 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:NOpen in CVSS calculator
Show all 8 CVSS metrics
  • Attack vector: Network
  • Attack complexity: Low
  • Privileges required: None
  • User interaction: None
  • Scope: Unchanged
  • Confidentiality impact: Low
  • Integrity impact: None
  • Availability impact: None
EPSS
1.20% chance of exploitation in 30 days (percentile 68, 2026-11-26)
CWE
CWE-203
Published
Modified

Description

On Coldcard MK1 and MK2 devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover confidential secrets such as the PIN and BIP39 mnemonic. In other words, the side channel is relevant only if the attacker has enough control over the device's USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data. On Coldcard MK1 and MK2 devices, a side channel for the row-based OLED display was found. The power consumption of each row-based display cycle depends on the number of illuminated pixels, allowing a partial recovery of display contents. For example, a hardware implant in the USB cable might be able to leverage this behavior to recover confidential secrets such as the PIN and BIP39 mnemonic. In other words, the side channel is relevant only if the attacker has enough control over the device's USB connection to make power-consumption measurements at a time when secret data is displayed. The side channel is not relevant in other circumstances, such as a stolen device that is not currently displaying secret data. NOTE: At Coinkite, we’ve already mitigated it, even though we feel strongly that it is not a legitimate issue. In our opinion, it is both unproven (might not even work) and also completely impractical—even if it could be made to work perfectly

Affected and fixed versions

Package / productAffectedFixedSource
n/a——nvd

Check your systems with an agent

Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.

Check whether anything I run is affected by CVE-2019-14356. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2019-14356.md
Affected: n/a
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for n/a: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.

References

FAQ

Is CVE-2019-14356 being exploited?

There is no confirmed exploitation: CVE-2019-14356 is not in the CISA Known Exploited Vulnerabilities catalog. Public exploit code or a proof of concept is available. EPSS estimates a 1.20% chance of exploitation in the next 30 days (as of 2026-11-26).

How serious is CVE-2019-14356?

Medium: CVSS 5.3 (v3.1, scored by NVD). Remote, no login needed.

Which versions are affected by CVE-2019-14356?

n/a.

Is there a fix for CVE-2019-14356?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

How do I check if I'm affected by CVE-2019-14356?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

Sponsors