# CVE-2019-13944: A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 618…

> Archived entry. Full-text search covers entries since 2026-11-10; exact IDs work for all years.

- **Severity:** MEDIUM 5.3
- **CVSS:** 5.3 (v3.1, NVD) `CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N`
- **CVSS metrics:** Attack vector: Network; Attack complexity: Low; Privileges required: None; User interaction: None; Scope: Unchanged; Confidentiality impact: Low; Integrity impact: None; Availability impact: None
- **Exploited in the wild:** Not in CISA KEV
- **Public exploit / PoC:** None known
- **Remote exploitation:** Remote, no login needed
- **EPSS:** 1.60% (percentile 76, 2026-11-26)
- **CWE:** CWE-23
- **Published:** 2019-12-12T19:08:46.000Z
- **Modified:** 2026-06-17T02:17:27.913Z

## Who should check

- Anyone running Siemens AG EN100 Ethernet module DNP3 variant All versions
- Anyone running Siemens AG EN100 Ethernet module IEC 61850 variant All versions \< V4.37
- Anyone running Siemens AG EN100 Ethernet module IEC104 variant All versions
- Anyone running Siemens AG EN100 Ethernet module Modbus TCP variant All versions
- Anyone running Siemens AG EN100 Ethernet module PROFINET IO variant All versions

## Description

A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \< V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). A vulnerability in the integrated web server of the affected devices could allow unauthorized attackers to obtain sensitive information about the device, including logs and configurations. At the time of advisory publication no public exploitation of this security vulnerability was known.

## Affected and fixed versions

- Siemens AG EN100 Ethernet module DNP3 variant: All versions (cvelist)
- Siemens AG EN100 Ethernet module IEC 61850 variant: All versions \< V4.37 (cvelist)
- Siemens AG EN100 Ethernet module IEC104 variant: All versions (cvelist)
- Siemens AG EN100 Ethernet module Modbus TCP variant: All versions (cvelist)
- Siemens AG EN100 Ethernet module PROFINET IO variant: All versions (cvelist)

## Mitigation

- No fix listed yet: follow the vendor advisory.

## Check your systems with an agent

Paste this into a coding agent:

```text
Check whether anything I run is affected by CVE-2019-13944. Work read-only: do not install, upgrade, delete or change anything.

Details: https://flawdb.com/CVE-2019-13944.md
Affected: Siemens AG EN100 Ethernet module DNP3 variant All versions; Siemens AG EN100 Ethernet module IEC 61850 variant All versions < V4.37; Siemens AG EN100 Ethernet module IEC104 variant All versions; Siemens AG EN100 Ethernet module Modbus TCP variant All versions; Siemens AG EN100 Ethernet module PROFI…
Fixed in: no fixed version listed yet

Steps:
1. Search this machine and project for Siemens AG EN100 Ethernet module DNP3 variant, Siemens AG EN100 Ethernet module IEC 61850 variant, Siemens AG EN100 Ethernet module IEC104 variant, Siemens AG EN100 Ethernet module Modbus TCP variant, Siemens AG EN100 Ethernet module PROFINET IO variant: dependency manifests and lockfiles, installed packages, container images and running services.
2. For each match, note the installed version and whether it is inside the affected range.
3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
```

## FAQ

### Is CVE-2019-13944 being exploited?

There is no confirmed exploitation: CVE-2019-13944 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.60% chance of exploitation in the next 30 days (as of 2026-11-26).

### How serious is CVE-2019-13944?

Medium: CVSS 5.3 (v3.1, scored by NVD). Remote, no login needed.

### Which versions are affected by CVE-2019-13944?

Siemens AG EN100 Ethernet module DNP3 variant All versions; Siemens AG EN100 Ethernet module IEC 61850 variant All versions \< V4.37; Siemens AG EN100 Ethernet module IEC104 variant All versions; Siemens AG EN100 Ethernet module Modbus TCP variant All versions; Siemens AG EN100 Ethernet module PROFINET IO variant All versions.

### Is there a fix for CVE-2019-13944?

No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.

### How do I check if I'm affected by CVE-2019-13944?

Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.

## References

- vendor: <https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf>
- other: <https://www.us-cert.gov/ics/advisories/icsa-19-344-07>

## Attribution

- CVE Program: CVE® is a registered trademark of The MITRE Corporation. CVE records © 1999–2026 The MITRE Corporation. <https://www.cve.org/Legal/TermsOfUse>
- NVD: This product uses data from the NVD API but is not endorsed or certified by the NVD. <https://nvd.nist.gov/vuln/detail/CVE-2019-13944>

HTML: <https://flawdb.com/CVE-2019-13944> · JSON: <https://flawdb.com/api/v1/entries/CVE-2019-13944>
