CVE-2019-13925
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >=…
Mitigation
- No fix listed yet: follow the vendor advisory.
Who should check
- Anyone running Siemens SCALANCE S602 All versions >= V3.0 and < V4.1
- Anyone running Siemens SCALANCE S612 All versions >= V3.0 and < V4.1
- Anyone running Siemens SCALANCE S623 All versions >= V3.0 and < V4.1
- Anyone running Siemens SCALANCE S627-2M All versions >= V3.0 and < V4.1
Vulnerability facts
- Affected
- Siemens SCALANCE S602 All versions >= V3.0 and < V4.1; Siemens SCALANCE S612 All versions >= V3.0 and < V4.1; Siemens SCALANCE S623 All versions >= V3.0 and < V4.1; Siemens SCALANCE S627-2M All versions >= V3.0 and < V4.1
- Fixed in
- No fix listed yet
- Exploited in the wild
- Not in CISA KEV
- Public exploit / PoC
- None known
- Remote exploitation
- Remote, no login needed
- CVSS
- 7.5 (v3.1, NVD)CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HOpen in CVSS calculator
Show all 8 CVSS metrics
- Attack vector: Network
- Attack complexity: Low
- Privileges required: None
- User interaction: None
- Scope: Unchanged
- Confidentiality impact: None
- Integrity impact: None
- Availability impact: High
- EPSS
- 1.45% chance of exploitation in 30 days (percentile 74, 2026-11-26)
- CWE
- CWE-400
- Modified
Description
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server.
Affected and fixed versions
Check your systems with an agent
Paste this into Claude Code, Cursor or another coding agent. It only reads; it changes nothing.
Check whether anything I run is affected by CVE-2019-13925. Work read-only: do not install, upgrade, delete or change anything. Details: https://flawdb.com/CVE-2019-13925.md Affected: Siemens SCALANCE S602 All versions >= V3.0 and < V4.1; Siemens SCALANCE S612 All versions >= V3.0 and < V4.1; Siemens SCALANCE S623 All versions >= V3.0 and < V4.1; Siemens SCALANCE S627-2M All versions >= V3.0 and < V4.1 Fixed in: no fixed version listed yet Steps: 1. Search this machine and project for Siemens SCALANCE S602, Siemens SCALANCE S612, Siemens SCALANCE S623, Siemens SCALANCE S627-2M: dependency manifests and lockfiles, installed packages, container images and running services. 2. For each match, note the installed version and whether it is inside the affected range. 3. Report a table: location, installed version, affected (yes / no / unsure), evidence. If affected, say which fixed version or mitigation from the details link applies, but don't apply it.
References
Vendor advisories
FAQ
Is CVE-2019-13925 being exploited?
There is no confirmed exploitation: CVE-2019-13925 is not in the CISA Known Exploited Vulnerabilities catalog. No public exploit code is known. EPSS estimates a 1.45% chance of exploitation in the next 30 days (as of 2026-11-26).
How serious is CVE-2019-13925?
High: CVSS 7.5 (v3.1, scored by NVD). Remote, no login needed.
Which versions are affected by CVE-2019-13925?
Siemens SCALANCE S602 All versions >= V3.0 and < V4.1; Siemens SCALANCE S612 All versions >= V3.0 and < V4.1; Siemens SCALANCE S623 All versions >= V3.0 and < V4.1; Siemens SCALANCE S627-2M All versions >= V3.0 and < V4.1.
Is there a fix for CVE-2019-13925?
No fixed version is listed in the sources yet. No fix listed yet: follow the vendor advisory.
How do I check if I'm affected by CVE-2019-13925?
Find where you use the affected software (dependency lockfiles, installed packages, container images, servers) and compare the installed version with the affected range above. The agent prompt on this page does this read-only.